|
Facilità d'uso
DEL GAL. @ 100° F RISE RECOVERY GPH @ DEGREE RISE 40° F 100° F 140° F 80PDVILN-150 150,000 BTUH 201 364 145 104 80PDVILN-200 180,000 BTUH 250 436 175 125 80PDVILN-250 220,000 BTUH 298 533 213 152 100PDVILN-150 150,000 BTUH 215 364 145 104 100PDVILN-200 180,000 BTUH 245 436 175 125 100PDVILN-250 220,000 BTUH 283 533 213 152 a Propane Gas Inputs (LP) 1ST HR. DEL GAL. RECOVERY GPH @ @ 100° F DEGREE RISE RISE 40° F 100° F 140° F 80PDVI-250-XA 225,000 BTUH 274 545 218 156 100PDVI-250-XA 225,000 BTUH 288 545 218 156 MODEL NUMBER STORAGE (GAL) RATED INPUT (BTU/HR) 1ST HR DEL GAL @100°F RISE RECOVERY GPH @ DEGREE RISE DIMENSIONS (INCHES) SHIPPING WEIGHT A HEIGHT B DIA. C TOP WATER CONN. D F&R HOT CONN. E F&R COLD CONN. F GAS CONN. G TOP VENT HEIGHT WATER CONN. GAS CONN. DIA. RELIEF VALVE OPEN. STD (LBS) ASME (LBS) 40° F 100° F 140° F 80PDVI-150 80 150,000 204 364 145 104 63-1/2 28-1/4 65-1/8 51-5/16 20-3/16 17-1/4 68-3/16 1-1/12(T&F) 2(R) 3/4 3/4 645 N/A 80PDVI-200 80 199,999 253 485 194 139 63-1/2 28-1/4 65-1/8 51-5/16 20-3/16 17-1/4 68-3/16 1-1/12(T&F) 2(R) 3/4 3/4 645 N/A 80PDVI-250 83 250,000 301 606 242 173 63-1/2 28-1/4 65-1/8 51-5/16 20-3/16 17-1/4 73-1/16 1-1/12(T&F) 2(R) 3/4 1 645 720 100PDVI-150 100 150,000 219 364 145 104 74-1/8 28-1/4 74-1/8 60-5/16 20-11/16 17-1/4 77-3/16 1-1/12(T&F) 2(R) 3/4 3/4 735 N/A 100PDVI-200 100 199,999 266 485 194 139 74-1/8 28-1/4 74-1/8 60-5/16 20-11/16 17-1/4 77-3/16 1-1/12(T&F) 2(R) 3/4 3/4 735 N/A 100-PDVI-250 100 250,000 312 606 242 173 74-1/8 28-1/4 74-1/8 60-5/16 20-11/16 17-1/4 82-1/16 1-1/12(T&F) 2(R) 3/4 1 735 815 Natural Gas use the suffix "NA", Example: 80PDVI-150-NA LP on 80PDVI-250 and 100PDVI-250 only. Use suffix "XA" to order. Example: 80PDVI-150-XA ASME Construction available on the 80PDVI-250 and 100PDVI-250 only; Use suffix "A" to order; Example: 80PDVI-250-NA-A For Low NOx compliance to meet SCAQMD requirements, place an "LN" in the model number; Example: 80PDVILN-250-NA T=Top, F=Front, R=Rear These models meet or exceed the Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b current standard. 115V A.C. Required T&P Valve, Brass Drain Valve, Dielectric Fittings, Magnesium Anode Rods: Factory Installed Pressures (all): Working Pressure, 150 psi; Tested Pressure, 300 psi Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.1. Caution: The recommended ...
Questo manuale è adatto anche per i modelli :scaldabagno - 80PDVI-250-XA 225 (339.37 kb)
scaldabagno - Energy Saver 100PDVI-250 (339.37 kb)
scaldabagno - Energy Saver 80PDVI-150-NA (339.37 kb)
scaldabagno - Energy Saver 80PDVI-250-NA-A (339.37 kb)