|
Facilità d'uso
For more information on venting kits and accessories, please call 1-800-GE-CARES. Stacked Dimensions (in inches) 80-1/8 27 13 28-3/4 Pedestal Dimensions (in inches) SBSD137HWW - white This optional 13" pedestal raises the door opening and height of the washer or dryer. Feet on 13" pedestal allow it to adjust to 13-3/8" height. Listed by Underwriters Laboratories Specification Revised 1/08 360459 DBVH520EJ GE® 7.0 Cu. Ft. Super Capacity Frontload Electric Dryer DBVH520EJ GE Dryer Vent GE® 7.0 Cu. Ft. Super Capacity Frontload Electric Dryer Dryer Exhausting Information – Metal Duct Only For complete information, see installation instructions packed with your dryer. Best Performance Ducting Materials: For best performance, this dryer should be vented with 4” diameter all A B 2-1/2 4 Maximum Length Maximum Length rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” of 4" Dia. of 4" Dia. venting can be used, but it will reduce the maximum recommended duct length. Rigid Metal Duct Flexible Metal Duct Exhaust Length Calculation: Exhaust Hood Type Exhaust Hood Type 1. Determine the number of 90° turns needed for your installation. If you exhaust to the Number side or bottom of dryer, add one turn. of 90° B B 2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated is Turns A 2-1/2" A 2-1/2" 4" Opening shown in the table. The maximum length for flexible ducts are less than for rigid duct. Opening 4" Opening Opening A turn of 45° or less may be ignored. Two 45° turns within the duct length should be 0 90 ft. 60 ft. 55 ft. 45 ft. treated as a 90° elbow. 1 60 ft. 45 ft. 40 ft. 30 ft. Front Loading A turn over 45° should be treated as a 90° elbow. 2 45 ft. 35 ft. 30 ft. 20 ft. Dryers 3 35 ft. 25 ft. 20 ft. 15 ft. Exhausting the dryer to the outside is strongly recommended to prevent large amounts 4 25 ft. 15 ft. 15 ft. 10 ft. of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed Down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4" opening dampered wall cap. For more information on venting kits and accessories, please call 1-800-GE-CARES. Listed by Underwriters Laboratories Specification Revised 1/08 360459 DBVH520EJ GE® 7.0 Cu. Ft. Super Capacity Frontload Electric Dryer Features and Ben...
Questo manuale è adatto anche per i modelli :Friggitrici - DBVH520EJ (382.92 kb)
Friggitrici - DBVH520EJ (382.92 kb)