Produttore : Chauvet
File Size : 727.56 kb
File Nome : ch-324_ug-156.pdf
|
Facilità d'uso
u If the unit is functional but the lamp does not light - the lamp may require replacing. u If after trying the above, you still have a problem, contact CHAUVET. Contact Chauvet USA Technical Assistance: 1-800-762-1084 (954) 929-1115 E-Mail tech@chauvetlighting.com Caution Do not obstruct the air vents. Do not touch unit or lamps while hot. Never put any objects through the air grill on the top of the unit. No user serviceable parts inside. Please refer to CHAUVET for service. Power Connections The unit is supplied with a power plug appropriate to its voltage and destination. Should any other connections be required they must be carried out with the following configuration. Earth = Green/Yellow cable Neutral = Blue cable Gobo Splash CH-324Users Guide Please read these instructions carefully before use Live= Brown cable In the USA & Europe, it is required that all plugs are 3-pin type i.e. with Earth/Ground connection. In the UK, it is required that all mains plugs are fitted with 5A fuses. Technical Specifications Power 120V~60Hz AC 230V~50Hz AC Fuse 20mm Glass 5A Fast Blow 20mm Glass 3.15A Fast Blow Lamps 1 X 24V 250W Part No. ELC3 24V 250W (300 Hrs) Dimensions 368 x 368 x 152mm / 14.5 x 14.5 x 6 in Weight 8.5 kg / 18.7 lbs User Information (Please complete for your records) World-wide Headquarters: 3000 North 29th Ct., Hollywood, Florida, USA 33020 Tel: +1-954-929-1115 Fax: +1-954-929-5560 800-762-1084 Data Purchased : / / Serial No. : Dealer Stamp : Model : CH-324 Gobo Splash At the Rear: uMounting Bracket Sound sensitivity knob uLamp Replacment Cover uLenses/Reflectors /3 dichroic prism Fig 1 • Screw Cap Fuseholder Introduction Congratulations on the purchase of your new CHAUVET lighting effect. We are confident you will enjoy many trouble free hours with this unit .To assist with the care and use of the product, we have prepared this short guide. Operation Before connecting this unit to the mains power supply for the first time you must first install the lamps. (See Replacing Lamps for details). This lighting effect has been designed to function on a mains power supply of either 120V~60Hz or 230V~50Hz and has been fitted with a suitable power plug for use with your local voltage. Check the label and voltage selector switch (if fitted) on the unit and the power plug for the correct voltage. When connected to the mains power supply the unit should illuminate. The unit will also begin to run through its pre-programmed patterns. This lighting effect is sound activated. Due to the high operating temperature of halogen lamps it is advisable that the effect be used in well ventilated areas taking care not to obstruct the air vents. After use allow time to cool for safety and to ensure lamp life before moving or touching. _ Installation / Mounting Although this unit can be used in an upright position, it is recommended that, for safety purposes, your lighting effect be properly mounted using a suitable hanging clamp and safety cable. CHAUVET offers a range of items, which are ideal for safe mounting. Use in a well-ventilated area without obstruction to air vents. Replacing Lamps 1. Disconnect from main power supply before attempting to replace either lamps or fuse. 2. Ensure that the unit is sufficiently cool, before removing blown lamps. 3. Never touch new lamps with your fingers: use a tissue or a cloth. In order to replace the lamp, disconnect from main power supply first, and unscrew the lamp replacement cover, which is highlighted on the diagram (fig.1).Only use the appropriately rated lamps as use of any other lamp type may cause the unit to be non-operational. Due to the nature of halogen lamps it is vitally important that you do not touch the new replacement lamp with your fingers, as this will reduce lamp life considerably. Once again a tissue or cloth can be used for fitting the replacement lamp. Finally before using, check that the lamp is housed correctly in the lamp holder and that the lamp replacement cover has been screwed back into place. If after replacement of the lamp, the unit is still not working then please contact CHAUVET for servicing. Replacing Fuses If the unit does not function at all when connected to the main power supply i.e. the mechanism does not Spin, then it is highly likely that the fuse has blown. Disconnect from main power supply before attempting to replace either lamps or fuse In order to replace the fuse, disconnect from the main power supply first, and unscrew the fuse holder cover to reveal the fuse. The unit has a label attached which indicates the correct fuse rating and you will also find this listed as part of the specifications for the unit later in this guide. It is most important that replacement fuses are of the correct rating. Failure to use the correct fuse could damage the lighting effect beyond economic repair. The fuse should simply be placed inside the holder and the screw cap replaced, when this is done connect to the main power s...