Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Kenwood, Modello XD-8501

Produttore : Kenwood
File Size : 2.13 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


(DP-MH5 only) For the systems including the DP-H5: Program other tracks by repeating steps 2 and 3 for each. 3Press the P.MODE key to enter the selection in memory. PTY SEARCH 2 31 5 64 8 97 0 +10 Go to step 2 within 8 seconds. 2Enter the track No. DISC SKIP Go to step 3 within 8 seconds. For the systems including the DP-MH5: If you program tracks from more than one CD, repeat steps 1 to 3 for each. To check the edited contents Y To clear the edited contents Y Blinks CCRS REC / ARM OThe recording level and bias will be adjusted automatically in approx. 60 seconds (variable depending on CD contents), after which recording CCRS starts. OFor the systems including DP-MH5: In editing from more than one CD, the CCRS setting operation is performed after every disc change. In this case, the deck stops automatically and restart recording after having completed the CCRS operation. O p . NotesNotes 1. When the CCRS key is pressed during playback of CD, the playback stops and the CCRS setting (preparation for edited recording) starts. 2. Edit recording is not possible with CDs containing a track that is longer than one tape side, which may occur with classical music, etc. 3. If the deck is set for one-side recording (O), the processing at the tape end is applied only on side A. 55Convenient CD recording 55Convenient CD recording XD SERIES (En/E2) Giving preference to the tape length over the title sequence (Time edit recording) When the tape recording time is specified, recording is executed with changing the title sequence so that no title will be interrupted when the tape direction is changed at the end of one side. For C-H6: Character information indicators cannot be dis- When equalizer, SRS 3D or another effect is applied NoteNote played while the spectrum analyzer display is used. Switch to the sound, the sound with the applied effect can to the dual display or character display mode to see the be recorded. OP information. !« Recording preparations are required. ¤ UUUUU For the reverse mode, select “O” ,“[”(two-way recording). 1 1 Press so that the “PGM” indicator goes off. Should be OFF. P.MODE PGM 2 2 Light the “EDIT” indicator. Lights EDIT PGM EDIT If more than 8 seconds have elapsed, OWhen pressing the EDIT key, “SPACE” indicator also lights up with select the mode again. “EDIT” indicator. To cancel the auto-space function, press the SPACE key. aq 3 3 Enter the disc and tape conditions. PTY SEARCH 1 2 3 4 5 6 7 8 9 0 +10 1Enter the disc No. (DP-MH5 only) 2Press the EDIT key. (DP-MH5 only) DISC SKIP Go to step 2 within 8 seconds. Go to step 3 within 8 seconds. 3Enter the recording length of the tape. For the systems including DP-H5 : PGM EDIT C--D1 For the systems including DP-MH5 PGM EDIT CD C---; OThe recording time is 99 minutes maximum. OUp to 32 tracks can be edited. OCD tracks will be edited automatically onto tape sides A and B. After editing, the “EDIT” indicator stops blinking and starts to light steadily. Press the numeric keys as shown below. 30-minute tape : 000) 46-minute tape : 00006 46-, 54-, 60- or 90-minute tapes can be selected simply by pressing the TIME key for the required number of times. (The recording time can be adjusted in 1-minute steps with the 4 and . keys.) After entry, press the EDIT key then proceed to step 4. Application 4 4 Start edit recording. During recording: X-H5 Blinks Lights O p . CCRS Blinks Wait until the “EDIT” indicator stops blinking, and then press the CCRS key. CCRS REC / ARM OThe tape and CD stop automatically when recording has completed. NoteNote Depending on the combination of conditions from CD contents (number of titles and length of the titles) and tape recording time, interruption of a title may not be avoidable. In such a case, the respective title will not be recorded. 56 Convenient CD recording 56 Convenient CD recording XD SERIES (En/E2) NoteNote For C-H6: Character information indicators cannot be displayed while the spectrum analyzer display is used. Switch to the dual display or character display mode to see the information. !« To check the edited contents (Program edit recording, Time edit recording) CHECK To clear the edited contents (Program edit recording, Time edit recording) Application sectionCLEAR P.MODE 0 01 02 03 04 05 06 OPEN / CLOSE Method: 1 Method: 2 For the systems including DP-H5 For the systems including DP-MH5 or DP-MH5 DP-H5 Example of checking the edited contents for program edit recording For the systems including the DP-H5 Program No. PGM CD )3 P-): 1 Track No.Blinks For the systems including the DP-MH5 Track No. PGM D2 )3 P-): 1 Disc No. Program No.Blinks OProgram edit recording : Each time the key is pressed, the program No. (P-NO) and the disc No. are displayed. OTime edit recording : Edit indicator blinks, and edited contents are shown in order with the music calender indicators. OWhen the P.MODE key is pressed at the time of program recording, all editing contents are erased. When the CLEAR key is pressed, the tracks are d...

Questo manuale è adatto anche per i modelli :
Stereo - XD-6051 (2.13 mb)
Stereo - XD-6551 (2.13 mb)
Stereo - XD-8001 (2.13 mb)
Stereo - XD-8051 (2.13 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie