Log:
valutazioni - 5, GPA: 3.8 ( )

Istruzioni per l'uso Perlick, Modello DS Series

Produttore : Perlick
File Size : 331.24 kb
File Nome : Z2025A-12.08.03.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Electrical The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate. IMPORTANT WARNING To avoid compressor damage. DO NOT RUN UNIT IF CABINET HAS BEEN LAID ON ITS BACK If cabinet has been laid on its back for any reason, place it back into the upright position and allow it to stand for 24 hours before running unit. Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2025A 3 Rev. 12.05.03 Installation and Tapping – Direct Draw Dispensers Self-Contained Connecting the Keg Coupler (when Supplied by Perlick) ¦ Place one brown leather washer into black beer line connector hose on hex nut side. Screw connector to stainless steel beverage line on faucet standard. Tighten with a wrench, but do not over tighten. ¦ Make sure lever handle on the keg coupler is in the UP (untapped) position. Place one brown leather washer into wing nut end of black beer line connector hose and thread onto top of keg coupler. Hand tighten. ¦ Place clamp on one end of red air line. Push end over air valve located inside cabinet. Tighten clamp with screwdriver. Turn shut-off valve to OFF (horizontal) position. Place clamp on the other end of red air line and push over tailpiece on coupler. Tighten clamp with screwdriver. CAUTION: Do not use keg coupler as a handle to lift keg. Tapping a Single Valve Keg (Sankey): Single Valve Keg Coupler Step 2 Step 1 Step 3 ¦ Be sure beer faucet is in closed position. ¦ Align keg lugs with lug openings on bottom of coupler. ¦ Turn clockwise 1.4 turn. Pull handle out and down. Keg is now tapped. Open shut-off valve on air divider located inside of the cabinet. Important: Be sure to close this valve when untapping keg. Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2025A Rev. 12.05.03 4 Installation and Tapping – Direct Draw Dispensers Self-Contained Connecting the Regulator to the CO2 Cylinder ¦ Remove blue plug from regulator fitting. (Note: Do not remove the carbonic washer). ¦ Screw regulator onto gas cylinder valve. Tighten with wrench until vertically straight. Be sure that shut-off valve (black lever) on regulator is in the OFF (horizontal) position. ¦ Place a screw clamp over end of red air line and push onto regulator tailpiece. Tighten clamp with a screwdriver. REGULATOR CO2 PRESSURE GAUGE CO2 GAS DRUM (BLACK LEVER IN CLOSED POSITION) FITTING REGULATOR ADJUSTING SCREW FITTING FOR RED AIR HOSE SHUT-OFF VALVE HAND VALVE PERLICK PSI 10 50 0 60 20 40 30 Adjusting the CO2 Gas Flow ¦ Turn regulator adjusting screw counterclockwise until it turns freely. ¦ Turn hand valve counterclockwise on CO2 cylinder to the fully open position. ¦ Turn regulator adjusting screw clockwise until desired pressure is reached (approximately 12-15 lbs.). Tighten stop nut on adjusting screw. ¦ Open shut-off valve on bottom of regulator. CO2 Leak Test Dilute a small amount of liquid dishwashing soap and rub the soapy mixture around each connection. If bubbles appear, tighten connection. Replacing CO2 Gas Cylinder Turn CO2 hand valve clockwise until seated and close shut-off valve on regulator. ¦ Unscrew regulator from cylinder fitting. ¦ Replace carbonic washer (Part No. 157F2P), if needed and reattach regulator to filled cylinder. ¦ Turn CO2 hand valve counterclockwise until fully open. Turn regulator shut-off valve to open position. ¦ Adjust CO2 gas flow as required, turning clockwise for higher pressure. Proper CO2 Handling ALWAYS... ¦ Connect a regulator (reducing valve) to CO2 cylinder. ¦ Secure cylinder in upright position whether in storage or in use. ¦ Keep cylinder away from heat. Rupture disc vents at 122° F. maximum. ¦ Ventilate room after high pressure gas leakage. ¦ Check the last DOT test date on cylinder neck before filling. If more than five years old, the cylinder must be retested to DOT specifications. ¦ Be sure CO2 cylinder outlet fitting is free of dust or dirt before attaching regulator. ¦ Store CO2 cylinder and regulator assembly upright. ¦ Allow only properly trained and experienced personnel to handle high pressure gas. NEVER... ¦ Connect cylinder directly to a keg without a regulator (reducing valve). ¦ Drop or throw regulator or CO2 cylinder. ¦ Transport CO2 cylinder in a closed vehicle. ¦ Apply oil to a regulator. ¦ Shut off CO2 cylinder when not in use. You will not save gas by doing so! ¦ Allow untrained, inexperienced personnel to handle high pressure gas. Failure to heed this warning could result in personal injury or death. WARNING/SAFETY INSTRUCTIONS Beverage systems pressurized with carbon dioxide or nitrogen must be equipped with two safety relief valves; one at the cylinder r...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie