2. Fill the pump strainer pot with water. 3. Reinstall the pump clamp and lid onto the strainer pot. The pump is now ready to prime. 4. Make sure all electrical connections are clean and tight. 5. Open the air release valve on the filter, and stand clear of the filter. 6. Switch the IntelliFlo pump on at the circuit breaker. Ensure that the green power light is on. 7. Press the Speed 1 button to select the pump speed of 750 RPM. 8. Press the Start button to start the pump. Use the Up/Down button to increase the speed as necessary to prime the pump. 9. When water comes out of the air release valve, close the valve. The system should now be circulating water back to the pool without air bubbles showing in either the hair and lint pot or at the pool return fittings. 10. Use the Up/Down button to adjust the operating speed as desired. Top view IntelliFlo 4 Installation and User’s Guide External Control with IntelliComm Communication Center The IntelliFlo 4 can be remotely controlled by the Pentair IntelliComm Communication Center using an optional communications cable (P/N 350122). The IntelliComm provides four pairs of input terminal connections. These inputs are actuated by either 15 - 240 VAC or 15 - 100 VDC. Using the device's inputs, the programmed IntelliFlo 4 pump speeds can be controlled. If more than one input is active the highest number will be communicated to the IntelliFlo pump. The IntelliComm will always communicate to pump address 1. The following table shows the wiring terminal descriptions for IntelliComm. External Control Terminals IntelliComm Communication Center Terminal number Terminal name Voltage Maximum current Phase type Frequency 1-2 Power supply 100 -240 VAC 100 mA 1 Input 50/60 Hz 3-4 Program 1 15 -240 VAC or 15 -100 VDC 1 mA* 1 Input 50/60 Hz 5-6 Program 2 15 -240 VAC or 15 -100 VDC 1 mA* 1 Input 50/60 Hz 7-8 Program 3 15 -240 VAC or 15 -100 VDC 1 mA* 1 Input 50/60 Hz 9-10 Program 4 15 -240 VAC or 15 -100 VDC 1 mA* 1 Input 50/60 Hz 11 12 RS-485 + Data: Yellow -Data: Green -5 to +5 VDC 5 mA 1 Output N/A Ground IntelliFlo 4 Installation and User’s Guide 10 IntelliFlo 4 Installation and User’s Guide Connecting IntelliFlo 4 to an EasyTouch System The IntelliFlo 4 can be controlled by an IntelliTouch system via the RS-485 communication cable (PN 350122). In this configuration, IntelliTouch starts, stops and controls the speed of the IntelliFlo pump. When the IntelliTouch does this, it rewrites the IntelliFlo 4 memory, which can take several seconds. This causes a delay from when a command is given on the IntelliTouch control panel until the Intelliflo 4 physically responds. The IntelliFlo 4 control panel is disabled when communicating with the IntelliTouch system. Note that IntelliTouch will not start communicating with the IntelliFlo 4 until the appropriate pump address is assigned to a circuit. The IntelliFlo 4 default pump address is one. See page 6 for details on how to change the address to 2, 3 or 4. For more information, refer to the IntelliTouch User's Guide (PN 520102). To connect the IntelliFlo cable to EasyTouch load center: 1. CAUTION - Switch the main power off to the EasyTouch Load Center. 2. Unlatch the two enclosure door spring latches, and open the door. 3. Remove the two retaining screws securing the high voltage cover panel, and remove it from the enclosure. 3. Loosen the two access screws securing the control panel. EasyTouch Load Center (front view) Control panel access screw Control panel access screw High voltage cover panel Retaining screw 11 IntelliFlo 4 Installation and User’s Guide 4. Lower down the hinged control panel to access the EasyTouch motherboard. 5. Route the communication cable into the lower plastic grommet, up through the low voltage raceway to the EasyTouch load center motherboard. 6. Strip back the cable conductors . inch. Insert the two wires into the screw terminals on the board. Secure the wires with the screws. 7. EasyTouch to IntelliFlo 4 pin configuration: • IntelliFlo: Connect pin 6 (green) to EasyTouch screw terminal pin 2 (green) • IntelliFlo: Connect pin 7 (yellow) to EasyTouch screw terminal pin 3 (yellow) 8. Insert the screw terminal onto the EasyTouch COM-PORT (J20) board connector. Note: Multiple wires may be inserted into a single screw terminal. Pin configuration EasyTouch (J20) screw terminal EasyTouch screw terminal connector IntelliFlo (2-wire cable) 2 (GRN) GREEN (Pin 6) 3 (YEL) YELLO (Pin 7) Pin 6 (Green) Pin 7 (Yellow) IntelliFlo connector pin configuration EasyTouch COM-PORT (J20) Indoor Control Panel IntelliChlor IntelliFlo RF Transceiver Low voltage Raceway Control panel motherboard 12 IntelliFlo 4 Installation and User’s Guide EasyTouch Load Center (front view) Control panel access screw Control panel access screw High voltage cover panel Retaining screw 9. Close the control panel into its original position and secure it with the two access screws. 10. Install the high voltage cover panel and secure it with the two reta...
Questo manuale è adatto anche per i modelli :Piscine - INTELLIFLO 100 (3.17 mb)