Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Sony, Modello ICD-SX750

Produttore : Sony
File Size : 6.39 mb
File Nome : 4158672131.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere


da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


"LIMITER" is set to "ON" when you purchase the 1C recorder. 1 Press and hold &/MENU to enter the menu mode. The menu mode window will be displayed. 2 Press or to select"DETAIL MENU,"then press 1 ALARM l> "1 DETAIL MENU |> IREC MODE |MP3ima.| 3 Press or to select "LIMITER,"then press I USB CHARGE ION ^1 LIMITER |0N IPRE REC IOFF 4 Press or to select "ON," then press LIMITER ION I OFF 37“ Recording 5 Press ■ (stop) to exit the menu mode. HNote When'REC LEVEL" is set to "LOW A"HIGH "S-HIGH ,"the limiter function does not work. To cancel the limiter function Set"LIMTER"to"OFF"in step4. Recording a Few Seconds in Advance, before Starting to Record - the Pre-Recording Function The pre-recording function allows you to record sound sources for a maximum of 5 seconds prior to the point when the recording is started. Sounds for 5 seconds are buffered in the memory. This is useful to record during interviews or when making an open-air recording so that you will not miss the chance to start recording. Sounds for 5 seconds are buffered in the memory Press and hold # (record/ pause) to enter the recording the standby mode. Press# (record/pause). -► Recording starts. 1 Press and hold &/MENU to enter the menu mode. The menu mode window will be displayed. 2 Press or to select "DETAIL MENU,"then press 1 ALARM l> -1 IIDETAIL MENU > || IREC MODE 1 MP31123 .1 3 Press or to select "PRE REC,"then press I LIMITER ION ^1 PRE REC |OFF ISYNC REC IOFF 4 Press or to select "ON," then press IPRE REC OFF 1 u ON | OFF 5 Press ■ (stop) to exit the menu mode. 6 Select a folder. © Press Ed/menu to display the folder selection window. © Press or to select the folder in which you want to record messages, then press 39“ Recording 7 Press and hold • (record/pause) to enter the recording standby mode. Sounds for the last 0 to 5 seconds are buffered In the memory. -16dB -I-46-I-L LEV R 06 Iiraan3s (c-l) -1 hOOm C nrnraa ■ Displays that the sound for 0 to 5 seconds are buffered in the memory. 8 Press • (record/pause) to start recording. The standby for recording mode Is released, and recording starts. Sounds are saved for the 0 to 5 seconds prior to the point the button is pressed. 9 Press ■ (stop) to stop recording. Il Notes • If you start recording with pre-recording function using the built-in microphones, a click noise may be recorded when you press # (record/pause).To record with prerecording function, we recommend using an external microphone. • When the remaining recordable time is less than 10 seconds, the pre-recording function is disabled. • When 60 minutes have passed after the IC recorder entered the standby mode, the standby mode will be cancelled and recording stops. • If you stop recording before step 8, sounds buffered in the memory will not be saved. To cancel the pre-recording function Set'PRE REC"to"OFF"in step 4. Cutting out Low Frequency -the LCF Function When you set the LCF (Low Cut Filter) function to"ON"in the stop or recording mode, you cut out a frequency of lower than 200 Hz to reduce the roaring noise from wind, etc., this helps to record a sound source more clearly. The LCF function is set to "OFF" when you purchase the 1C recorder. 1 Press and hold &/MENU to enter the menu mode. The menu mode window will be displayed. 2 Press or to select "LCF (LOW CUT),"then press IREC LEVEL |HIGH«ff ^1 LCFfLOW CUT) |OFF IVOR IOFF .1 3 Press or to select "ON," then press |nna№vnnli!Mi^^1 HUH OFF 4 Press ■ (stop) to exit the menu mode. To cancel the LCF function Set "LCF (LOW CUT)" to "OFF" in step 3. 41 Starting to Record Automatically in Response to Sound - the VOR Function You can set the VOR (Voice Operated Recording) function to"ON,"to make the 1C recorder start recording when the 1C recorder detects sound, and pause when no sound is heard, eliminating recording during soundless periods. The VOR function is set to "OFF" when you purchase the 1C recorder. 1 Press and hold E3/MENU to enter the menu mode. The menu mode window will be displayed. 2 Press or to select "VOR," then press I LCF(LOW CUT) IOFF ^1 VOR IOFF I DISPLAY IELAPSE .1 3 Press or to select "ON," then press VOR IOFF | OFF 4 Press ■ (stop) to exit the menu mode. 5 Press • (record/pause). "I;I =t«f and 'Vi«];I"anpear in the display window. The recording starts when the 1C recorder detects sound.The recording pauses when no sound is detected andlTOST'and □0 flash. When the 1C recorder detects sound again, the recording starts again. To cancel the VOR function Set"VOR"to"OFF"in step 3. H Notes • The VOR function is affected by the sound around you. Set''REC LEVEL"in the menu according to the recording conditions. If recording is not satisfactory after you have changed the microphone sensitivity, or for an important recording, set''VOR''to''OFF''in the menu. • If you press # (record/pause) to pause_ recording during VOR recording, only at flash...

Questo manuale è adatto anche per i modelli :
Dettatura - ICD-SX850 (6.39 mb)
- ()
- ()

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie