Istruzioni per l'uso Coway, Modello CHP-03AU

Produttore : Coway
File Size : 9.06 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Water systems using an in-line chlorinator should provide a minimum of 1minute chlorine contact time before the RO system. 2 This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of this system. Frequent analysis is encouraged. pErFOrMANCE DATA SHEET | CHp-03Ar32 Water Filtration System performance Data Sheet Water Filtration System performance Data Sheet brand: Mach Model: CHp-03AL This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, and 58. Substance Max. Allowable Concentration (mg/L) Average Influent (mg/L) Average Effluent (mg/L) Minimum Percent Reduction (%) Average Percent Reduction (%) Arsenic (Pentavalant) 0.010 0.05 0.006 79.1 87.7 Barium 2.0 10 1.4 83.5 86.6 Radium 226/228 5pCi/L 25pCi/L 5pCi/L N/A N/A Cadmium 0.005 0.031 0.002 89.0 92.7 Chromium (Hexavalent) 0.1 0.358 0.023 93.8 95.1 Chromium (Trivalent) 0.1 0.367 0.028 93.8 95.7 Lead 0.010 0.153 0.005 93.6 95.1 Nitrate/Nitrite 10 29.6 4.8 78.5 83.7 Selenium 0.05 0.117 0.003 96.0 97.8 TDS <187.5 741.5 57.8 91.5 92.2 Aesthetic Chlorine INNOSENSE . 50% 2.07 0.56 54.53 72.8 POST CARBON . 50% 1.96 0.53 55.0 72.8 VOC* INNOSENSE . 95% reduction 0.32 0.0077 95.70 97.6 POST CARBON . 95% reduction 0.298 0.005 96.0 98.3 While testing was performed under laboratory conditions, actual performance may vary. General Operating Information: Rated Capacity INNO SENSE FILTER 229 gallons (for VOC) 6,103 gallons (for Aesthetic Chlorine) POST-CARBON FILTER 212 gallons (for VOC) 1,179 gallons (for Aesthetic Chlorine) Min-Max operating pressure: 20 ~ 120 psi (1.4 ~ 8.4 kgf/cm2) Min-Max feed water temperature: 41 ~ 95 .F (5 ~ 35 .C) Rated Service Flow 0.07 GPM (for VOC) 0.5 GPM (for Aesthetic Chlorine) Daily Water Production Rate 43.7 GPD Product Efficiency Rating 29.5 % Electrical Requirements: 120 Vac / 60Hz • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. • Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user responsibility, and parts and service availability. • The influent water to the system shall include the following characteristics: o No organic solvents o Chlorine: < 2 ppm o pH:7-8 o Temperature: 41 ~ 95 .F (5 ~ 35 .C) o Iron: < 2 ppm o Turbidity: < 1 NTU o Hardness: < 1000 mg/L Others Others • For parts and service availability, please contact your local dealer or Coway. • This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 2.8 kgf/cm2 (40 psi) or greater. • A nitrate/nitrite sampling kit should be used to monitor the nitrate/nitrite levels in your product drinking water at least every six months. Kits maybe purchased from your local dealer or Coway. • This system has been tested for the treatment of water containing pentavalent arsenic (also know as As(V), As(+5), or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of this Performance Data Sheet for further information. • Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage. • The product water should be tested every 6 months to ensure that the contaminants are being reduced effectively. Please contact your local dealer or Coway to initiate this service. • This reverse osmosis system contains a replaceable treatment components, critical for the effective reduction of total dissolved solids and that product water shall be tested periodically to verify that the system is performing properly. Replacement of reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure the same efficiency and contaminant reduction performance. • The ...

Questo manuale è adatto anche per i modelli :
Dispenser - CHP-03AR (9.06 mb)
Dispenser - CHP-03AL (9.06 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie