Log:
valutazioni - 3, GPA: 3 ( )

Istruzioni per l'uso Kenwood, Modello KAC-PS541

Produttore : Kenwood
File Size : 763.02 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


"FAN" Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF". 3 Exit Menu mode Press the [MENU] button for at least 1 second. NOTE When the internal temperature is -22°F/-30°C or less, "-22F"/"-30C" is displayed. Separate Amp Control The following explains how to control the sound of amplifier B using the Amplifier Control of the unit. 1 Enter Menu mode Press the [MENU] button. 2 Select the Menu item Press the [MENU] button. The setup items are displayed approximately 1 second first, then the set values are displayed. 3 Adjust the Menu item Press the [2] or [3] button. The setup items and set values are switched as follows. Display Range Adjustment Item "VOLT"/"CURR"/"TEMP"/"FAN" For the operation method refer to 'Display mode' "BASS" 60/80/100/200 (Hz) Bass Center Frequency "BA G" B–15 — B+15 (dB) Bass level "BA Q" Q1.00/Q1.25/Q1.50/Q2.00 Bass Q Factor " EXT" ON/OFF When the bass extend is set to ON, low frequency response is extended by 20%. "TREB" 10/12/15/17 (kHz) Treble Center Frequency "TR G" T–15 — T+15 (dB) Treble level "VOL" –20 — 0 (dB) Volume offset "TEMP" FAHR (Fahrenheit) or CELS (Centigrade) The Fahrenheit or Centigrade temperature unit can be selected for the Display mode. "DEFA" For the operation method refer to 'Default' "AMP" 0 — 7 The ID Number you have assigned is displayed. 4 Exit Menu mode Press the [MENU] button for at least 1 second. NOTE When you hold down the [3] button 3 or more seconds during ID number display ("AMP"), message "MEMO" is displayed and you can register the values you have set with the Amplifier Control. To call the Amplifier Control’s values, hold down the [2] button 3 or more seconds during ID number display ("AMP"). Then, you can recall the value when message "LOAD" is displayed. Default Resets all values you have set to the initial (default) values. 1 Enter Menu mode Press the [MENU] button. 2 Select Default mode Press the [MENU] button. Select the "DEFA" display. 3 Resets the value to its default Press the [3] button for at least 2 seconds. Message "----" is displayed, and the value is initialized. 4 Exit Menu mode Press the [MENU] button for at least 1 second. NOTE Volume offset value can not be initialized. Display Demonstration The "VOLT"/"CURR"/"TEMP"/"FAN" items are displayed repeatedly. Press the [MENU] button for at least 2 seconds. The indicator flashes in the Demonstration mode. Canceling the Demonstration mode Press any button to cancel the Demonstration mode. Control an Amp from Center Unit The following explains how to control the sound of Amplifier B by operating the Amplifier Control of the unit from the Center Unit. 1 Enter AMP Control mode Select the AMP Control mode by following the 'AMP Control' procedure given on the Operation Manual of the Center Unit. NOTE Use the set item and value operation buttons by following the instructions given on the Operation Manual of the Center Unit. 2 Select an amp number to operate Operate the desired set item with the Center Unit. Select the "AMP NO"/"AMP CONTROL NO" display. NOTE When the Center Unit is in the STANDBY mode, message "AMP OFF" is displayed and you cannot operate the set items. 3 Set an ID number of Amp to operate Set an amp’s ID number on the Center Unit. You can select an ID number of "0" to "7" of connected amps. 4 Select the AMP Control item for adjustment Select the desired set item on the Center Unit. 5 Adjust the AMP Control item You can set a value of each item on the Center Unit. The set items and their values are switched and displayed as follows. Display Range Adjustment Item "VOLT"/"CURR"/"TEMP"/"FAN" The amp state is displayed. "VOLT" Indicates the source voltage (V). "CURR" Indicates the current consumption (A). "TEMP" Indicates the internal temperature (°F/°C). "FAN" Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF". "BAS F"/"BASS FREQ" 60/80/100/200 (Hz) Bass Center Frequency "BAS G"/"BASS GAIN" –15 — +15 (dB) Bass level "Q FA"/"Q FACTOR" Q1.00/Q1.25/Q1.50/Q2.00 Bass Q Factor "EXT"/"BASS EXT" ON/OFF When the bass extend is set to ON, low frequency response is extended by 20%. "TRE F"/"TREB FREQ" 10/12/15/17 (kHz) Treble Center Frequency "TRE G"/"TREB GAIN" –15 — +15 (dB) Treble level "VOL"/"VOL OFFSET" –20 — 0 (dB) Volume offset "AMP NO"/ "AMP CONTROL NO" 0 — 7 Select an ID number of the amp you use. 6 Exit AMP Control mode Releases the Amp Control mode by the Center Unit. NOTE When you have controlled the bass or treble of the sound using the Equalizer or DSP function of the Center Unit, and when you amplify the same frequency as that controlled by the Amplifier Control, the sound may be distorted due to an input overflow. Messages that may be displayed on the Center Unit When you are selecting an item with the Amp Control, an error status of the amplifier is displayed on the Center Unit. Display Informations "AMP . E-01"/"AMP . COND E-01" When the inside of the unit is overheating. "AMP . E-02"/"AMP . COND E-02" Wh...

Questo manuale è adatto anche per i modelli :
Avtousiliteli - KAC-X541 (763.02 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie