Log:
valutazioni - 2, GPA: 3.5 ( )

Istruzioni per l'uso Bunn, Modello ULTRA-1

Produttore : Bunn
File Size : 3.6 mb
File Nome : 40563.0000.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Use at least two people to lift or move the dispenser. 1. Set the dispenser on a sturdy counter top. The dispenser requires a minimum of 6.0” air clearance at the rear of the dispenser. For optimum performance, do not let warm air from surrounding machines blow on the ULTRA dispenser. NOTE – The dispenser should be level or slightly lower in front for proper operation. 6.0” MIN. 2. Remove all shipping material, including the compressor support eyebolt, the cooling drum supports, the “Do Not Lift Here” signs from the cooling drums, and the “Rinse Before Using” signs from the hopper(s). For models without PAF (Powder Auto-Fill), proceed to step #7. 3. Remove the rear plastic plug from the trim strip between the hopper drip trays and loosen the auger motor cover screws. 4. Place PAF platform assembly on top of the motor covers and install support rod into hole in trim strip. 5. Tighten support rod from top of platform. Retighten motor cover screws. 6. Plug RCA cord into ULTRA base unit. Proceed with steps 7 thru 12. 8. Press the seals firmly into place. 7. Install each hopper seal over the flange at the rear of the cooling drums as shown. 40563 110207 Initial setup (cont.) 9. Align the auger shaft with the flat fin of the auger. Push the augers as far as they will go and rotate them so the flat fin is facing up. 10. Install auger nose bushing into inside front of hopper. 11. Thoroughly rinse the hoppers and install them over the augers and cooling drums. 12. Slide the hopper(s) into place and push down until the hopper lock plunger snaps into place. For models without PAF, proceed to step 15. 14. Install PAF unit onto platform and plug power cord into rear of platform. Plug platform power cord into proper outlet. (Refer to PAF manual for water con- nections)(Proceed to step 17) 13. For models with PAF, install level probes into slots at top rear of PAF hoppers. 16. Plug in the hopper lid lamp cord(s). 15. Set the lid(s) on the hopper(s). Lift slightly and slide back or front for filling. 17. Assemble the drip tray. 40563 110207 OPERATING CONTROLS ULTRA-1 There are three of these switches that will be used for the operation of the dispenser. 1 2 3 P3932 4 1. switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming. 2. (upper right corner) This is used to turn the auger motor to AUGER ON, AUGER OFF or AUGER REFILL ON. (Refill only applicable when installed) 3. (lower right corner) This is used to turn the ice control to OFF, ICE or CHILL. 4. Hidden buttons used for Programming. 40563 041108 OPERATING CONTROLS ULTRA-2 There are five of these switches that will be used for the operation of the dispenser. 1 P3677 6 2 3 4 5 1. switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming. 2. (bottom left corner) This is used to turn the left side auger motor to AUGER ON, AUGER OFF or AUGER REFILL ON. (Refill only applicable when installed) 3. (bottom left corner) This is used to turn the left side ice control to OFF, ICE or CHILL. 4. (bottom right corner) This is used to turn the right side auger motor AUGER ON, AUGER OFF or AUGER REFILL ON. (Refill only applicable when installed) 5. (bottom right corner) This is used to turn the right side ice control to OFF, ICE or CHILL. 6. Hidden buttons used for Programming. 40563 041108 USING THE DISPENSER FOR GRANITA-TYPE PRODUCTS 1. Lift the lid slightly for the selected hopper and slide back to gain access to the hopper. 2. Place the pre-mixed liquid product in the selected hopper. 3. a. Press and release the (ON/OFF) switch to power on the dispenser. b. Press and release the appropriate (ON/OFF) switch to start the Auger Motor and to turn on AutoFill when applicable. c. Press and release the (OFF/ICE/CHILL) switch and select ICE to begin the cooling process for the selected hopper. 4. Wait for the liquid to freeze to the desired consistency. HINTS – Bunn-O-Matic recommends that the product in the dispenser be thawed each day, usually overnight. The ice granules get too large and a consistent product is difficult to maintain if left frozen for an extended period of time. Set the NIGHT mode for a few hours each night and return it to the DAY mode when the product has thawed sufficiently. You’ll know it is in the NIGHT mode because the display will indicate NIGHT MODE, and the hopper light(s) will turn off. USING THE DISPENSER FOR COLD LIQUID PRODUCTS 1. Lift the lid slightly for the selected hopper and slide back to gain access to the hopper. 2. Place the pre-mixed liquid product in the selected hopper. 3. a. Press and release the (ON/OFF) switch to power on the dispenser. b. Press and release the appropriate (ON/OFF) switch to start the Auger Motor and ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie