|
Istruzioni per l'uso Lifescan, Modello OneTouch Ultra
Produttore : Lifescan File Size : 2.31 mb File Nome : bacc5817-77c1-444c-8da1-34ba0f8f55cc.pdf
Lingua di insegnamento:
|
|
|
|
Vai a scaricare
Facilità d'uso
Test strip inserted incorrectly or Insert the test strip correctly incompletely with the contact bars end first and facing up. Push it in until it will go no further. Defective meter or test strip Call 1 800 663-5521. If the test does not start after applying the sample: POSSIBLE CAUSE WHAT TO DO Insufficient blood sample Repeat the test with a new test strip and a larger sample. Defective test strip Repeat the test with a new test strip. Sample applied after automatic Repeat the test with a new test shutoff (two minutes after last strip; apply sample only when user action) R appears on the display. Defective meter Call 1 800 663-5521. 57 SPECIFICATIONS Result Range: 1.1 to 33.3 mmol/L (20 to 600 mg/dL) Calibration: Plasma-equivalent Sample: Fresh capillary whole blood Sample Size: Minimum 1 microlitre Test Time: 5 seconds Assay Method: Glucose oxidase biosensor Power Source: One replaceable 3.0 V (#2032 or equivalent) lithium battery Battery Life: 1,000 tests or about one year at three tests per day Glucose Units: mmol/L Memory: 150 blood glucose and control solution tests Automatic Shutoff: Size: Two minutes after last user action 7.9 cm x 5.7 cm x 1.9 cm Approximate Weight: 42.5 grams with battery Operating Ranges: Temperature 6–44°C/43–111°F Relative Humidity 10–90% Hematocrit 30–55% 58 GUARANTEE The makers guarantee that the OneTouch® Ultra® Meter shall be free of defects in material and workmanship for a period of three years. This guarantee is valid from the date of purchase. The guarantee extends only to the original purchaser and is not transferable. The OneTouch® Ultra® Blood Glucose Meter complies with the following standards: CAN/CSA C 22.2 No. 601.1 – M90 “Medical Electrical Equipment – Part 1: General Requirements for Safety” (Complies with UL 2601-1) EN 60601-1-2 (1993) “Medical electrical equipment: Part 1, Section 1.2 Collateral standard:” EMC requirements & tests.” EN 50082-1 (1998) “Electromagnetic Compatibility, Generic Immunity Standard, Part 1, Residential, Commercial & Light Industry.” - Internally powered equipment. - No patient-applied parts. -This unit is not suitable for use in the presence of a flammable anesthetic mixture with air, oxygen, or nitrous oxide. 59 INDEX Averages, 14- and 30-Day. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Blood Sampling, Forearm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Blood Sampling, Fingertip . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 C Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Checking the Meter Display. . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Checking the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Coding the Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Control Solution, Checking with …. . . . . . . . . . . . . . . . . . . . . . 15 Control Solution, OneTouch® Ultra®. . . . . . . . . . . . . . . . . . . . . 15 Control Solution Results, Comparing . . . . . . . . . . . . . . . . . . . 20 Control Solution Test Information, Important . . . . . . . . . . . . . 16 Data Downloading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Data Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Display Messages/Problem-Solving Guide. . . . . . . . . . . . . . . 48 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Laboratory Results, Comparing Meter Results with … . . . . . . 38 Lancet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Lancet Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 LifeScan Interface Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 M Button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Memory, Using . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Messages, Special . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 60 Meter Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Meter Display, Checking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Meter Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Meter Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 OneTouch™Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 OneTouch®Ultra®Blood Glucose Meter . . . . . . . . . . . . . . . . . . 6 OneTouch® Ultra® Blood Glucose Monitoring System . . . . . . . 5 OneTouch®Ultra®Control Solution . . . . . . . . . . . . . . . . . . . . . 15 OneTouch®Ultra®Test Strips . . . . . . . . . . . . . . . . . . . . . . . . . . 10 - Code. . . . . . . . . . . . . . . . ...
Scrivi la tua opinione del dispositivo
|
|