Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Raypak, Modello 402B

Produttore : Raypak
File Size : 211.31 kb
File Nome :

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Job:_ Hi Delta® - Type P Engineer:--Commercial Pool Heaters Contractor:--Models 302B & 402B Prepared By:_ Date:_ Model:_ Indoor/Outdoor:_ MBTUH Input:_ Sealed Combustion Chamber 100% Factory Fire Tested Efficiency: 85% Minimum Non-condensing Inlet Temperature: 105°F Thermal Shock Proof Heat Exchanger Limited Twenty-year Thermal Shock Warranty Limited Five-year Heat Exchanger Warranty Diagnostic Center with Fault History PolyTuf Powder Coated Cabinet No Combustible Floor Shield Required Fan-assisted Non-ferrous Bypass Patented Burner Security Blanket Heat Exchanger Bronze Headers ASME Inspected and Stamped 160 PSIG Working Pressure National Board Approved Cupro Nickel Finned Tubing ASME Steel Tube Sheet Silicone High Temp O-Rings 125 PSIG ASME Pressure Relief Valve Temperature and Pressure Gauge Water Connections □ Left - Standard □ Right - Option A-6 ■ Bronze Pump, 1/3 HP, 120V, 60Hz ■ Non-Ferrous Pool Bypass Assembly with Automatic Control Controls 120V, 60Hz, 10 Power Supply 120/24V 60Hz Transformer 100% Shut-off/Lockout Hot Surface Ignition Remote Flame Sensor High Limit Control, Auto Reset On/Off Power Switch Manual Shut-off, Front-mounted Flow Switch Blocked Vent Pressure Switch Combustion Air Proving Switch Economaster Pump Time Delay Poolstat Gas Train ■ Gas Pressure Regulator ■ Safety Shut-off Valve ■ Firing Control Valve ■ On/Off Firing ■ Fuel □ Natural Gas □ Propane Gas ■ Design Certified ANSI Z21.56/ CSA 4.7 Burner ■ Ultra-low NOx: Less Than 30 PPM Construction ■ Indoor/Outdoor Construction ■ Enclosed Front Controls Venting ■ Vent Location □ Top - Standard □ Rear - Option D-14 ■ Vent Termination Cap □ Outdoor - Option D-11 □ Indoor, Horizontal -Option D-15 □ Indoor, Vertical (by others) ■ Combustion Air □ In-Line Filter Kit (TruSeal only) - Option D-17 □ Air Intake Elbow -Option D-16 Options □ C-6 □ D-21 □ F-10 □ I-1 □ S-1 □ S-2 □ X-1 □ X-2 □_ Ignition Module, Manual Reset TruSeal™ Direct Vent Low Water Cut-Off, Remote Probe High Limit Control, Auto Reset Low Gas Pressure Switch, Manual High Gas Pressure Switch, Manual SureRack™ Kit SureRack Add-on Regulatory Agency Requirements □ G-1 CSD-1 A Rhasm'Company Catalog No.: 6000.312D Effective: 8-15-08 Replaces: 2-1-08 Hi Delta - Type P Models 302B & 402B Model FRONT VIEW BACK VIEW ...

Questo manuale è adatto anche per i modelli :
Piscine - 302B (211.31 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie