Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Carrier, Modello HOME STANDBY ASPBS1CCA016

Produttore : Carrier
File Size : 384.14 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Aluminum w/Cast Iron Sleeve Valve Arrangement.............................................................................................. ................................................. Overhead Valve Ignition System.................................................................................................... ............................................ Solid-state w/Magneto Governor System................................................................................................. ...................................................... Electronic Compression Ratio.............................................................................................. .......................................................... 9.5:1 Starter.................................................................................................................. ........................................................ 12Vdc Oil Capacity Including Filter................................................................................. ............................................... Approx. 1.7 Qts. Standby Operating RPM...................................................................................... ....................................................... 3,600 Exercise RPM..................................................................................................... ....................................................... 2400 Fuel Consumption Natural Gas cu.ft./hr ........................................1/2 Load 173 ........................................Full Load 245 Liquid Propane ft3/hr (gal/hr) ........................................1/2 Load 59 (1.59) ........................................Full Load 92 (2.51) Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas CONTROLS Mode Switch -Auto................................................................................................................ .............................. Automatic Start on Utility failure 7 day exerciser -Off.................................................................................................................. ........................ Stops unit. Power is removed Control and charger still operate -Manual/Test (start)......................................................................................... ............................ Start with starter control, unit stays on. If utility fails, transfer to load takes place. Engine Start Sequence Cyclic cranking: 7 sec. on, 7 rest (90 sec. maximum duration) Engine Warm-up................................................................................................. ................................................... 10 seconds Engine Cool-Down.............................................................................................. ...................................................... 1 minute Starter Lock-out.................................................................................................. ..................................... Starter cannot re-engage until 5 sec. after engine has stopped. 2.5 Amp Timed Trickle Battery Charger............................................................ .................................................... Standard Automatic Voltage Regulator w/Overvoltage Protection..................................... ...................................................... Standard Automatic Low Oil Pressure Shutdown.............................................................. ...................................................... Standard Overspeed Shutdown......................................................................................... ..................................................Standard, 72Hz High Temperature Shutdown.............................................................................. ...................................................... Standard Overcrank Protection.......................................................................................... ...................................................... Standard Safety Fuse......................................................................................................... ..................................................... Standard Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability Is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F). Home Standby - 16kW (...

Questo manuale è adatto anche per i modelli :
Energia elettrica - HOME STANDBY ASPBA1CCA016 (384.14 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie