Log:
valutazioni - 3, GPA: 4.7 ( )

Istruzioni per l'uso Huffy, Modello Universal Elevator Mount

Produttore : Huffy
File Size : 437.08 kb
File Nome : 0281a192-5826-2bc4-3166-e4a2dbf92cf4.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


5. Minimum distance should be 106” (2.7 m) from top elevator hole to playing surface. Homeowner must assume all responsiblilty for any personal or property damage if backboard height is lower then recommended. WARNING 106” (2.7 m) 3-1/2” (8.9 cm) 6 7 2 3 NOTE: Hardware for this procedure not included due to various roof construction materials and design structure. NOTE: Two people recommended for this procedure. Hold angled brackets (6 and 7) on roof and keep u-channel (2) upright. Measure from top of playing surface to upper elevator hole in u-channel. Distance should be 106” (2.7m). NOTE: To achieve 106” (2.7 m) you may have to make some adjustments. Such as turning the tube over on the opposite end, and/or moving angled brackets backward or adding height to the enitre assembly with wood between angled brackets and roof. Mark angled bracket locations on roof. Angled brackets (6 and 7) should be parallel to each other and 3-1/2” (8.9 cm) apart. 3. 4. Keep u-channel (2) upright and position struts (3) on desired location on roof approx. 26”-30” (66-76 cm) apart. Level tube in all directions. Mark and drill holes. Secure struts in place. 5. Minimum distance should be 106” (2.7 m) from top elevator hole to playing surface. Homeowner must assume all responsiblilty for any personal or property damage if backboard height is lower then recommended. WARNING 106” (2.7 m) 3-1/2” (8.9 cm) 6 7 2 3 3 4 P/N 211125A 10/01 11 IMPORTANT! Test fit bolts into holes of brackets (8) and carefully rock them in a circular motion to ream out paint from holes if necessary. IMPORTANT! Finger tighten nuts and bolts until instructed to fully tighten later. Fit spacer (11) into pawl (13) and fit pin of pawl through end slot of release lever (12). 10 15 13 166. 7. 8. 14 129 8 11 IMPORTANT! Test fit bolts into holes of brackets (8) and carefully rock them in a circular motion to ream out paint from holes if necessary. IMPORTANT! Finger tighten nuts and bolts until instructed to fully tighten later. Fit spacer (11) into pawl (13) and fit pin of pawl through end slot of release lever (12). 10 15 13 166. 7. 8. 14 129 8 IMPORTANT! Bolt (18) must be inserted through tube (17), spacer (19), support bracket (10), board bracket (8), release lever (12), wave washer (20), and then ratchet (21). Fully tighten all nuts and bolts after assembly. Use pliers to stretch spring (23) into position. 9. 10. 19 21 17 22 19 20 10 12 10. 8 18 23 17 5 10/01 P/N 211125A 6 P/N 211125A 10/01 Assemble elevator tubes (17) to backboard bracket (8). 22 19 18 17 Backboard and Rim NOT Included 8 17 13. Starting with nuts flush against bracket (8), secure rim and bracket to backboard. NOTE: Mounting nuts and bolts not included. Bend bracket (8) to line up with holes in backboard and secure. 11. 12. 8 19 NOTE: Do not use washers here on spring return style rim. 14. 14. 3 17 18 22 2 15. dowel 3/4”-7/8” diameter (19-22 mm) into the release lever. HEIGHT ADJUSTMENT Push up and move away from tube to raise and lower IMPORTANT! Push up, move toward tube and lower to lock. Release Lever Broom Handle or Wooden Dowel (not included) FOR POLE MOUNTING ONLY 1. Assemble mounting brackets (24) to 3-1/2” (8.9 cm) pole as shown. Position bracket assembly to approx. 106” (2.7 m) above level playing surface. Tighten nuts (28) completely. NOTE: Equal rotations of nuts on each side of u-bolt (25) are necessary. 26 25 24 106” (2.7 m) 27 28 ; PLAYING SURFACE 2. NOTE: Two people required for this procedure, elevator assembly is heavy. Mount assembled elevator 22 components to mounting bracket (24) as shown. (Refer to Steps 6 through 13 for elevator assembly.) 24 17 18 8 P/N 211125A 10/01 FLAT SURFACE MOUNTING FLAT SURFACE MOUNTING 1. A solid mounting base and/or surface, capable of withstanding normal recreational use forces, must be provided by the customer. A reliable carpenter or building contractor should be consulted if there are questions regarding this procedure. WARNING MOUNTING HOLE PATTERN 2. Secure mounting brackets (24) to flat solid surface. Install bolt heads outside for safety reasons. NOTE: Hardware for this procedure not included due to various roof construction materials and design structure. Mark bracket positions on flat solid surface. Upper bracket mounting holes should be located approx. 106” (2.7 m) above playing surface. Drill four, 3/8” (9.5 mm) holes into solid structure for mounting brackets (24). PLAYING SURFACE 106” (2.7 m) 24 248” (20.3 cm) 4” (10.16 cm) 9 10/01 P/N 211125A 3. NOTE: Two people required for this procedure, elevator assembly is heavy. Mount assembled elevator components to mounting brackets (24) as shown. (Refer to Steps 6 through 13 for elevator assembly.) 22 18 10 ft. (3.05 m) REGULATION RIM HEIGHT IS 10 FEET (3.05 m). 24 3. NOTE: Two people required for this procedure, elevator assembly is heavy. Mount assembled elevator components to mounting brackets (24) as shown. (Refer to Steps 6 through 13 for elevator assembly.) 22 18 10 ft. (3.05 m) REGU...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie