|
Facilità d'uso
Carpeting and other heat insulating surfaces block proper air circulation which may cause overheating of the charger and battery pack. If smoke or melting of the case are observed unplug the charger immediately and do not use the battery pack or charger. Use of an attachment not recommended or sold by Bosch may result in a risk of fire, electric shock or injury to persons. Battery Care When batteries are not in !WARNING To prevent fire or injury tool or charger, keep them !WARNING when batteries are not in away from metal objects. For example, to tool or charger, always place protective protect terminals from shorting DO NOT cap onto end of battery pack. Protective place batteries in a tool box or pocket with cap, guards against terminal shorting. nails, screws, keys, etc. Fire or injury may DO NOT PUT BATTERIES INTO FIRE OR result. EXPOSE TO HIGH HEAT. They may explode. -5 BM 2610925941 6-05 6/10/05 10:21 AM Page 6 Battery Disposal !WARNING Do not attempt to disas semble the battery or remove any component projecting from the battery terminals. Fire or injury may result. Prior to disposal, protect exposed terminals with heavy insulating tape to prevent shorting. NICKEL-CADMIUM BATTERIES If equipped with a nickel-cadmium battery, the battery must be collected, recycled or disposed of in an environmentally sound manner. “The EPA certified RBRC Battery Recycling Seal on the nickel-cadmium (Ni-Cd) battery indicates Robert Bosch Tool Corporation is voluntarily participating in an industry program to collect and recycle these batteries at the end of their useful life, when taken out of service in the United States or Canada. The RBRC program provides a convenient alterative to placing used Ni-Cd batteries into the trash or the municipal waste stream, which may be illegal in your area. Please call 1-800-8-BATTERY for information on Ni-Cd battery recycling and disposal bans/restrictions in your area, or return your batteries to a Skil/Bosch/Dremel Service Center for recycling. Robert Bosch Tool Corporation’s involvement in this program is part of our commitment to preserving our environment and conserving our natural resources.” NICKEL-METAL HYDRIDE BATTERIES If equipped with a nickel-metal hydride battery, the battery can be disposed of in a municipal solid waste stream. -6 BM 2610925941 6-05 6/10/05 10:21 AM Page 7 Symbols IMPORTANT: Some of the following symbols may be used on your tool. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the tool better and safer. Symbol Name Designation/Explanation V Volts Voltage (potential) A Amperes Current Hz Hertz Frequency (cycles per second) W Watt Power kg Kilograms Weight min Minutes Time s Seconds Time Diameter Size of drill bits, grinding wheels, etc. n0 No load speed Rotational speed, at no load .../min Revolutions or reciprocation per minute Revolutions, strokes, surface speed, orbits etc. per minute 0 Off position Zero speed, zero torque... 1, 2, 3, ... Selector settings Speed, torque or position settings. I, II, III, Higher number means greater speed Infinitely variable selector with off Speed is increasing from 0 setting Arrow Action in the direction of arrow Alternating current Type or a characteristic of current Direct current Type or a characteristic of current Alternating or direct current Type or a characteristic of current Class II construction Designates Double Insulated Construction tools. Earthing terminal Grounding terminal Warning symbol Alerts user to warning messages Ni-Cad RBRC seal Designates Ni-Cad battery recycling program A0 A0 A0 A0 A A A This symbol designates This symbol designates that this tool is listed to that this tool is listed by Canadian Standards by Underwriters Laboratories. Underwriters Laboratories. This symbol designates that This symbol designates this tool is listed by that this tool is listed by Underwriters Laboratories, the Canadian Standards and listed to Canadian Association. Standards by Underwriters Laboratories. This symbol designates that this tool complies to NOM Mexican Standards. -7 BM 2610925941 6-05 6/10/05 10:21 AM Page 8 Functional Description and Specifications !WARNING Disconnect battery pack from tool or place the switch in the locked or off position before making any assembly, adjustments or changing accessories. Such preventive safety measures reduce the risk of starting the tool accidentally. Cordless Drills/Drivers RUBBERIZED GRIP BIT AND BIT STORAGE BATTERY RELEASE TABS BATTERY PACK FORWARD/REVERSING LEVER & TRIGGER LOCK VARIABLE SPEED TRIGGER SWITCH GEAR SHIFTER ADJUSTABLE CLUTCH KEYLESS CHUCK FIG. 1 VENTILATION OPENINGS BIT STORAGE ADAPTER Model number 32609 32612 32614 32618 Voltage rating 9.6 V 12 V 14.4 V 18 V No load speed 1 n0 0-300/min n0 0-400/min n0 0-400/min n0 0-400/min No load speed 2 n0 0-1000/min n0 0-1200/min n0 0-1200/min n0 0-1300/min Maximum Capacities Chuck size 3/8" 3/8 3/8" 3/8" Screw sizes #12 x 3" #14 x 3" #16 x 3" #16 x 3...
Questo manuale è adatto anche per i modelli :Trapani e shuropopverty - 32614 (1.24 mb)
Trapani e shuropopverty - 32618 (1.24 mb)
Trapani e shuropopverty - 32609 (1.24 mb)