Produttore : AquaPRO
File Size : 1.31 mb
File Nome :
|
Facilità d'uso
Note: It may take up to three days to reach the desired temperature during the opening of the swimming season. Without a pool blanket, it may take even longer and may not reach the desired temperature until later in the season. Weather Conditions Weather conditions play a big part in the operation of the heater. Low outside ambient temperature, high winds, low relative humidity, and a large amount of shading on the pool will all have an effect on how much time it takes to heat the pool and how much time it might need to maintain the desired temperature. Once the outside ambient temperature drops below 50.F, the heater may not operate. Troubleshooting Guide If the heater is not operating during the initial start-up, check to see if it has been installed properly, per this owner’s manual. Make sure the breaker has been sized properly. The following are conditions to check before calling Aqua Pro Systems for a service: Unit is not running: • Check the power light. Check to see if the breaker is set. • Make sure the filtration system is on • Make sure the thermostat is higher than the pool water temperature • Make sure the filter is clean and is allowing enough water to flow • Make sure the outside ambient temperature is higher than 50.F • Make sure the 5-minute time delay has passed • On the PRO100, make sure toggle switch is set to pool or spa mode and is not in the “OFF” position. Unit is running but not heating: • Check the air coming out of the top of the unit. It should be approximately 8.F - 15.F lower than the surrounding ambient air temperature. If not, call the factory for service. Unit runs continuously: • Check for correct wiring. • Lower the desired water temperature below the pool water temperature. If the unit is still running, call the factory for service. • If the unit shuts off when the thermostat is lowered, it may be running continuously because it cannot reach the desired temperature. A pool blanket may be required to help reach this temperature. Also, the filter pump may need to run longer for the heater to reach the desired temperature. Unit is cycling: • Check the filters for proper water flow. • Check the evaporator coil for severe frost. • Unit could be low on refrigerant. At this point, call the factory for service and turn off the power to the heater to keep the cycling from damaging the compressor. 1-877-AQUASYS 6 PRO400, PRO600, PRO1000 LIMITED WARRANTY For five (5) years from the date of purchase for the PRO400, PRO600 & PRO1000, Wayne Water Systems, d/b/a AquaPro Systems (“AquaPro”) will repair or replace, at its option, for the original owner any parts of its Heat Pumps (“Product”) which are found upon examination by AquaPro to be defective in materials or workmanship. For the Pro 1000 you are covered by a ten (10) year warranty on the compressor, which is prorated from years six (6) through ten (10). The PRO1000 also carries a lifetime warranty on the Titanium tubing in the heat exchanger. This Limited Warranty covers labor for a period of one (1) year on the PRO400 and PRO600 and a period of five (5) years in Florida and one (1) year outside of Florida on the PRO1000. Please call AquaPro at 1-877-AQUASYS (1-877-278-2797) for instructions. Be prepared to provide a receipt, the model number and serial number when exercising this limited warranty. Purchaser must pay all transportation charges on Products or parts submitted for repair or replacement. All non-warranty service charges are the responsibility of the original owner. Failure to pay for non-warranty service charges will void this Limited Warranty. This Limited Warranty does not cover Products that have been damaged as a result of accident, abuse, freezing, improper pool/spa chemistry on the PRO400 & PRO600, not the PRO1000 as illustrated and explained in the section Pool Chemistry and Warranty (pH not kept between 7.2 to 7.8; total alkalinity ppm not kept between 60 to 180; total Bromine ppm not kept between 2.0 to 10.0; free Chlorine not kept within proper minimum/maximum levels specified for pool or spa; Calcium hardness ppm as CaCO3 not kept within proper minimum/maximum levels specified for pool or spa; Cyanuric Acid not kept within proper minimum/maximum levels specified for pool or spa), misuse, neglect, improper installation, improper maintenance or failure to operate in accordance with AquaPro’s written instructions. All maintenance and service must be performed by service agents approved by AquaPro. Any unauthorized alteration or repairs will void this Limited Warranty. THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE (1) YEAR FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or ...
Questo manuale è adatto anche per i modelli :Piscine - PRO400 (1.31 mb)
Piscine - PRO1000 (1.31 mb)