Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Wayne-Dalton, Modello THERMOMARK 5200

Produttore : Wayne-Dalton
File Size : 5.84 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


1/2.- 5/8. 4. 1. OVERLAP 1. 1/2.- 5/8. 4. 1. 1/2.- 5/8. 4. FLUSH 1. 4. 4 3/4. 5/16 X 1. DRILLING / TAPPING SCREW 3/8 X 3. MIN. SLEEVE ANCHOR OPTIONAL MOUNTING BRACKET 5. OPTIONAL MOUNTING BRACKET 3/8 X 3. MIN. SLEEVE ANCHOR 5/16 X 1. DRILLING / TAPPING SCREW 2. X 6. JAMB IS RECOMENDED 1/2.- 5/8. 2 1/2. MIN. SIDE ROOM 1. OVERLAP 1 1/2. 1/2.- 5/8. 3 1/2. 1. OVERLAP 1 1/2. 1/2.- 5/8. 3 1/2. 1. OVERLAP 1 1/2. 1/2.- 5/8. 3 1/2. FLUSH 1 1/2. 3 1/2. 4 3/4. 5/16 X 1. DRILLING / TAPPING SCREW 3/8 X 3. MIN. SLEEVE ANCHOR OPTIONAL MOUNTING BRACKET 4 3/4. OPTIONAL MOUNTING BRACKET 3/8 X 3. MIN. SLEEVE ANCHOR 5/16 X 1. DRILLING / TAPPING SCREW 2. X 6. JAMB IS RECOMENDED 1/2.- 5/8. 2 1/2. MIN. SIDE ROOM 2 1/2. MIN. SIDE ROOM 3 1/2. MIN. SIDE ROOM 5. MIN. SIDE ROOM 3. MIN. SIDE ROOM 3. MIN. SIDE ROOM 3. MIN. SIDE ROOM 5/16 X 1 5/8. LAG SCREW 5/16 X 1 5/8. LAG SCREW 1. OVERLAP (3) 1/4-20 X 7/8. SELF DRILLING TEK SCREWS (4) 1/4-20 X 5/8. SELF DRILLING TEK SCREWS OPERATOR BRACKET U-BAR Fig. AA U-BAR OPERATOR BRACKET (4) 1/4-20 X 5/8. SELF DRILLING TEK SCREWS (6) 1/4-20 X 7/8. SELF DRILLING TEK SCREWS Fig. BB 6. GIRT OPERATOR BRACKET (12) 1/4-20 X 7/8. SELF DRILLING TEK SCREWS Fig. CC (4) 1/4-20 X 7/8. SELF DRILLING TEK SCREWS THROUGH OPERATOR BRACKET INTO GIRT MODELS 5155 & 5255 PART NUMBER 293009 38in WIDE X 19 5/8 in HIGH FOR 24 in TOP SECTION PART NUMBER 293010 38in WIDE X 16 7/16 in HIGH FOR 21 in TOP SECTION ATTACH USING (12) PRE DRILLED HOLES MODELS 5150 & 5200 PART NUMBER 295687 50 in WIDE X 17 1/4 in HIGH FOR 24 in TOP SECTION PART NUMBER 295686 50 in WIDE X 14 in HIGH FOR 21 in TOP SECTION MOUNT BRACKET OVER HINGES IN CENTER OF SECTION, DRILL (2) 9/32. HOLES IN EACH CORNER AND SECURE USING (12) 14-20. X 7/8. SELF DRILLING TEK SCREWS (SEE NOTE BELOW) THIS RECTANGULAR DESIGN IS FOR DOORS OVER 20 ft. 2 in. WIDE. NOTE: MODEL 5150 & 5200 DOORS BETWEEN 20 ft 2 in AND 24 ft 2 in REQUIRE THAT THE OPERATOR BE MOUNTED OFF CENTER SO THE OPERATOR BRACKET MOUNTS TO THE HINGE POINTS. STEP 13: Operator Trolley Bracket Installation: Attach the operator trolley bracket as illustrated in Fig. AA. This trolley bracket is limited to doors 14.2. X 10. (5 Sections high and smaller). For doors 14.2. X over 10. (5 sections) and 14.3. thru 20.2. by all heights see Fig. BB. For doors over 20.2. by all heights see Fig. CC. MODELS 5150, 5155, 5200, & 5255 PART NUMBER 295689 THIS DESIGN IS FOR DOORS UP TO 14. 2. WIDE AND OVER 10. (5 SECTIONS HIGH) AND 14.3. THRU 20.2. BY ALL HEIGHTS NOTE: TROLLEY BRACKET TO BE INSTALLED OFFSET FOR ODD PANELS MODELS 5150, 5155, 5200, &5255 PART NUMBER 107319 DOORS UP TO 14 ft 2 in WIDE X 10. (5 SECTIONS HIGH) NOTE: TROLLEY BRACKET TO BE INSTALLED OFFSET FOR ODD PANELS PG. 3 Intermediate hangers for all doors over 11. high and over 14. wide. Positioned half way between jamb and rear hanger. Lateral brace all hanger angles. Use a 3/8. X 3/4. truss bolt for roller clearence. 3/8. dia. Bolt should protrude into track to serve as a roller stop. Apply locking pliers to secure while attaching hangers. Use 12 ga. minimum angle (1-5/8. X 2-3/8.) 3/4. Doors 16. to 18. use 2 intermediate hangers. Over 18. use hangers at 6. max. centers NOTE: Use a chalk line or line level to ensure all bearing brackets are in line. (± 1/8.) PG. 13 1/4. GRADUATION 8 SECTIONS HIGH OR LESS FIG.A 5. to 8. 18. o.c. NOTE: For doors over 8 sections high and using 3 in. track, start with (2) # 3 hinges, (2) #4 hinges, (2) # 5 hinges, etc... #3 HINGE (3in. Track) #3 HINGE (3in. Track) #4 HINGE (3in. Track) #4 HINGE (3in. Track) #5 HINGE (3in. Track) 1/8. GRADUATION OVER 8 SECTIONS HIGH Refer to Fig R Page 12. #5 HINGE (2in. Track) #7 HINGE (3in. Track) #4 HINGE (2in. Track) #6 HINGE (3in. Track) #3 HINGE (2in. Track) #5 HINGE (3in. Track) #2 HINGE (2in. Track) #4 HINGE (3in. Track) #1 HINGE (2in. Track) #3 HINGE (3in. Track) FIG.B FIG. G FIG.C Secure Bracket using (5) screws. (No Spacer) FIG.D FIG.E Secure Bracket using (5) screws. FIG. F FIG.H Single Wide 2. & 3. secure using 5 screws Double Wide 2. & 3. secure using 10 screws 2. use 3/16. spacer 3. use 3/16. spacer 5200 & 5255 Single Wide 2. & 3. secure using 5 screws 2. use 3/16. spacer 3. use 1/2. spacer 5150 & 5155 Single Wide 2. secure using 5 screws Single Wide 2. secure using 5 screws STEP 3. Locate the bottom section, attach bottom seal using 1/4. self drilling and tapping screws as shown in Fig. A . Locate the left and right hand bottom brackets, secure the counterbalance cable using clevis pin, washer and cotter key shown in Fig. C Locate the left and right hand bottom brackets, secure the counterbalance cable over the large milford pin shown in Fig. D Secure bottom bracket to section using 1/4. drilling and tapping screws shown in Fig. E (for doors over 18.2. wide use doublewide bottom brackets as shown in Fig. H) (For doors using Broken Cable Safety Device Refer to Fig. B and page 12 Fig. R.) Align the appropriate end hinge to the pre-punched holes in the endstile and secure using (2) ...

Questo manuale è adatto anche per i modelli :
Cancello automatico - THERMOMARK 5150 (5.84 mb)
Cancello automatico - THERMOMARK 5255 (5.84 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie