Log:
valutazioni - 3, GPA: 5 ( )

Istruzioni per l'uso Bogen, Modello TAMB2

Produttore : Bogen
File Size : 1.35 mb
File Nome : TAMB2m.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Other switches are at installer’s discretion. STATION ACCESS Set switches in black as indicated. Other switches are at installer’s discretion. 1 0 1 0 1 0 The contact closure contact set is provided to signal to external equipment the TAMB2.s operational state. The contact set is single pole, double throw, and changes state from what is screened below the terminals when the TAMB2 becomes active and returns when the unit becomes idle again. Contact Ratings: 0.6A @ 125V AC resistive 0.6A @ 110V DC resistive 2.0A @ 30V DC resistive 1 0 1 VOX ENABLE VOX DISCONF TNPRE ANN TNTRUNK MODE STATION LOOP START GND START DETECT CPC IGNORE 0 ON 1-RNG DLY NO TIMER TRNK TMER ANS IMMED RANGE (SEC) INHIBIT 11 100 - 200 01 50 - 100 01 1 - 50 00 < < < < O N 1 2 3 4 5 6 7 8 9 A B C C UNIT 1 UNIT 2 STEP 1 Side-By-Side Rack Mounting 1 2 Wall Mounting Wall Mount 1 - Insert mounting screws through mounting brackets and into the side/rear screw openings as shown. Once the brackets have been secured, the unit can now be affixed to a wall or other flat surface. Wall Mount 2 - The unit can also be secured to a wall or flat surface with the front face pointing upwards to provide less cantilever. Insert mounting screws through mounting brackets as shown. For installing two units into a single rack space, you will use the mounting brackets of both units to ultimately connect them into one combined unit. In STEP 1, start by attaching a mounting bracket onto the left/front side of Unit 1 as shown in figure A. Then attach a mounting bracket to the right/rear side of Unit 1, in a reverse manner, as shown in figure B. Then proceed to attach mounting brackets to both the left and right/front sides of Unit 2, as shown in figure C. In STEP 2, bring both Unit 1 and Unit 2 flush together. Attach the units by first inserting screws through the right/rear mounting bracket on Unit 1 and into the rear of Unit 2, as shown in figure D. Then insert screws through the left/front bracket on Unit 2 into the front of Unit 1, as shown in figure E. The side brackets can be mounted at the back end of the unit if a rear facing orientation is desired. D E UNIT 1 UNIT 2 STEP 2 Single Unit Rack Mounting For installing a unit into a single rack space, an RPK91 rack mounting kit is needed (sold separately). Insert mounting screws through the RPK91 mounting brackets and into the side/rear screw openings as shown. Once the brackets have been secured, the unit can now be attached to the rack. The side brackets can be mounted at the back end of the unit if a rear facing orientation is desired. Specifications Registration Number: Ringer Equivalence: Station Port Compatibility: Trunk Port Compatibility: Paging Frequency Response: Input/Output Impedance: Power Requirements: Pre-announce/Confirmation Tones: Default Disconnect Timer: VOX Disconnect Timer: Auxiliary Contact Rating: Operating Temperature Range: Connection Method: Finish: Dimensions: Shipping Weight: US: CD2PA13BTAMB2 1.3B Two-wire ring start Two-wire loop start or ground start 200 – 8000 Hz, ±1 dB 600 ohms, nominal 24V DC @ 150mA (user-supplied) 800 Hz, ±20%, one-half second duration 1 to 200 seconds, adjustable or inhibit 1 to 11 seconds, adjustable or inhibit 0.6A @ 125V AC resistive 0.6A @ 110V DC resistive 2.0A @ 30V DC resistive 32° – 120°F. Screw terminal Black enclosure with white lettering 8-1/2" W x 1-3/4" H x 3" D 2 lb. Limited Warranty; Exclusion of Certain Damages The Bogen TAMB2 Telephone Access Module is warranted to be free from defects in material and workmanship for two (2) years from the date of sale to the original purchaser. Any part of the product covered by this warranty that, with normal installation and use, becomes defective (as confirmed by Bogen upon inspection) during the applicable warranty period, will be repaired or replaced by Bogen, at Bogen’s option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA. Repaired or replacement product will be returned to you freight prepaid. This warranty does not extend to any of our products that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modified or repaired or altered in any manner whatsoever, or where the serial number or date code has been removed or defaced. THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen's liability arising out of the manufacture, sale or supplying of products or their use or disposition, whether based upon warranty, contract, tort or otherwise, shall be limited to the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDIN...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie