Log:
valutazioni - 3, GPA: 4.7 ( )

Istruzioni per l'uso Perlick, Modello Z2148

Produttore : Perlick
File Size : 68.13 kb
File Nome : Z2148.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Probable Cause: Solution: Beer Flow Control Handle is in CLEAN position. Slowly turn Beer Flow Control Handle to ON position. Problem: Beer does not flow after keg is tapped. Probable Cause: Solution: Smart Coupler has locked up. First, turn Beer Flow Control Handle to OFF position then turn Beer Flow Control Handle to CLEAN position. Wait five seconds then turn Beer Flow Control Handle to ON position. Probable Cause: Solution: Beer Flow Control Handle is OFF. Turn Beer Flow Control Handle to CLEAN position. Wait five seconds then turn Beer Flow Control Handle to ON position. Probable Cause: Solution: Probe or Smart Coupler is dirty. Clean Smart Coupler. Probable Cause: Solution: Out of gas. Reestablish gas flow. Problem: Excessive foam. Probable Cause: Solution: Beer temperature too high. Excessive beer flow rate. Beer is over-carbonated These problems are not caused by the Smart Coupler. Follow established procedures to correct the problem. 8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 Fax 414-353-7069Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • Form Z2148 04.06.04 OPERATING INSTRUCTIONS SMART COUPLER with Empty Keg Sensor No. 26000FSmart Coupler with Empty Keg Sensor Part No. 26000F The Smart Coupler* combines a standard Perlick single-valve keg coupler with a specially-designed keg sensor that eliminates the line loss that normally follows every empty keg. Fresh kegs can be drawn off immediately. The beer lines are always full of beer. • Saves time • Reduces beer waste • Increases beer profits • Reduces aggravation IMPORTANT! To ensure your complete satisfaction, please read these instructions before using Perlick’s Smart Coupler. Retrofitting Single Valve Couplers Perlick single valve keg couplers can be retrofitted to function as Smart Couplers. Simply replace the probe with Perlick’s No. 40125 empty keg sensor. 1. Remove probe washer from bottom of probe. 2. Remove retaining screw and yoke assembly. 3. Lift probe out of body. 4. Install Perlick’s empty keg sensor. When replacing probe washer make sure the surface marked “up” faces the probe washer. Perlick’s Empty Keg Sensor No. 40125 (Probe Washer Not Included) * U.S. Patent #5,630,411 TAPPING and CLEANING PROCEDURES REPLACEMENT PARTS Fig. 2 ON Fig. 3 CLEAN Fig. 1 OFF 45° Filling the Lines the First Time 1. Turn Beer Flow Control Handle OFF. (See Fig. 1). 2. Tap fresh keg. 3. Turn Beer Flow Control Handle to CLEAN. (See Fig. 3). 4. Open the beer faucet. When solid beer appears, close the faucet. The line is full. 5. Turn Beer Flow Control Handle ON. (See Fig.2). The line is full and ready for service. When Tapping Fresh Kegs 1. Remove coupler from empty keg. 2. Turn Beer Flow Control Handle OFF. (See Fig. 1). 2. Tap fresh keg in normal manner. 3. Turn Beer Flow Control Handle to CLEAN. position. (See Fig. 3). Wait for five seconds then turn to ON position. (See Fig. 2). To Restart System If beer does not flow, first turn the Flow Control Handle to OFF. (See Fig. 1). Then turn Handle to the CLEAN position. (See Fig. 3). Wait for five seconds then turn the Handle to ON position. (See Fig. 2). To Clean 1. Untap Keg in usual manner. 2. Turn Beer Flow Control Handle OFF (See Fig. 1). 3. Attach cleaning adapter. Use Perlick’s single cleaning adapter, No. 43657, if cleaning from faucet to keg. If two or more lines are cleaned, use Perlick’s dual cleaning adapter, No. 43681. 4. Turn Beer Flow Control Handle to CLEAN and clean as usual. (See Fig. 3). 5. After flushing, turn Beer Flow Control Handle OFF and retap keg. (See Fig. 1). 6. To restore service, see above instructions. Warranty Perlick products are fully guaranteed against defects in both material and workmanship for a period of one year from date of sale. Defective parts will be replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We are not responsible for parts damaged by alteration, unauthorized service, accident or abuse. All costs incident to replacement to include freight, labor and/or loss of sales are incidental to this warranty and must be borne by the user. No. 43657 No. 43681 Single Adapter Dual Adapter 6 7 3 5 4 10 9 2 1 11 8 Item ........Part No. ....................Description 1. .......40125.....................Empty keg Sensor 2. .......43001A ..................Std. Yoke Assy. 3. .......2026 .......................Hex Nut 4. .......2068-1....................Tailpiece 5. .......157R2P..................Washer 6. .......23682-2P ...............Check Valve 7. .......31084-1..................Retaining Screw 8. .......31089-2P ...............“O” Ring (3 per assy.) 9. .......43061.....................Body w/relief valve 10. .......31088-2P ...............Bottom Seal Washer 11. .......31087-2P ...............Probe Washer Cleaning Adapters Beer Flo...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie