Log:
valutazioni - 5, GPA: 4.2 ( )

Istruzioni per l'uso Health O Meter, Modello PRO PLUS 2650KL

Produttore : Health O Meter
File Size : 1.41 mb
File Nome : 2650kl-manual.pdf
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


If the wheelchair weight is unknown, place the wheelchair only on the platform; press REWEIGH. Enter the Automatic TARE by pressing the TARE button. 4. Move the wheelchair and patient onto the platform over the ramp until the front wheelchair wheels are stopped by the platform guardrail. The display should read “WEIGHING“ until the weight of the patient is displayed. 5. We recommend reweighing after the patient is sitting still on the wheelchair on the platform by pressing the REWEIGH button. 6. Remove the wheelchair and patient from the scale by moving straight back off the ramp. NOTE: The scale will always default to the settings and units last used. 7 OPERATION INSTRUCTIONS Figure 6. Keypad ITEM DESCRIPTION FUNCTION POWER Turns scale ON and OFF. ZERO Zeros the scale prior to weighing. HOLD/RELEASE Holds the value of the weighed object on the display until the button is pressed again to clear the value. Also used to scroll down in the menu. REWEIGH Allows repeated weighing of the patient without stepping off the scale. KG/LB button Toggles between kilograms or pounds. Also used to scroll up in the menu. MENU Press 10 seconds in order to enter the scale menu. BMI Prompts entry of data to calculate the patient’s Body Mass Index (BMI). PRINT Prints patient’s data (if printer is connected to the scale). ID Prompts entry of patient’s identification number (ID). This ID will be stored with all the weighing made until is cleared or a different ID is stored. TARE Prompts entry of TARE value that will be deducted from the weight on the platform. Also releases tare weight (returns display to zero). EXIT Reverts back one step when in the menu and data entry modes. ENTER Used to enter commands and values into the scale. 8 OPERATION INSTRUCTIONS MENU In the menu screen the user can set preferences and/or instruct the scale how to handle stored data. The menu can be navigated using the up and down keys (....) or by entering the associated menu position number with the keypad. The menu has a “roll-over” way of working: when the user scrolls to the bottom of the menu and presses the down button, it will return to the top of the menu. Figure 7. Main Menu 01 WEIGHT DISPLAY MODE (only applies to pound values, NOT the metric values) The user can set the screen display value in either fraction of pound (., . or . lb), in pounds and ounces (resolution of 4 ounces) or in decimals (resolution of 0.2 lb). When kg is selected as the units of use, these settings have no effect. The mode that is selected is used through all the screens. Figure 8. Weight Display Mode 9 OPERATION INSTRUCTIONS 02 TARE WEIGHT NOTE: Due to the scale’s sensitivity, we recommend using the REWEIGH function prior to setting the TARE weight, in order to eliminate any operator interference with the item to be tared out. There are two ways to manually enter a tare weight (such as the weight of a wheelchair, shoes, etc): press MENU (1) and select option 02-Tare Weight or press TARE (9). If there is no weight on the scale platform (value displayed is zero and there is no tare) and the user presses the TARE button (9), the Tare Weight window appears and prompts the user to enter the TARE value and to press ENTER. NOTE: The tare weight must be entered using the following increments: 4oz, 0.2lb, .lb. The value entered will display in minus (-). After the TARE has been entered, the scale goes back to normal operation. This TARE value is stored in memory until changed or cleared. Important: The TARE weight cannot exceed 200 lb. The number that is to be changed will flash and will move from the left to the right after the appropriate number was entered or by using the .. key (left) and the .. key (right). TARE display indicates the weight that has been tared out Figure 9. Tare Weight Automatic Tare The user can set a tare weight by pressing the TARE button (9) while there is a weight on the scale platform. The display will come to zero and TARE will be displayed to indicate there is a tare value in the memory (as displayed in Figure 9 above). Removing the Tare Additional pressing of the TARE button will delete the tare value from memory, TARE will disappear from the display and the scale will resume normal operation. 03 DATA MANAGEMENT The scale manages patient data including patient ID, weight, height, tare and BMI. The value is stored in memory or transferred to PC. This function is performed by opening a new data file. OPENING A NEW DATA FILE: 1. Press the ID button (7). 2. Using the keypad, type in the identification number. 3. Press ENTER. This scale will also calculate Body Mass Index (BMI). CALCULATING BMI: 1. Place the patient on the scale platform. 2. Press the BMI button (2). 10 OPERATION INSTRUCTIONS 3. The scale will prompt you to enter the patient’s height. Use the keypad to enter the height in 1/4" (1=1/4, 2=1/2, 3=3/4) or 1 cm increments (use inches for weight in lb, cm for kg). Press ENTER. 4. Display will read the patient’s BMI. The scale offers you tw...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie