|
Facilità d'uso
THESE UNITSARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY. Noncombustible clearances: 0" sides (0 mm) 0" rear (0 mm) 4" floor (102 mm) Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the flue. Adequate clearance for air openings into the combustion chamber is required. Do not place objects between the bottom of the unit and the counter top. There must be adequate clearance for removal of the front panel. All major parts except the burners are removable thru the front if the gas line is disconnected. Unit must have adequate clearances for servicing. (Sides = 0”, Rear = 0”, Floor = 4”). European Community Installation Instructions: “THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE UK, CORGI REGISTERED INSTALLERS (INCLUDING THE REGIONS OF BRITISH GAS) UNDERTAKE TO WORK TO SAFE AND SATISFACTORY STANDARDS. THISAPPLIANCE MUST BE INSTALLED INACCORDANCE WITH THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELEVANT BUILDING REGULATIONS / I EE. REGULATIONS. DETAILED RECOMMENDATIONS ARE CONTAINED IN THE FOLLOWING BRITISH STANDARD CODES OF PRACTICE -BS 6172, BS 5440 PART 2, BS 6891" "THISAPPLIANCE MUST BE INSTALLED INACCORDANCE WITH THE RULES IN FORCE” "MUST BE INSTALLED INAWELLVENTILATEDAREA. Ventilation requirements ie. B.S. 5440." SPECIFICATIONS AND DIMENSIONS MODEL WIDTH IN. (MM) DEPTH IN. (MM) HEIGHT IN. (MM) #OF BURNERS BTU/kW PER BURNER NATURAL GAS TOTAL BTU/kW HOUR W.C. IN. (’Mbar ) GCB-18H 18 (457) 25.14 (639) 15.61 (396) 1 60,000/17.5 60,000/17.5 6/10(15/25) GCB-24H 24 (610) 25.14 (639) 15.60 (396) 2 40,000/11.7 80,000/23.5 6/10(15/25) GCB-36H 36 (914) 25.14 (639) 15.54 (396) 3 40,000/11.7 120,000/35 6/10(15/25) GCB-48H 48 (1219) 25.14 (639) 15.60 (396) 4 40,000/11.7 160,000/46.8 6/10(15/25) GCRB-18H 18 (457) 25.14 (639) 15.61 (396) 1 60,000/17.5 60,000/17.5 6/10(15/25) GCRB-24H 24 (610) 25.14 (639) 15.60 (396) 2 40,000/11.7 80,000/23.5 6/10(15/25) GCRB-36H 36 (914) 25.14 (639) 15.54 (396) 3 40,000/11.7 120,000/35 6/10(15/25) GCRB-48H 48 (1219) 25.14 (639) 15.60 (396) 4 40,000/11.7 160,000/46.8 6/10(15/25) 4 DIMENSIONS: GCB-18H & GCRB-18H DIMENSIONS: GCB-24H & GCRB-24H 15.61 15.00 18.00 18.57 4.00 25.14 4.95 9.00 30.39 30.08 4.95 8.64 18.57 25.14 3.68 15.60 21.00 24.00 5 (772) (126) (229) (396) (381) (457) (472) (639) (102) (126) (219) (396) (533) (610) (93) (472) (639) (764) 4.95 9.55 25.05 33.00 36.00 15.54 18.57 25.14 4.95 10.61 45.00 48.00 15.60 18.57 25.14 3.69 DIMENSIONS: GCB-36H & GCRB-36H DIMENSIONS: GCB-48H & GCRB-48H 6 (126) (243) (636) (838) (914) (396) (472) (639) (126) (269) (396) (1143) (1219) (472) (639) (94) CONVERSION . Instructions are for conversion from Natural Gas to Propane (L.P.) on all models GCRB and GCB. . The conversion should be done before connecting the unit to the gas supply. . Units are shipped from the factory equipped for use on natural gas. Orifices necessary for LP (propane) are provided in a bag tied to the valve on the front panel. 1. Remove the knobs and front panel. 2. Remove the orifice fittings from the valve. Change the orifices to the size recommended for propane (L.P.). 3. Replace the orifice fittings into the valve. 4. Remove cap, invert the insert and replace cap. NOTE: Marking on insert. 5. Continue with the installation. LIGHTING INSTRUCTIONS GCB and GCRB Broilers are furnished with either a pilot safety valve or a standing pilot (not available in the European Community). Please follow the instructions for your unit. Pilot Safety Valve Lighting Instructions: Lighting instructions are on the right side panel. If the pilot goes out, an automatic shutoff valve turns off the gas supply to the burners. To relight the pilot, follow this procedure: . Turn the control valve to "OFF". Wait a sufficient length of time to allow gas, which may have accumulated in the burner compartment, to escape (at least five minutes). . Turn on the main shutoff valve. . Depress and hold in the red button "A" on the automatic shutoff valve while lighting the pilot burner. . When gas at pilot has been burning for about 45 seconds, release the red button. If pilot does not remain lit, repeat the operation, allowing more time before releasing red reset button. The button can be accessed through an opening in the front panel. . To adjust the pilot flame, Rotate the knob clockwise to reduce the gas flow, and counterclockwise to increase the gas flow; to provide a properly sized pilot flame (approximately 1/2" to 3/4" long). (12 to 19 mm) . All units are equipped with fixed orifices for use with natural gas, and no adjustment is necessary. . Units for operation on natural or propane gas, are also equipped with a factory preset pressure regulator with an outlet pressure of 6.0" W.C. (15 'mbar') for natural gas supply, and 10" W.C. (25 'mbar') for propane gas supply, and should not require further adju...
Questo manuale è adatto anche per i modelli :Forni elettrici - GCRB-18H (2.31 mb)
Forni elettrici - GCB-18H (2.31 mb)
Forni elettrici - GCB-24H (2.31 mb)
Forni elettrici - GCB-36H (2.31 mb)