Log:
valutazioni - 4, GPA: 4 ( )

Istruzioni per l'uso Perlick, Modello Z2148EMU

Produttore : Perlick
File Size : 35.13 kb
File Nome : _Z2148EMU.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Solution: Slowly turn Beer Flow Control Handle to ON position. Problem: Beer does not flow after keg is tapped. Probable Cause: Universal Empty Keg Sensor has locked up. Solution: Turn Beer Flow Control Handle to OFF position. Wait two or three seconds than slowly turn Beer Flow Control Handle to ON position. Probable Cause: Beer Flow Control Handle is OFF. Solution: Slowly turn Beer Flow Control Handle to ON position. Probable Cause: Universal Empty Keg Sensor is dirty. Solution: Clean Universal Empty Keg Sensor. Probable Cause: Out of gas. Solution: Reestablish gas flow. Problem: Excessive foam. Probable Cause: Beer temperature too high. Excessive beer flow rate. Beer is over-carbonated Solution: These problems are not caused by the Universal Empty Keg Sensor. Follow established procedures to correct the problem. 8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 Fax 414-353-7069 • Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • Form Z2148EMU 08.20.04 INSTALLATION AND OPERATING INSTRUCTIONS UNIVERSAL EMPTY KEG SENSOR Part No. 43739 The Perlick Universal Empty Keg Sensor shuts off the flow of beer when the keg empties. With the line full of beer, the foaming and resulting beer waste from changing kegs is eliminated. No. 43739 Universal Empty Keg Sensor IMPORTANT! To ensure your complete satisfaction, please read these instructions before using Perlick’s Universal Empty Keg Sensor. * U.S. Patent #5,630,411 INSTALLATION INSTRUCTIONS TAPPING AND CLEANING PROCEDURES INSTALLATION INSTRUCTIONS TAPPING AND CLEANING PROCEDURES 1. Disconnect keg coupler from keg. 2. Open faucet to relieve line pressure and close when flow ceases. 3. Disconnect beer line including seal washer EXISTING from keg coupler. BEER LINE 4. Connect beer line including seal washer to AND SEAL WASHER external thread of Universal Empty Keg Sensor and turn Beer Flow Control Handle to OFF position. (See Fig. 1). In this position the Universal Empty Keg Sensor acts as a shut-off valve. 5. Where fitted, remove retaining clip/spring and check ball from keg coupler center probe. 6. Insert seal washer supplied into coupling nut on Universal Empty Keg Sensor and couple to the keg coupler. P/N 43739 7. Connect keg coupler to keg and tap keg. UNIVERSAL 8. Turn Beer Flow Control Handle to CLEAN. EMPTY KEG SENSOR AND (See Fig. 3). SEALING 9. Open beer faucet. When solid beer WASHER appears, close the faucet. 10. Turn Beer Flow Control Handle ON. REMOVE (See Fig. 2). The line is full and ready CLIP/SPRING for service. AND CHECK BALL FROM COUPLER Warranty Perlick Products are fully guaranteed against defects in both material and workmanship for a period of one year from date of sale. Defective parts will be replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We are not responsible for parts damaged by alteration, unauthorized service, accident or abuse. All costs incident to replacement to include freight, labor and/or loss of sales are incidental to this warranty and must be borne by the user. Beer Flow Control Handle Operating Positions Fig. 2 ON Fig. 3 CLEAN Fig. 1 OFF 45° Cleaning Adapters No. 43657 No. 43681 Single Adapter Dual Adapter Filling the Lines the First Time 1. Turn Beer Flow Control Handle OFF. (See Fig. 1). 2. Tap fresh keg. 3. Turn Beer Flow Control Handle to CLEAN. (See Fig. 3). 4. Open the beer faucet. When solid beer appears, close the faucet. The line is full. 5. Turn Beer Flow Control Handle ON. (See Fig.2). The line is full and ready for service. When Tapping Fresh Kegs 1. Remove coupler from empty keg. 2. Turn Beer Flow Control Handle OFF. (See Fig. 1). 2. Tap fresh keg in normal manner. 3. Turn Beer Flow Control Handle to CLEAN. position. (See Fig. 3).Wait for five seconds then turn to ON position. (See Fig. 2). To Restart System If beer does not flow, first turn the Flow Control Handle to OFF. (See Fig. 1).Then turn Handle to the CLEAN position. (See Fig. 3).Wait for five seconds then turn the Handle to ON position. (See Fig. 2). To Clean 1. Untap Keg in usual manner. 2. Turn Beer Flow Control Handle OFF. (See Fig. 1). 3. Attach cleaning adapter. Use Perlick’s single cleaning adapter, No. 43657, if cleaning from faucet to keg. If two or more lines are cleaned, use Perlick’s dual cleaning adapter, No. 43681. 4. Turn Beer Flow Control Handle to CLEAN and clean as usual. (See Fig. 3). 5. After flushing, turn Beer Flow Control Handle OFF and retap keg. (See Fig. 1). 6. To restore service, see above instructions. ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie