Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Jacuzzi, Modello J - 400 SERIES J - 470

Produttore : Jacuzzi
File Size : 10.43 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Massage Selector (4) • Massage selector 4 controls pump 1 output to footwell IX Jet. Jets Without Massage Selector Controls (5) • Jets 5 are always on when jets pump 2 is running. Page 29 -400 Series 10.14 J-480 Air Controls Diagram Air Controls Operation • Rotate air controls 1-4 to add air to designated jet groups. • Center footwell IX Jet draws air at all times when jets pump 1 is running. This jet has no air control. Page 30 J-400 Serie 10.15 J-470 Massage/Waterfall Selector Diagram Spa operation subject to change without notice. Massage Selectors (1-2) • Massage selector 1 diverts pump 2 output between jets groups 1a-1b. • Massage selector 2 diverts pump 1 output between jet groups 2a-2b. Waterfall Selector (3) • Waterfall selector 3 controls circulation pump output to waterfalls. Massage Selector (4) • Massage selector 4 controls pump 1 output to footwell IX Jet. Jets Without Massage Selector Controls (5) • Jets 5 are always on when jets pump 2 is running. Page 31 -400 Series 10.16 J-470 Air Controls Diagram Spa operation subject to change without notice. Air Controls Operation • Rotate air controls 1-4 to add air to designated jet groups. • Center footwell IX Jet draws air at all times when jets pump 1 is running. This jet has no air control. Page 32 J-400 Serie 10.17 J-465 Massage/Waterfall Selector Diagram Spa operation subject to change without notice. Massage Selectors (1) • Massage selector 1 diverts pump 1 output between jets groups 1a-1b. Massage Selector (2) • Massage selector 2 controls pump 1 output to footwell IX Jet. Waterfall Selector (3) • Waterfall selector 3 controls circulation pump output to waterfall. Jets Without Massage Selector Controls (4) • Jets 4 are always on when jets pump 2 is running. Page 33 -400 Series 10.18 J-465 Air Controls Diagram r@ @ tf a t fa üHi @ @ - _^ Ï>— W O H f L ---_ & Spa operation subject to change without notice. Air Controls Operation • Rotate air controls 1-3 to add air to designated jet groups. Page 34 J-400 Serie 10.19 J-460 Massage/Waterfall Selector Diagram J 'SÊÊÊÊÊKÊÊÊIIÊÊ Spa operation subject to change without notice. Massage Selector (1) • Massage selector 1 diverts pump 1 output between jets groups 1a-1b. Massage Selector (2) • Massage selector 2 controls pump 1 output to footwell IX Jet. Waterfall Selector (3) • Waterfall selector 3 controls circulation pump output to waterfall. Jets Without Massage Selector Controls (4) • Jets 4 are always on when jets pump 2 is running. Page 35 -400 Series 10.20 J-460 Air Controls Diagram Air Controls Operation • Rotate air controls 1-4 to add air to designated jet groups. • Center footwell IX Jet (5) draws air at all times when jets pump 1 is running. This jet has no air control. Page 36 J-400 Seriei 11.0 Heating Modes The control system in your spa activates a programmable “standard” or “economy” mode which effects when the heater operates. Refer to sections 11.1 and 11.2 below for additional information. 11.1 Standard Mode (Factory Default) Standard mode is typically selected by customers in cold climates where heat up times are extended due to lower ambient temperatures. In this mode, water temperature is regulated by the set temperature which activates the heater automatically as needed. 11.2 Economy Mode Economy mode is typically selected by customers in warm climates where heat up times are minimized due to higher ambient temperatures. In this mode, the water temperature is regulated by the set temperature only when a programmed filter cycle is running, unless in summer logic (page 39). 11.3 Selecting Standard or Economy Mode Press the MODE CD button to select either “Standard” or “Economy” mode. The control panel’s indicator on the right side of the LCD changes to indicate which mode is selected. 11.4 Clean-Up “Blow-Out” Cycle The clean-up cycle is once per day in both Standard and Economy modes at 12:00 (noon) for two minutes. This is not user programmable. Jets pump 2 activates for one minute to circulate any water in the plumbing. After 1 minute, jets pump 2 shuts off and jets pump 1 turns on, runs for 1 minute, then shuts off. Page 37 -400 Series J- 12.0 Programming Instructions 12.1 Programming Filter/Circulation Pump Run Time The Sentry control system allows you to easily adjust two separate aspects of filter/circulation pump operation: 1. The time of day (start time) the filter/circulation pump turns on. 2. The length of time (duration) the filter/circulation pump operates. The factory default start time is 12:00AM (Midnight). The default duration is 24 hours. To make adjustments, press the CYCLE © button to enter the filter/circulation pump programming mode. “Circ” appears on the LCD. Now, the system is ready to accept your changes: • Press the SELECT vS? button once. The previously /"A programmed start time appears on the LCD display. • Press WARMER or COOLER G) buttons to adjust the start...

Questo manuale è adatto anche per i modelli :
Piscine - J - 400 SERIES J - 460 (10.43 mb)
Piscine - J - 400 SERIES J - 465 (10.43 mb)
Piscine - J - 400 SERIES J - 480 (10.43 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie