Log:
valutazioni - 4, GPA: 3.5 ( )

Istruzioni per l'uso B&B Electronics, Modello ESR904

Produttore : B&B Electronics
File Size : 1.22 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Set the Run/Console DIP switch on the Serial Server to the Run position LAN Ethernet cable Ethernet cable RS-232 cable ESR902 PC Serial Device Figure 19. Ethernet Connection via a LAN Manual Documentation Number: ESR90x-0508m Chapter 4 B&B Electronics Mfg Co Inc – 707 Dayton Rd -Ottawa IL 61350 -Ph 815-433-5100 -Fax 815-433-5104 – B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – Using ESP Manager Ethernet crossover cable RS-232 cable ESR902 PC Serial Device Figure 20. Direct Ethernet Connection using a Crossover Cable N NNo oot tte ee: :: Use an Ethernet Crossover Cable if connecting directly to a computer LAN card. Step 2: Apply power. The red Power indicator will light, the Link indicator lights when an Ethernet connection is made, and the Ready indicator will flash. Software Setup Step 3. To run the ESP Manager, from the Windows Desktop click: Start > Programs > B&B Electronics > VLINX > ESR Servers > VLINX ESP Manager As soon as the ESP Manager opens it will initiate Searching Server and after a few seconds the Serial Server List will display all (ESP90x and ESR90x) Serial Servers on the network. 24 Chapter 4 Manual Documentation Number ESR90x-0508m B&B Electronics Mfg Co Inc – 707 Dayton Rd -Ottawa IL 61350 -Ph 815-433-5100 -Fax 815-433-5104 – B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – Using ESP Manager Figure 21. The VLINX ESP Manager Window Software Overview The VLINX ESP Manager window provides the following information: • Menus (Server, View, Exit, Help) • Server Icons (Firmware Upgrade, Virtual COM Configuration, Searching Server, Uninstall Virtual COM, Monitor Port Status) • Serial Server / Virtual COM Lists • Software Status (Ready, Updating, Searching, etc) Menus Server • Firmware Upgrade - Used when downloading new firmware to the Serial Server. N NNo oot tte ee: :: See Chapter 8 for more information on upgrading firmware. • Virtual COM Configuration - Selects the Virtual COM List. Double clicking on any COM port in the Virtual COM List brings up a window that allows changing the virtual COM settings such as Flow Control, Protocol, IP address, and Port Number. Virtual COM settings must match Serial Server port settings. Manual Documentation Number: ESR90x-0508m Chapter 4 B&B Electronics Mfg Co Inc – 707 Dayton Rd -Ottawa IL 61350 -Ph 815-433-5100 -Fax 815-433-5104 – B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – Using ESP Manager • Searching Server - Searches for Serial Servers on the network and brings back configuration information that will be displayed in the Server Properties window. • Uninstall Virtual COM - Allows virtual COM ports to be uninstalled from the ESP Manager window. • Monitor Port Status - Brings up a screen that displays the following information associated with the selected serial port: o Serial TX: Displays the number of bytes of data sent to the serial device since the IP connection was established. o Serial RX: Displays the number of bytes of data received from the connected serial device since the IP connection was established. o DTR/RTS: The DTR/RTS Port Status indicator displays the current logic state of the DTR and RTS hardware handshake (output) lines for the selected Serial Server port (1 = asserted, 0 = not asserted). o DCD/DSR/CTS: The DCD/DSR/CTS Port Status indicator displays the current logic state being received on the DCD, DSR and CTS hardware handshake (input) lines for the selected Serial Server port (1 = asserted, 0 = not asserted) o Status: Indicates whether the client software has made a connection with the Serial Server. o IP Address: Displays the IP address of the connected client when there is a client connection • Save Configuration File - Allows the user to save the current configuration information to a file with a .vcom extension. • Load Configuration File - Allows the user to load a configuration file. View Provides three viewing options for the ESP Manager screen: • Toolbar – allows the toolbar (directly under the menu bar) to be viewable or hidden • Status Bar – allows the Status Bar (at the bottom of the screen to be viewable or hidden • Split – allows the position of the split between the Icons pane and the Virtual COM List / Serial Server List panes to be dragged horizontally using the mouse 26 Chapter 4 Manual Documentation Number ESR90x-0508m B&B Electronics Mfg Co Inc – 707 Dayton Rd - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – Using ESP Manager Exit • Allows you to Exit the ESP Manager program Help • Accesses the About vcomui dialogue box, which indicates the sof...

Questo manuale è adatto anche per i modelli :
Giocattoli per bambini - ESR901 (1.22 mb)
Giocattoli per bambini - ESR902 (1.22 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie