Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso Emerson, Modello Hot1

Produttore : Emerson
File Size : 1.6 mb
File Nome : d2cdb926-a450-4050-a33c-2e1ad24ad428.pdf
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


This particular unit is not intended for commercial use. Make sure that all electrical wiring and connections conform to local codes. A standard 115-volt grounded electrical outlet is required under the sink for the dispenser’s electrical power. The wall outlet powering your dispenser must have power supplied to it continuously. This outlet must be fused and should not be controlled by the same wall switch that operates the disposer, unless you have a SinkTop Switch™ from InSinkErator®. Moving parts inside the tank causing a rattling noise is normal. This unit does not contain a drain plug and should not be installed where periodic draining is required, such as summer homes. WHAT YOU NEED TO GET STARTED Equipment Required: Compression fitting, T-fitting or saddle valve Adjustable wrench Phillips and flat blade screwdrivers Pencil Tape Measure Equipment You May Need: Hole punch Drill Hole saw Level Basin wrench If you intend to use the sprayer hole in your sink for your dispenser, you may need a basin wrench and a 1/8" plug or a 1/4" cap (not supplied ) for the faucet spray hose line. See Step 1-B. If you need to cut a mounting hole in your stainless steel sink, you may need a 11.4" - 11.2" hole saw made for cutting stainless steel or a hole punch. Consult a professional if you are drilling into a surface other than stainless steel. COMPONENTS IN THIS PACKAGE Wing Nut Mounting Nut Rubber Gasket Brass Nut Ferrule HOW TO USE THIS INSTRUCTION MANUAL These instructions are separated into main sections, indicated by numbers, and subsections, indicated by capital letters. The manual is setup this way to allow you to take a break at any point after completing a section or subsection without affecting the installation process. What you’ll see in the B Press valve lever down for about 20 instruction manual: 1 Valve Lever Property Damage: Do not connect electric power until tank is filled with water. Failure to do so my damage heating element or thermal safety fuse and will void the warranty. 2 seconds until water freely runs out of the spout. Hold valve open at lease 60 seconds to let the water run to flush out the lines. Water will be cold since tank has not been plugged in yet. 3 1 2 3 Provides a step-by-step narrative describing the installation step, with check boxes that can be marked as you progress through the installation. Contains simple illustrations that provide visual instruction to support the narrative. CAUTIONS, WARNINGS and DANGERS that will require your attention during the step. An imminently hazardous situation, which, if not avoided, will result in death or serious injury. A potentially hazardous situation, which, if not avoided, could result in death or serious injury. A potentially hazardous situation, which, if not avoided, may result in minor or moderate injury. A 115-volt grounded outlet within 30 inches of the dispenser is required to provide power to the tank. A minimum of 33.4" of space is required between the center of the dispenser head and splashboard/ wall in order for the appliance to operate properly. Note:The wall outlet for your dispenser must have power supplied to it continuously and must be fused. It should not be controlled by the same wall switch that operates your disposer. 3 DIMENSIONS DIMENSIONS 2." (6.4cm) Spout Spout Holder Maximum CountertopThickness for Mounting 3 Wire Power Cord 30" Long (76cm) (Opposite Side) Rubber Gasket MountingNut WingNut Width of Unit 5." 6" (15.2cm) 2" (5.1cm) 3" (7.6cm) (28.9cm) 4" (10.2cm) 8 2. " (6.5cm) 9 16 Valve Lever Slotted Set Screw (13.3cm) ." Copper Tube 16" Long (40.6cm) Cold Water Line START HERE PREPARATION Identify location for the dispenser. 1 A Required minimum from center of hole to wall 33.4" Maximum counter thickness (depth) 2" Check to make sure there is proper clearance for dispenser handle to be fully opened. Check to make sure counter is not too thick. Make sure there is a grounded electrical outlet under the sink. The wall outlet for your dispenser must have power supplied to it continuously and must be fused. It should not be controlled by the same wall switch that operates your disposer. B Turn off water supply. If using the sink sprayer hose hole, remove nut that connects sprayer hose at bottom of faucet. Using adjustable wrench, remove nut connecting sprayer washer flange in sprayer hole. Plug hose opening with either a 1/8" plug or a 1/4" cap (not supplied). If you have to drill through sink or countertop, you may need to rent or purchase the appropriate tools. C Required Hole Diameter 13.8" What if you don’t have a sprayer hole or don’t want to use it? Many homeowners replace the soap dispenser in their sink with an instant hot water dispenser. If drilling a hole into a stainless steel sink or counter top, you can cut a mounting hole for the dispenser with a hole saw for stainless steel, or you can use a hole punch. Consult a professional before drilling into a surface other than stainless...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie