Produttore : American Dryer
File Size : 152.46 kb
File Nome : 8100-72x.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


removal of cover: A) Loosen tamper-proof screws using wrench supplied, turn clockwise (donot remove). Located under bottom intake vent. B) To remove, place a hand on each side of cover and lift upward, then pull off. Dryers should be placed at least 2 feet (61cm) apart and at least 12” (30cm) 2. from washbasin. Do not install dryer over washbasin. Automatic dryers should be at least 18” (46cm) above any projection which may interfere with the operation of the automatic sensor. Hold the backplate to the wall at the suggested mounting height. Measure from bottom edge of backplate to the floor ( ref. Dimension “A” Fig. 1): cHiLDren men WOmen (depends on age) DiSABLeD A-T - Hand Dryer 42” (107cm) 40” (102cm) 30-40” (76-102cm) 34” (86cm) Mark the locations of the four mounting holes and the conduit entrance 3. location on the wall. (The conduit entrance is the proper hole diameter for 1/2 inch (13mm) conduit.) Fasten the backplate to the wall where previously marked. 4. RECOMMENDATION: Wood wall – No. 16 (M8) wood screws, 2 3/4” (70mm) longcement or brick – 1/4” (M6) stud expansion bolts, 3” (76mm) long Hollow wall – 1/4” (M6) toggle bolts, length depends on wall thickness Run service wire to the dryer location and connect to the terminal block. 5. IMPORTANT: All units must be supplied with 3 wire service. Use No. 12 wire or larger, as required by local electrical code. The ground wire must be connected to the dryer backplate. Unit must be installed by a qualified licensed electrician. cOnnecT TO A DeDicATeD circUiT nOT TO exceeD 20 AmpS. Dryers located in shower rooms or other wet locations should be equipped with ground fault interrupter(s). 6. carefully replace the cover using two tamper-proof bolts supplied, turn counter-clockwise. Be careful not to damage circuit board or sensor. Apply a bead of caulk around the edge of the cover to the wall. AMERICAN DRYER, INC. 33067 INDUSTRIAL ROAD, LIVONIA, MI 48150, U.S.A. Telephone (734) 421-2400 • Fax (734) 421-5580• Email: sales@americandryer.comRevised MAY 2011 OWNER’S MANUAL “ A-T” Series HAND AND HAir DrYErS For InstallatIon or servIce assIstance Please call 421-2400(734) or email: sales@americandryer.com ImPortant: Have Model & Serial No. ready model #______ serIal #______ AmericAn DrYer LimiTeD WArrAnTY - “A” All dryer parts are warranted to the original consumer purchaser to be free from defects in material and workmanship for a period of ten (10) years from the date of purchase from manufacturer, in the U.S.A. Outside of the U.S.A., two (2) years. The electronic sensor is warranted for five (5) years. Outside of the U.S.A., two (2) years. We will replace FREE OF CHARGE, during the warranty period, any warranted part which proves defective in material and/or workmanship under normal installation, use, and service, excluding normal wear. Replacement parts can be obtained by returning the part, TRANSPORTATION CHARGES PREPAID. You must notify factory prior to returning part or dryer. Any damage to this dryer as a result of misuse, abuse, neglect, accident, improper installation, unauthorized repairs, or any other use violative of instructions furnished by us, WILL VOID THIS WARRANTY. THIS LIMITED WARRANTY IS THE SOLE WARRANTY ON OUR PRODUCTS, AND WE DISCLAIM AND EXCLUDE ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. OUR LIABILITY SHALL NOT EXCEED IN ANY EVENT THE REPLACEMENT OR SALE PRICE OF THE ALLEGEDLY NONCONFORMING PRODUCT AND SHALL EXCLUDE LABOR CHARGES. TO THE EXTENT PERMITTED BY LAW WE SHALL NOT BE LIABLE FOR ANY LOSS, COST, EXPENSE, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER BASED UPON WARRANTY (EXPRESS OR IMPLIED), CONTRACT, NEGLIGENCE OR STRICT LIABILITY AND ARISING IN ANY WAY IN CONNECTION WITH THE DESIGN, MANUFACTURE, SALE, USE OR REPAIR OF THE PRODUCT. THermOSTAT TerminAL BLOcK BAcKpLATe DO NOT MOUNT TOP SIDE DOWN 3/4” 10-3/4” (273mm) 9-1/4” (235mm) 8” (203mm) 1” (25mm) 7-1/16” (179mm) 8-9/16” (217mm) 3/4”(19mm) 2-3/4” (70mm) 1” (25mm) conduit entrance 7/8” (22mm) Dia. Hole conduit entrance 7/8” (22mm) Dia. HoleFor Surface Wiring 4 mounting Holes5/16” (8mm) Dia. Hole 1-1/16” (27mm) ^ ^ ^ ^ ^ ^^^ ^ ^^ ^^ ^^ ^^ ^^ ^ ^ ^ TOp “A” FLOOR Figure 1 SenSOr ADJ. pOT FAn HeATinG eLemenT mOTOr Figure 2 DISCONNECT POWER BEFORE SERVICING DESUNA LA ELECTRICIDAD ANTES DE HACER REPARACIONES WArninG: pArTS LiST FOr “A-T” mODeLS FIgure3 SeNSitivity adjuStMeNt DR227 THERMOSTAT (CIRCUIT BREAKER) SP216C MOTOR, 115V, 60 HZ (A60, A70) SP217C MOTOR, 208-240V, 60 HZ (A80) CI232 SECURITY SCREW & SPECIAL ALLEN WRENCH DR239-P SENSOR COMPLETE, 110-240 VOLT CI202 COVER, MUST SPECIFY MODEL #, PUSH DR218 HEATING ELEMENT (A60) BUTTON OR AUTOMATIC. DR219 HEATING ELEMENT (A70) COMPLETE WITH ACCESSORIES. DR220 HEATING ELEMENT (A80, A50) SerVice AnD mAinTenAnce OF YOUr DrYer Each component used in your dryer has been designed to provide years of trouble free ...

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie