Log:
valutazioni - 3, GPA: 4 ( )

Istruzioni per l'uso Cleveland Range, Modello ConvectionPro Steamers 36CSM16

Produttore : Cleveland Range
File Size : 2.63 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Allows unit to start cooking instantly. ■ Durable 10 Gauge Stainless Steel Construction: For Compartment Door and Steam Cooking Cavity. ■ Separate Main Power Switch for “On/Off’ ■ Unique Patented Steam Cooking Distribution System: The patented Convection Jets produce a high velocity convection steam without fans. Coved Comer design in cooking compartment distributes heat evenly and is easy to keep clean. Creased bottom enhances drainage. Cold Water Condenser for each compartment maintains a dry steam. Fully insulated cooking compartment for thermal efficiency. Removable Stainless Steel Slide Racks for easy cleaning. ■ Heavy duty, one piece, solid compartment door design with replaceable door gasket. ■ Left Hand Door Hinging: Compartment Doors hinged left, controls on the right. ■ Modular Cabinet Base with Hinged Door. ■ Heavy duty Stainless Steel Base Frame. ■ Electric Steam Generator: Automatic Water Fill on start up. ■ Automatic Generator Drain at shutdown: Large %" drain valve contains a “Water Jet” Spray Rinse Cleaning Cycle to keep drain clear. ■ Automatic Water Level Control System with Low Water Power Cut-off Circuit. ■ Steam generator equipped with High Limit Pressure Safety Switch, 15 psi Safety Valve, and Steam Generator Pressure Gauge. ■ NSF Approved 6" Stainless Steel Adjustable Legs: Provides one inch level adjustment. ■ Standard voltage 208 or 240 volts, 60 Hz, 3 phase. ■ All Controls are serviceable from the front. ■ Compartment Door Steam Shut Off Switch. MODEL: □ 36-CEM-16-48 ITEM NUMBER JOB NAME / NUMBER Shown with optional Electronic Timer MODEL AVAILABLE Model No. Description 36-CEM-16-48 ConvectionPro XVL- Two Large Compartments, cabinet mounted; Convection; 48 KW Electric Steam Generator, 36" Wide Cabinet Base. Options and Accessories: □ Electronic Timer with Compensating Load Feature. (ETC) □ ON/OFF Steam Switch only for compartment controls (MC) □ Cafeteria pans in depths of 1", 2JT, 4" and 6" □ 12" x 18" Bun Pans □ Voltages other than standard □ Automatic Generator Mineral Purging Cycle (MPC) automatically cleans generator, reducing scale build up □ Correctional Packages □ 8", 10", Stainless Steel Adjustable Legs (LF-) □ Adjustable Flanged Feet (FF-A) □ Secondary Low Water Cut-Off, factory installed (CAL-E) (Required for AZ, CA, CO, CT, FL, GA, IL, IA, MA, MN, NE, NV, Rl, SD, TN, WA, Houston, TX.) SECT. PAGE 25 1094 Cleveland Range, Inc. 1333 East 179th Street Cleveland, Ohio 44110 Toll Free 1-800-338-2204 Phone (216) 481-4900 Fax (216) 481-3782 SHORT FORM SPECIFICATION Shall be Two Compartments, CLEVELAND Convection Steamer, Electric Steam Generator, Model 36-CEM-16-48, 48 KW Electric;_volts,_Hz,_phase, 3 wire. Solid State Controls operate timing, water level and safety functions. Type 304 Stainless Steel exterior paneling and cooking compartments. Insulated compartments. One, Solid State 99 minute digital Timer with Touch Control, per compartment Audible and Visual Signals for cycle completion and steam shut-off. •Each compartment has capacity for Eight, 12" x 20" x 2Vz” Cafeteria Pans. Can accommodate 18" x 26" Bun Pans. •Many local codes exist and it is the responsibility of the Owner and Installer to comply with those codes. •Cleveland Range equipment is built to comply with applicable standards for manufacturers, included among those approval agencies are: UL, A.G.A., NSF, % ASME/N.Bd., CSA, CGA, ETL, and others. WATER QUALITY REQUIREMENT The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows: TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 75 Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator. ELECTRIC® CLEARANCE 3 PHASE - 48 KW 208V AMPS PER LINE 119 127 220V 240V 116 480V 58 For power supply, use copper wire only. 35 psi minimum 60 psi maximum IPS cold water Vh” IPS common drain. Do not connect any other units to this drain. Floor Drain must be located outside the confines of the equipment base. Drain line must be vented. RIGHT = 12.00" if adjoining wall or equipment is over 30.00" high. LEFT = 0" REAR = 0- C»—»land Range гмегую right of design impro—mant or modification, as warranted. !-1 SCALE .50* = 1 ' SECT. Ш PAGE 26 1094 Utho in U.S-A. Cleveland Steam Cooking Specialists Convection Steamers ConvectionPro XVI® TWO LARGE COMPARTMENTS-PRESSURELESS 300M BTU GAS FIRED STEAM GENERATOR 36” WIDE CABINET B...

Questo manuale è adatto anche per i modelli :
Forni elettrici - ConvectionPro Steamers 36CDM16 (2.63 mb)
Forni elettrici - ConvectionPro Steamers 36CGM16 (2.63 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie