Log:
valutazioni - 4, GPA: 3.3 ( )

Istruzioni per l'uso Bunn, Modello ULTRA-2

Produttore : Bunn
File Size : 2.35 mb
File Nome : 98263d56-37cb-45ae-9637-1880730d98c3.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Two screens will appear for left and right. The operator can scroll through a range of a minimum of1 (ULTRA) to a maximum of 16 (ICE). Factory default is 10. SET THICKNESS ? NO YES MIN LEFT 9 MAX MIN RIGHT 5 MAX 32080 032702 10 Test Augers This function tests the operation of forward and reverse of each auger motor. Left auger appears first. Press the ICE hidden switch to toggle between OFF, FORWARD and REVERSE. Press GOURMET hidden switch to repeat the operation for the right auger motor. A one minute time out will return to the Home Screen. TEST AUGERS ? NO YES LEFT AUGER TEST NEXT FORWARD Select NEXT to repeat process for Right Auger Test. LEFT AUGER TEST NEXT OFF LEFT AUGER TEST NEXT REVERSE Set Time and Date Selecting YES (ICE) allows the operator to set the DATE (YY MM DD) and TIME (HR MIN SEC) for display on the Home Screen. SET DATE TIME ? NO YES YEAR 2002 (-) NEXT (+) MONTH 1 (-) NEXT (+) MONTH DAY 4 (-) NEXT (+) HOUR 10 AM (-) NEXT (+) MINUTE 45 (-) NEXT (+) SECOND 30 (-) NEXT (+) 32080 021202 11 Password From this screen, the operator must know the password before moving on to the remaining functions. The range is from 0 - 9999 with the factory default being 0. PASSWORD 0 (-) NEXT (+) Set Night Time/Set Day Time The setting of the Day/Night mode allows the dispenser to “power down” during off hours. The bottom corners displaying “ICE” will change to “CHILL” during the night mode. During the night mode, the product will be kept chilled to below 35°F. “ICE” reading will return after night mode elapses. With “OFF” representing 12:00 AM, the operator can scroll to the times desired for the night time mode to begin and end. (Some early models displayed the word “DISABLED” in place of the word “OFF”). SET NIGHT TIME (-) OFF (+) SET DAY TIME (-) OFF (+) 12 NIGHT TIME MODE CHILL CHILL 32080 022003 This feature allows the machine to defrost the product during day time operation. The defrost minutes setting will select the defrost time period. The freeze minutes setting will select the freeze time between defrost periods. These modes when activated will function anytime the machine is in day mode operation. The machine will automatically stay in the freeze mode for 2 hours after waking up from the night time mode. (This feature was not offered on some early models). FREEZE MINUTES (-) 60 (+) DEFROST MINUTES (-) OFF (+) Preventive Maintenance Complete? This function is used to reset a reminder message Preventive Maintenance Due every six months. The machine will not shut down if service is not performed. When the service is performed and the message is answered YES (ICE), the time and date is recorded for another six months to elapse. This feature can be DISABLED by pressing (-) ULTRA hidden switch. (Some early models displayed the word “ENABLED” in place of the word “ON”). PM COMPLETE ? NO YES 6 MONTH PM (-) ON (+) 13 32080 022003 Day To Clean Off (formerly Days....Disabled) This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is 0 or DISABLED. Selecting -or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKOUT. On the day selected, the display will toggle between DATE & TIME and CLEAN DUE TODAY. The dispenser will lock into night mode at midnight if “Clean Lockout” is activated. To reset the Clean Due Today message or lockout, two functions must be performed. Either power off the dispenser using the I/O (ON/OFF) switch and allow the barrels or cooling drums to warm over 50°F, or scroll to the Cleaning Guide and perform the cleaning service. The barrels will warm to over 50°F when cleaned with warm water and the message will disappear. DAY TO CLEAN OFF (-) NEXT (+) DAYS TO CLEAN 14 (-) NEXT (+) CLN MESSAGE ONLY (-) NEXT (+) CLEAN LOCKOUT (-) NEXT (+) Consistency Adjust Lock This is an option of locking the Set Consistency function by selecting + (YES) or -(NO). YES THICK ADJUST (-) NEXT (+) NO THICK ADJUST (-) NEXT (+) 32080 022003 14 Switches Enabled This function allows the operator to lockout the touch pad. Selecting + (ON) provides no time delay on switches except for the center (GOURMET) hidden switch. Selecting - (LOCKOUT) provides a five second hold to wake up the touch pad and a two minute time frame from last button pressed to make adjustments before returning to sleep mode (five second hold). (Some early models displayed the word “ENABLED” in place of the word “ON” and the word “DISABLED” in place of the word “LOCKOUT”). SWITCHES (-) ON (+) SWITCHES (-) LOCKOUT (+) Set Password This is the function to set the password using a range of 0 to 9999 (the factory default is 0). When the password is set, the operator can only access the first four functions: Cleaning Guide, Set Consistency, Test Augers and Set Date & Time. SET PASS WR 0 (-) NEXT (+) SET PASS WR 9999 (-) NEXT (+) 32080 022003 15 Restore Default? Answering YES (ICE) to this function returns th...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie