Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso Philips, Modello SCF274/30

Produttore : Philips
File Size : 507.88 kb
File Nome :
Lingua di insegnamento: enesfr
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


23. Do not use abrasive, anti-bacterial materials or scourers to clean the sterilizer. 24. Do not use softened water in the sterilizer. 25. A short power cord has been provided to prevent the risk of it becoming entangled or being tripped over. 26. Extension cords may be used if care is exercised in their use. 27. If an extension cord is used, its electrical rating must be as great as the rating of the appliance and not draped over the edge of the table top where it could be pulled by children or tripped over. The extension cord should be a grounded type 3 wire cord. 28. The power cord supplied must not be used on any other appliance and no other power cord should be used with the Sterilizer. 29. There are no serviceable parts inside the Sterilizer. Do not attempt to open, service or repair the Sterilizer yourself. 30. Failure to follow de-scaling instructions may cause irreparable damage. SAVE THESE INSTRUCTIONS 4 Instructions for Use Please refer to the diagrams in the back of the leaflet. Before using your sterilizer for the first time (see diagram B) Remove all items from inside the sterilizer body. 1) Pour in exactly 90 ml of tap water. 2) Assemble all the blue components (baskets, stem and bottle rack). Place the assembled components in the sterilizer and put the lid on. 3) Connect the cord into the back of the sterilizer and plug into an electrical outlet. The light should come on automatically. If it does not, press down on the sterilizer switch. 4) At the end of the cycle the unit will switch off automatically and the light will go out. 5) Allow unit to cool, unplug and disconnect the sterilizer cord from the back of the sterilizer. 6) Remove baskets and bottle rack, pour away any remaining water and wipe dry. Before each use 1) Before sterilizing, wash all items in mild soapy water and rinse. 2) Pour exactly 90 ml of water into the sterilizer body. If you add more than 90 ml you will prolong the cycle time. If you use less than 90 ml, your items may not be properly sterilized. Note: When loading, always ensure that the steam can effectively circulate around all surfaces and that any water can drain off easily. To sterilize up to six 4 oz/125 ml, 9 oz/260 ml or 11 oz/330 ml AVENT Bottles (see diagram C) 1) Slide the lower basket onto the central stem. 2) Thread 2 screw rings onto the central stem. 3) Slide the bottle rack down the central stem, with the neck facing down, until it rests on the top screw ring. 4) Place the nipples through the center of the holes in the bottle rack onto the lower basket. 5) Thread 4 screw rings onto the central stem. 6) Place the 6 inverted bottles in the bottle rack. 7) Push the upper basket onto the central stem until it rests on the catch. Place the 6 dome caps and tongs into the upper basket. 8) The upper basket is not required when sterilizing 11 oz/330 ml bottles (see diagram C8). 9) Place the assembled unit into the sterilizer body and put the lid on. 10) Put the cord into the back of the sterilizer body and plug into an electrical outlet. Switch on. 11) Cycle times will vary depending on the load. After each cycle the unit will switch off automatically and the light will go out (approx. cycle time: 8 minutes). To sterilize the Philips AVENT Manual Breast Pump (see diagram D) 1) Click the Breast Pump body into the slot in the upper basket and arrange the other breast pump components as shown. Assemble remaining components of the Breast Pump in the lower basket. 2) Up to six bottles (not including screw rings, nipples or dome caps) can be sterilized with the pump. 3) Place assembled unit into the sterilizer body, put the lid on. 4) Put the cord into the back of the sterilizer body and plug into electrical outlet. Switch on. To sterilize narrow neck bottles and other feeding items Nipples should be placed around the central stem in the lower basket and screw rings in the top basket, as they are too narrow for the stem. Always ensure items are positioned within baskets / racks to ensure effective circulation of steam. The bottle rack and / or upper basket can be removed to make more room. After sterilization (see diagram E) 1) Do not remove the lid right away. Let the sterilizer cool down for 3 minutes. 2) Unplug and disconnect the cord from the back of the sterilizer. 3) Wash your hands thoroughly before removing the sterilized items. 4) Remove the lid. 5) If necessary, shake excess water from items before assembling. 6) The tongs can be used to remove small items and to pull the sterile nipples through the screw rings of the bottles. 7) The contents will remain sterile for up to six hours, following the end of the cycle, provided the lid is not removed. 5 EN EN ES Esterilizador a Vapor Electrico Philips AVENT 8) Removed items must be used/assembled immediately or resterilized. Expressed milk can be stored in a breast milk container in the refrigerator for up to 48 hours (not in the door), the freezer for up to 3 months, or in a zero degree freezer for up to 6 mo...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie