Pressure) Propane/LP From External Regulator (11" W.C.** to 14" W.C. Pressure) Sediment Trap Figure 3 - Gas Connection * Purchase the optional CSA design-certified equipment shutoff valve from your dealer. ** Minimum inlet pressure for purpose of input adjustment. CHECKING GAS CONNECTIONS PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect log set and its individual equipment shutoff valve from gas supply piping system. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect log set and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 4). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 3. Check all joints from gas meter for natural gas (see Figure 5, page 5) or propane/LP supply (see Figure 6, page 5) to equipment shutoff valve. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 4. Correct all leaks at once. Equipment Shutoff Valve Open Closed Figure 4 - Equipment Shutoff Valve WARNING:Testallgaspiping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. CAUTION: If using propane/ LP gas, make sure external regulator has been installed betweenpropane/LPsupplyand appliance. 901053-01J 901053-01J 5 Figure 6 - Checking Gas Joints (Propane/ LP Gas Only) Figure 5 - Checking Gas Joints Gas Meter Equipment Shutoff Valve installation Continued Equipment Shutoff Valve Propane/LP Supply Tank 6. Install the inlet fitting into the inlet opening of the gas control valve (see Figure 9). Use thread sealant on the male pipe threads. 7. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward. ILOT Figure 8 - Gas Control Valve with Thermocouple and Pilot (Valve May Vary from Illustration) Thermopile and Line Pilot and Line Gas Control Valve Pressure Tap - Out (Manifold) Pressure Tap - In (Inlet) GA9150A Remote Rea dy Valve / Pilot Kit Assembly Natural Gas Installation 1. Remove burner inlet fitting from burner manifold (see Figure 7). 2. Use 10 mm socket to remove the orifice (see Figure 11, page 6). Replace with the proper orifice for your log set. See technical information charts in Figure 1 on page 2. 3. Thread the gas control valve onto the burner inlet fitting (see Figure 7). Use thread sealant on the male threads of the burner inlet fitting. Hold the burner inlet fitting with a wrench to prevent overtightening the connection to the burner. Make sure the control knob is facing the front (see Figure 7). 4. Replace burner inlet fitting into burner manifold (see Figure 7). 5. Attach the pilot gas line to the pilot outlet of the gas control valve and tighten. Connect thermocouple wires to TP and TPTH terminals on gas valve terminal block. See Figure 8. Do not overtighten. If using propane/LP gas, see Changing Pilot Orifice, page 7. Burner Inlet Fitting (containing orifice) Gas Control Valve Burner Pan Assembly Figure 7 - Installing Gas Control Valve (Valve May Vary from Illustration) Control Knob Figure 9 - Installing Inlet Fitting and Gas Connector Tube (Valve May Vary from Illustration) Gas Control Valve Gas Inlet Fitting Gas Connector Tube Inlet Opening INSTALLATION Continued 8. Thread the gas supply adaptor to the fireplace gas supply pipe. Adjust to most convenient position. 9. Install the gas connector tube to the gas supply adapter. Carefully shape tube and attach to gas inlet fitting (see Figure 9, page 5). Be careful not to cause kinks in tube. 10. Test for leaks following instructions in your hearth kit owner’s manual under the section Testing Burner for Leaks. 11. Retighten and adjust the location of the gas control as necessary. The gas control should be level, with the control knob to the front. 12. Install cover to burner pan using screws provided. 13. Install thermocouple, pilot, and piezo ignitor cover onto valve cover as shown in Figure 10. Use the provided screws. Piezo Ignitor Screw Valve Cover Figure 10 - Installing Thermocouple, Pilot, and Piezo Ignitor Cover (Valve May Vary from Illustration) Thermopile Ignitor Pilot Piezo Ignitor Cover Machine Scr...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie