Produttore : Chamberlain
File Size : 5.05 mb
File Nome : 114a2739.pdf
|
Facilità d'uso
Pliers Wire Cutters Claw Hammer Hack Saw Screwdriver Adjustable End Wrench Sockets and Wrench Drill Tape Measure 21 Stepladder Pencil 4 mm, 5 mm and 8 mm Drill Bits Carpenter's Level (Optional) 3 Safety Reversing Sensor Support bracket & fastening hardware is required. See page 21. — — — — — — — — Header Wall FINISHED CEILING Torsion Spring Extension OR Spring Safety Reversing Sensor Gap between floor and bottom of door must not exceed 6 mm. Access Door Wallmounted Door Control Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.). See page 25 for details. Motor unit Slack in chain tension is normal when garage door is closed (Optional Accessory) (Optional Accessory) Vertical Centerline of Garage Door 4 SECTIONAL DOOR INSTALLATION Planning Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener. Depending on your requirements, there are several installation steps which may call for materials or hardware not included in the carton. • Installation Step 1 – Look at the wall or ceiling above the garage door. The header bracket must be securely fastened to structural supports. • Installation Step 5 – Do you have a finished ceiling in your garage? If so, a support bracket and additional fastening hardware may be required. • Do you have an access door in addition to the garage door? If not, Model 1702E Outside Quick Release is required. See Accessories page. • Look at the garage door where it meets the floor. Any gap between the floor and the bottom of the door must not exceed 6 mm. Otherwise, the safety reversal system may not work properly. See Adjustment Step 3. Floor or door should be repaired. SECTIONAL DOOR INSTALLATIONS • Do you have a steel, aluminum, fiberglass or glass panel door? If so, horizontal and vertical reinforcement is required (Installation Step 10). • The opener should be installed above the center of the door. If there is a torsion spring or center bearing plate in the way of the header bracket, it may be installed within 1.2 m to the left or right of the door center. See Installation Steps 1 and 10. Chain Pulley Bracket Header Bracket Trolley Straight Door Arm Emergency Release Rope & Handle Door Bracket Garage Door Curved Door Arm Garage Door Spring Header Wall CLOSED POSITION 5 Planning (Continued) ONE-PIECE DOOR INSTALLATIONS • Generally, a one-piece door does not require reinforcement. If your door is lightweight, refer to the information relating to sectional doors in Installation Step 10. • Depending on your door’s construction, you may need additional mounting hardware for the door bracket (Step 10). Without a properly working safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • The gap between the bottom of the garage door and the floor MUST NOT exceed 6 mm. Otherwise, the safety reversal system may not work properly. • The floor or the garage door MUST be repaired to eliminate the gap. WARNING CAUTION Safety Reversing Sensor (Optional Accessory) FINISHED CEILING Support bracket & fastening hardware is required. See page 21. Slack in Chain Tension is Normal When Garage Door is Closed Safety Reversing Sensor (Optional Accessory) Header Wall Access Door Gap between floor and bottom of door must not exceed 6 mm. Motor Unit Wall-mounted Door Control ONE-PIECE DOOR WITHOUT TRACK CLOSED POSITION Access Door Gap between floor and bottom of door Safety Reversing must not exceed 6 mm Sensor (Optional Accessory) Wall- Mounted Door Control Cable Pulley Bracket Door Bracket Straight Door Arm Trolley Header Wall Rail Garage Door Emergency Release Rope & Handle Chain Header Bracket Curved Door Arm Safety Reversing Sensor (Optional Accessory) ONE-PIECE DOOR WITH TRACK Chain Pulley Bracket Header Bracket Trolley Straight Door Arm Manual Release Rope & Handle Door Bracket Garage Door Curved Door Arm Garage Door Spring Header Wall Chain CLOSED POSITION 6 Safety Reversing Sensor (Optional Accessory) Safety Reversing Sensor (Optional Accessory) Header Wall Safety Reversing Sensor (Optional Accessory) Safety Reversing Sensor (Optional Accessory) SLIDING GATE INSTALLATION SWINGING GATE INSTALLATION Planning (Continued) GATE INSTALLATIONS • It is recommended that you attach fine mesh or screening across the inside of swinging or sliding gates in order to prevent intruders from reaching through the bars and releasing the trolley from the door arm or pressing the door control button. • The opener must be protected from rain and/or moisture. Without a properly working safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing gate. • Activate gate ...
Questo manuale è adatto anche per i modelli :Cancello automatico - 1225E FS2 (5.05 mb)