Facilità d'uso


Do not restart the inverter until the source of the problem has been identified and corrected. • To avoid battery drain, always disconnect the inverter when not in use. • Do not expose the inverter to moisture. • Avoid placing the inverter near sources of heat or in direct sunlight. • When in use, make certain that the inverter is properly ventilated. • Do not use the inverter near flammable materials, fumes or gases. • Always operate the inverter in accordance with the instructions in this manual. Failure to do so may result in property damage, personal injury or loss of life. 19 TROUBLESHOOTING TROUBLESHOOTING pro200-4/30/2010 9:07 AM Page 23 TROUBLESHOOTING TROUBLESHOOTING pro200-4/30/2010 9:07 AM Page 23 PROBLEM: Low Battery Alarm On All The Time Please visit our Inverter FAQ page on our website (whistlergroup.com), for more troubleshooting information and FYI topics. PROBLEM: TV Interference Problem Solution Input voltage below Keep input voltage above 10.5 volts. 10.5 volts to maintain regulation. Poor or weak battery Replace battery. condition. Inadequate power being Use lower gauge wire. delivered to the inverter (400 watt model) or excessive voltage drop. Problem Electrical interference from inverter. . Solution Add a Ferrite data line filter on to the TV power cord. This filter is available at electronic part stores. Red LED On Problem Solution Equipment has a high start up surge. Turn inverter power switch OFF (O) and then ON (l) again until the inverter powers your appliance. Repeat as necessary to get your appliance "started". Battery voltage below Recharge or replace 10 volts. battery. Equipment being operated Use a higher capacity draws too much power. inverter. Inverter is too hot (thermal shutdown mode). Allow inverter to cool. Check for adequate ventilation. Reduce the load on the inverter to rated continuous power output. PROBLEM: Low or No Output Voltage Problem Solution Using incorrect type of Use a true RMS reading voltmeter to test output meter. voltage. See "For You Technical Types" Section of this manual. 20 21 SPECIFICATIONS TROUBLESHOOTING pro200-4/30/2010 9:07 AM Page 25 SPECIFICATIONS TROUBLESHOOTING pro200-4/30/2010 9:07 AM Page 25 PROBLEM: TV Does Not Work Pro-200W WATT INVERTER SPECIFICATIONS Problem Solution TV does not turn on. Try rocking the ON/OFF switch of the inverter while leaving the TV ON (see page 7). Contact TV manufacturer for start-up surge and/or to find out if TV is compatible with a modified sine wave. A larger inverter may be required. Maximum Continuous Power ..................... 200 Watts Maximum Surge Capability (Peak Power) 400 No Load Current Draw...................................... < 0.6 A Waveform .................................... Modified Sine Wave Operating Input Voltage Range. 11– 15.5+/-0.5 Volts AC Receptacle............ Two North American 3 Prong Fuses .................... (1) 25 Amp (Spade Type-Internal) USB.................................................. 5 Volt 500mA Max Approximate Dimensions 5.15" L x 3.86" W x 1.81" H Approximate Weight ...................................... .0.77 lbs Pro-400W WATT INVERTER SPECIFICATIONS Maximum Continuous Power ..................... 400 Watts Maximum Surge Capability (Peak Power) 800 Watts* No Load Current Draw...................................... < 0.7 A Waveform .................................... Modified Sine Wave Operating Input Voltage Range11 – 15.5+/-0.5 Volts AC Receptacle............ Two North American 3 Prong Fuses ...................... (2) 25 Amp (Spade Type-Internal) USB.................................................. 5 Volt 500mA Max Approximate Dimensions 5.15" L x 3.86" W x 1.81" H Approximate Weight ......................................... 1.0 lbs * Under certain conditions your inverter may provide up to 2 times the continuous rating for a brief period. 22 23 WARRANTY WARRANTY pro200-4/30/2010 9:07 AM Page 27 WARRANTY WARRANTY pro200-4/30/2010 9:07 AM Page 27 Consumer Warranty This Whistler is warranted to the original purchaser for a period of two years from the date of original purchase against all defects in materials This limited warranty is void if the unit is abused, installed improperly, had its housing removed, or has a missing serial number. There are no express warranties covering this product other than those set forth in this warranty. All express or implied warranties for this product are limited to two years. Whistler is not liable for damages arising from the use, misuse, or operation of this product. Service Under Warranty During the warranty period, defective units will be repaired or replaced (with the same or a comparable model), at Whistler’s option, without charge to the purchaser when returned with a dated store receipt to the address below. Units returned without a dated store receipt will be handled as described in section “Service Out Of Warranty.” When returning a unit for service, please follow these instructions: 1. Ship the unit in the orig...

Questo manuale è adatto anche per i modelli :
batterie per auto - PRO-200W (557.44 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie