Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso Bodyline Products International, Modello AXIS AIR SHAVER AX-5330

Produttore : Bodyline Products International
File Size : 1.97 mb
File Nome : 20b14c68-7868-41c8-ac95-84886d31cd4f.pdf
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


After every use with soap or shaving foam, be sure to wash away the residues with water. FINE mode This mode is provided for shaving your upper and lower lips 1. ) Slide up the FINE mode switch to “FINE”. The outer foil for FINE mode will be pushed up. 2. Gently bring the outer foil in contact with your upper or lower lip, and shave slowly while stretching the skin to make your beard stand up. CARE AND MAINTENANCE Before cleaning the shaver, be sure that the AC adaptor is discon- Flex-FoilTM hood Flex-FoilTM hood release button release button nected from the shaver. Washing in water 1. Slide the power switch off, and press the outer foil frame release buttons on the sides at the same time to remove the outer foil frame. 2. Slide the power switch on, and wash the blades in cold or lukewarm water. After washing, slide the power switch off, and wipe them dry with a towel or cloth. 3. Place the shaver in an open-air resting place to dry it correct incorrect Rear Rizer TM thoroughly. 4. Attach the outer foil frame securely to the body case, and be very careful not to touch the outer foil. It is recommended that inner blade be cleaned with the brush at least once every three (3) washings. Cleaning with the brush 1. Before cleaning your shaver, be sure to slide the power switch off, and press both the outer foil frame release buttons on the side at the same time to remove the outer foil frame. 2. Push the two outer foil unit release knobs inside the outer foil frame from both sides with fingers, and remove the outer foil unit. 3. You can clean the inside of the outer foil, the inside of the outer foil unit, the inner blade and the body of the shaver with the accessory Axis Air |2 | english brush. * To remove the inner blade, pull it straight upwards. * Do not touch the sharp edges of the blade portion of the inner blade. * Do not press hard against the inner blade. Doing so may deform or damage it, which typically produces a poor shave and an unusual noise. 4. After cleaning, attach the outer foil unit securely to outer foil frame. Make sure you do not touch the outer foil. 5. Then, attach the inner blade to the vibrator. Set the outer foil frame securely to the body, and check that it is well secured on the body. If the outer foil for FINE mode is in a pushed-up position, push its both ends lightly to reset it in position, and then, reinstall the outer foil frame. If the shaver is used with the outer foil frame incorrectly set to the Axis Air |2 | english body, this will typically produce a poor shave and unusual sound. Do not remove the outer foil from the outer foil unit. 6. Before cleaning the trimming blade, slide the power switch off. Check that the trimming blade is not moving when cleaning it. Notes: After cleaning the shaver, apply shaver oil (sold separately) to Flex-FoilTM hood screw rear panel side panel screw inner cut- Ni-Mh battery inner case shaver backAB Axis Air |2 | english the outer foil surface once every 3 uses. When the shaver has not used for a long time, be sure to clean the outer foil, inner blade and trimming blade, and apply shaver oil to the outer foil surface. FOR RECYCLING THE Ni-Mh BATTERY Never disassemble the shaver to remove the Ni-Mh battery except to dispose of the shaver. The Ni-Mh battery in your shaver is recyclable. When you dispose of the shaver, please take care to remove the Ni-Mh battery and recycle it. How to remove the Ni-Mh battery > Turn on the power switch, and run the battery down until the inner blade stops moving. If the shaver is disassembled before the recharged electricity is depleted, it may cause a shock, catch fire and cause burns. Axis Air |2 | english > Follow the procedure below to disassemble the shaver with a screwdriver. 1. Remove the outer foil frame, outer foil frame and inner blade. 2. Loosen and remove the 4 screws on the top and bottom of the body with a Phillips screwdriver. (See the illustration “A”.) 3. Remove the side and rear panels. (See the illustration “A”.) 4. Loosen and remove the 6 screws with a Phillips screwdriver, and remove the rear case. (See the illustration “B”.) 5. Cut the lead wires, and take out the Ni-Mh battery from the inner case, while taking care not to short-circuit the (+) and (–) terminals. (See the illustration “B”.) SPECIFICATIONS > Power supply: Rechargeable battery/AC power supply Axis Air |30| english > Blade motion: > Inner blade: Reciprocating > Trimming blade: Reciprocating > Rated voltage: AC 100 V – 240V > Rated frequency: 50/60 Hz > Rated current: 200 mA > Rated time: 5 minutes > Standard recharging time: 1 hour > Battery: Ni-Mh cell (enclosed type), 2 pcs. > Battery voltage: 1.2 V x 2 > Weight: 202 g Axis Air |31| english > Operating temperature range: 0° C – 40° C * The above specifications are subject to change without prior notice for product improvement. ACCESSORY PARTS (SOLD SEPARATELY) > It is recommended that the outer foil and inner blade be replaced at the same time approximately every 1 and 2 ye...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie