|
Facilità d'uso
The actual display shows only that area that is being adjusted or used. Fig. 5 Display Fig. 1 Indoor Unit 1Air Filter 2Air Intake Grille 3Air Flow Direction Flaps Fig. 2 Outdoor Unit 4Air intake 5Air outlet Fig. 4 Remote Controller 6START/STOP Button 7Operation Lamp 8ENERGY SAVE Button 9DAY OFF Button 0ENERGY SAVE Lamp AZONE Control Button BSET Button CZONE Control Lamp DAIR FLOW DIRECTION SWING Button EAIR FLOW DIRECTION SWING Lamp FAIR FLOW DIRECTION SET Button GCLOCK ADJUST Button HTIMER MODE Button ISET TIME Button JTEMP./DAY Button MRemote Controller Display (Fig. 5) NTimer Mode Display OClock Display (CLOCK/TIMER) PSet Temperature Display (TEMP.) QFan Speed Display ROperation Mode Display SDEFROST Display TTEST Display KFAN CONTROL Button LMASTER CONTROL Button En-2 PREPARATION Set the Current Time and Day 1 1 Press the CLOCK ADJUST button for more than three seconds. 2 2 Press the TEMP./DAY button and set the day. ^: Use to advance the day forward. Ў: Use to turn the day back. The day is indicated by a code number from 1 to 7, as shown in the table below. Set to the number that corresponds to the current day. DAY CODE 1 2 3 4 5 6 7 DAY OF THE WEEK MON TUE WED THU FRI SAT SUN TIMER MODE ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL ENERGY SAVE AM CLOCK DAY 3 21 3 3 Press the SET TIME button and set the time. ^: Use to advance the time forward. Ў: Use to turn the time back. (Press once to move the time 1 minute; hold down and the time will move 10 minutes at a time.) 4 4 Press the CLOCK ADJUST button again. This registers the new day and time values. The day display goes off, and the time display stops flashing. AM CLOCK Example: Set the time to 9:31. OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Select Mode Operation 1 1 Press the START/STOP button. The unit will start and the remote controller’s operation lamp (green) will light up. 2 2 Press the MASTER CONTROL button to select the de sired mode. sAUTO s *HEAT COOL t FAN t Example: When set to AUTO TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE °F NON STOP AM CLOCK AUTO1 2 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF °F NON STOP AM CLOCK AUTO Example: When set to 84 °F En-3 OPERATION Instructions relating to heating(*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Set the Fan Speed Press the FAN CONTROL button to select the fan speed. sss s AUTO HIGH MED LOW When set to AUTO: * Heating Cooling Fan : : : Fan operates so as to optimally circulate warmed air. However, the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low. As the room temperature approaches that of the thermostat setting, the fan speed becomes slower. The fan alternately turns on and off; when on, the fan runs at the low fan speed. The fan will operate a...
Questo manuale è adatto anche per i modelli :Condizionatori - AOU18RC (708.5 kb)
Condizionatori - AUU36RC (708.5 kb)
Condizionatori - AOU18RC (708.5 kb)
Condizionatori - AOU24RC (708.5 kb)