Istruzioni per l'uso APC, Modello INROW RP ACRP502

Produttore : APC
File Size : 944.86 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Electrical Data SKU Voltage MCA MOP LRA RLA FLA Hz Power (kW) ACRP100 200 - 240 80.1 100 160* 50.0 N/A 50/60 19 ACRP101 460 - 480 39.9 50 139* 23.2 N/A 60 21 ACRP102 380 - 415 N/A N/A 139* 23.2 32* 50/60 20 ACRP500 200 - 240 46.8 50 N/A N/A N/A 50/60 14 ACRP501 460 - 480 24.8 30 N/A N/A N/A 60 14 ACRP502 380 - 415 N/A N/A N/A N/A 24** 50/60 15 Note: Above data is based on maximum operating condition*Local or national codes may require the installation of an external disconnect. The disconnect must be rated properly for the equipment. **Local or national codes may require the installation of external disconnects. Two disconnects would be required and must be rated properly for the equipment. MCA - Minimum Circuit AmpacityMOP - Maximum Overcurrent Protection LRA - Locked Rotor AmpsRLA - Rated Load AmpsFLA - Full Load Amps InRow RP Technical Data Manual Dimensional Data InRow RP Assembled Module na2465a Dimensions are shown in mm (in). InRow RP Technical Data Manual SX to VX Height Adapter SX to 48U SX Height Adapter Dimensions are shown in mm (in). na2445a na2446a InRow RP Technical Data Manual Piping and Mechanical Connections Chilled Water Piping Diagram Flex hose or copper Circuit setter (field-installed) Copper tubing Hose end drain with cap na2572a Bottom piping Top piping InRow RP InRow RP InRow RP InRow RP Return Return Supply Supply Y-strainer with 20 mesh screen (field Isolation valve installed)* *Blow down may be installed on Y-strainer. InRow RP Technical Data Manual Top Chilled Water Piping Access (top view) Note: Top or bottom entry can be chosen individually for each type of connection, i.e. power, condensate drain, humidifier water supply, chilled water supply and chilled water return. Top piping configuration will have the same valves and strainers as bottom piping configuration. 0 REAR—HOT AISLE 40 ( 1.58) 40 ( 1.58) 59 ( 2.32) 59 ( 2.32) 554 ( 21.81) 554 ( 21.81) na2274a 112 ( ) 4.4160 6.3( ) 0 73 ( ) 2.86 105 ( ) 4.12737 ( ) 29.02325 ( ) 12.81380 ( ) 14.98635 ( ) 24.99177 ( ) 6.97176 ()6.92211 ()8.29FRONT—COLD AISLE Dimensions are shown in mm (in) . Chilled water supply . Chilled water return . Trough for communication cables . Power connections—dual feed . Humidifier supply . Condensate drain . InRow RP Technical Data Manual Bottom Chilled Water Piping Access (bottom view, looking up) REAR—HOT AISLE REAR—HOT AISLE 18.86) 15.63) 13.58) 13.58) na2104a 184 ( ) 7.240 187 ( ) 7.35397 ( 479 ( 345 ( 345 ( 141 ()5.54176 ()6.9157.25 (2.25) 425 ( ) 16.72138 ( ) 5.430 172 ( ) 6.77 156 ( ) 6.13796 ( ) 31.34 FRONT—COLD AISLE Dimensions are shown in mm (in). Water supply to chiller . Water supply from chiller . Condensate overflow . Communication connections—27.80 mm (1.09 in) . Power connections—dual feed . Condensate drain . Humidifier supply . InRow RP Technical Data Manual Air-cooled Piping Diagram Bottom piping Top piping na2543a Hot gas Liquid Hot gas RP RPReceiver Receiver Condenser Condenser Liquid Note: Shutoff valves shown nearest to the condensers are not supplied by APC. Pitch in direction of refrigerant flow; 4 mm per m Pressure relief . (0.5-in per 10 ft) valve Shutoff valves P-trap Head pressure control valve S-trap Check valve Inverted P-trap All lines are Type L copper tubing. Note: Route piping through the top or bottom of the InRow RP. Note: Trap the vertical discharge line every 6 m (20 ft) to ensure proper oil return. Note: The maximum piping run is 61 m (200 ft) equivalent length. Size the piping pursuant to accepted refrigeration practice. Warning: Do not install the air-cooled condenser below the indoor equipment. The condenser must be positioned above or at the same level as the equipment to ensure proper function. InRow RP Technical Data Manual InRow RP Technical Data Manual 33 Air-cooled Piping Access (top) Dimensions are shown in mm (in). . Refrigerant discharge line . Refrigerant liquid line . Pressure relief valve discharge line . Trough for communication cables . Power connections . Humidifier water supply . Condensate drain na2071a 547 (21.54) 558 (21.97) 123 (4.84) 75 (2.95) 73 (2.86) 40 (1.58) 47 (1.85) 105 (4.12) 325 (12.78) 380 (14.94) 738 (29.04) FRONT—COLD AISLE REAR—HOT AISLE Air-cooled Piping Access (bottom view, looking up) REAR—HOT AISLE 479 ( 18.86) 397 ( 15.63) 345 ( 13.58) 345 ( 13.58) 0 184 ( 7.24) 187 ( 7.35) 141 (5.54) 176 (6.91) 57.25 (2.25) 425 ( 16.72) 138 ( 5.43) 172 ( 6.77) 156 (6.13) 796 ( 31.34) na2072a FRONT—COLD AISLE . Pressure relief valve access—27.80 mm (1.09 in) . Refrigerant liquid line . Refrigerant discharge line . Condensate overflow—50.00 mm (1.97 in) . Communication connections—27.80 mm (1.09 in) . Power connections . Condensate drain . Humidifier water supply Dimensions are shown in mm (in). InRow RP Technical Data Manual Air-Cooled Condensers Mechanical Data SKU Ambient Temp Sound Pressure (dbA)* Sound Pressure (dbA) ** Air Quantity Fan Unit Connection Size Weight Capacity l/s (CFM) Qty. kW Hot Gas Liquid Kg (Lbs) MBH/1FTD kW/1C TD AC...

Questo manuale è adatto anche per i modelli :
Dispenser - INROW RP ACRP100 (944.86 kb)
Dispenser - INROW RP ACRP501 (944.86 kb)
Dispenser - INROW RP ACRP500 (944.86 kb)
Dispenser - INROW RP ACRP102 (944.86 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie