Models RGH3000 and RGH3000PR have only the 120V, 15-amp GFCI duplex receptacle. 120V, 15-Amp GFCI Duplex RESET 240 VOLTSRESET RESET RESET RESETTEST 120 VOLTS RESET RESET ENM00000005HOURS 1/10 120ONLY 120240V 120/240V, 20 or 30- Amp Twist-Lock 120V, 30-Amp Twist-Lock 120V, 15-Amp Duplex 120/240V, 50-Amp (Model RGH11000IE only) Figure 15 - Receptacle Locations POWER CORD AND PLUG REQUIREMENTS 120V, 30-amp twist-lock receptacle • NEMA L5-30P plug • Three-wire, 30-amp cord 120/240V, 20 or 30-amp twist-lock receptacle • NEMA L14-20P (20-amp) or L14-30P (30-amp) plug • Four-wire, 20-amp or 30-amp cord 120/240V, 50-amp receptacle • NEMA L14-50P • Four-wire, 50-amp cord 120/240 Volt 20 Amp w G Y XX (Hot) 120V 120V Neutral L14-20P Plug Ground (Green) Ground W Y (Neutral) (Hot) Neutral L14-20P 20 and 30 120/240 Volt Plug Amp w G Y X w G Y X 120V 120V Neutral Ground X (Hot) W (Neutral) 120V 120V Ground L14-50P Ground (Green) w GY X Plug 120V 120V Neutral L14-30P Y Plug (Hot) Ground Figure 16 - Cord and Plug Configurations Continued 104960 11 ® ® PORTABLE GASOLINE GENERATORS OPERATION Continued PRESTART Operate generator on a firm, dry, and clean surface. The surface must be level. Protect generator from heavy dust, sand, dirt, rain, or snow. Do not locate generator near standing water and snow. Make sure area is well- vented. WARNING: Only responsible adults should use generator. Never let anyone operate generator without proper instructions. Note:If oil level is too low, oil alert system will keep engine from starting (see Oil Alert System, page 6). Make sure oil level is full before starting. See Engine Oil, page 7. Before starting the engine, disconnect all electric loads from generator. STARTING IMPORTANT:The engine speed is preset. The throttle is locked in preset position. Do not adjust throttle. Preset position lets engine run at 3600 RPM under load. The engine must maintain 3600 RPM for generator to create correct voltage. Running engine at lower speeds will damage generator and powered items. IMPORTANT:Never start generator with electrical loads connected. Start engine before adding electrical loads. 1. Make sure gasoline tank is full. See Fuel, page 7 for fuel information. 2. Move fuel valve lever to the ON position (see Figure 17). 3. Move choke lever fully to the left (see Figure 17) or pull choke button out (Model RGH11000IE only, see Figure 18). This closes the choke. Note:You may not need to close choke if engine is warm or air temperature is high. 4. Start the engine. A. Recoil Starter Turn engine switch to the ON position (see Figures 19 and 20). Remove slack from starter rope by lightly pulling starter grip. Next, pull starter rope briskly. IMPORTANT:Do not let starter grip snap back against engine. Return it gen tly. This will prevent damage to starter. Note: If engine does not start, check the oil in the crankcase. Add oil as necessary. Be sure engine is on a level surface. See Oil Alert System, page 6. B. Electric Starter (Models RGH5500IE, RGH7500IE, and RGH11000IE Only) Turn the engine switch to the START position (see Figure 20). Hold it there until engine starts. When engine starts, let switch return to the ON position. IMPORTANT: Do not use electric starter more than five seconds. Starter motor damage may occur. If engine fails to start, release the switch and wait ten seconds. After ten seconds, try starting again. Note: If engine does not start, check the oil in the crankcase. Add oil as necessary. Be sure engine is on a level surface. See Oil Alert System, page 6. 5. As engine warms up, slowly move choke lever fully to the right (see Figure 21). This opens the choke. On Model RGH11000IE, the choke will automatically open. Choke Lever (Closed Position) Fuel Valve Lever (ON Position) Figure 17 - Fuel Valve Lever On, Choke Lever Closed (Model RGH5500 Shown) Choke Button Pulled Out (Closed Position) Figure 18 - Choke Button Closed (Model RGH11000IE Only) ENGINE SWON OFF Figure 19 - Engine Switch In ON Position (All Models Except RGH3000PR, RGH5500IE, RGH7500IE, and RGH11000IE) Engine Switch HONDA OFF ON START ENGINE SW CIRCUIT BREAKER ON/push OFF Figure 20 - Engine Switch (Models RGH5500IE, RGH7500IE, and RGH11000IE Only) Choke Lever (Open Position) Figure 21 - Choke Lever Opened (Model RGH7500IE Shown) 12 104960 OWNER’S MANUAL OPERATION Continued HIGH ALTITUDE OPERATION This generator will not perform well at high altitudes without proper adjustment. See engine owner’s manual for details. ADDING ELECTRICAL LOADS IMPORTANT:Do not overload generator. Make sure total wattage of all electrical loads does not exceed rated wattage of generator. Overloading may shorten generator life. It could also cause internal damage to generator. Overloading will trip circuit breaker. IMPORTANT: (All models except RGH3000, RGH3000PR, RGH7500IE, and RGH11000IE) Keep full power selector switch in the 120 VOLT ONLY position if only powering 120V items. Only move switch to 120/240 VOLT position if powering 240V item...
Questo manuale è adatto anche per i modelli :Energia elettrica - Rgh3000, Rgh3000pr, Rgh5500, Rgh5500ie, Rgh7500ie, Rgh11000ie (887.44 kb)