Log:
Scaricare : 0   File Size : 10 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica
@name

3 GENERAL INFORMATION Section 1 - General Information QUIETPACT™ 75D Recreational Vehicle Generator 1.1 GENERATOR IDENTIFICATION Please record the following information from the generator DATA DECAL or information decal, located below the user control panel. 1. Model Number ___2. Serial Number __ 3. kW Rating. Rated Voltage 15 12 3 22 FRONT VIEW 21 ,16 Model: 04270-0 QUIETPACT™ 75D 1. 2-Pole, 35-amp Circuit Breaker 2. Hourmeter 3. Oil Fill Opening and Plug 4. Oil Dipstick 5.

Scaricare : 0   File Size : 8 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica
@name

IF YOU FEEL ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET MEDICAL HELP. Do not operate the generator until its exhaust system has been inspected and properly repaired. -A CAUTION A- A Never tee the generator engine exhaust pipe into the vehicle engine exhaust piping. This causes excessive back pressure on the generator engine. Also, water from one engine can damage the other engine. ♦ 6.6.1 MUFFLERS AND SPARK ARRESTORS This muffler meets code and standard r

Scaricare : 2   File Size : 7 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica

Scaricare : 7   File Size : 6 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica
@name

SCREW HHC M10-1.0 X 25 G10.9 86 022985 3 WASHER FLAT #6 ZINC 42 046526 18 WASHER LOCK M10 87 036261 3 RIVET POP .125 X .275 SS 43 022131 11 WASHER FLAT 3/8-M10 ZINC 44 059982 4 SCREW SHC M12-1.75 X 45 G10.9 * NOT SHOWN-USED TO HOLD OIL DRAIN ASSEMBLY. 45 098780 2 SCREW HHC M12-1.75 X 65 G8.8 ** NOT SHOWN 46 051769 3 WASHER LOCK M12 Generac® Power Systems, Inc. 35 ENGINE 5 "A" 12 FRAME 10 9 11 8 9 3 27 21 PUMP TO WATER 4 12 17 6 15 7 1 15 20 3 22 24 24 TO 2 12 TO "A" 18 13 14 12 Section 7 - Explo

Scaricare : 0   File Size : 6 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica
@name

ELECTRICAL HAZARDS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as well as the standby generator. Avoid contact with bare wires, terminals, connections, etc., on the generator as well as the transfer switch, if applicable. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If work must be done aroun

Scaricare : 1   File Size : 6 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica

Scaricare : 0   File Size : 6 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica
@name

Control system interconnection leads must be run in a conduit that is separate from the AC power lead. Recommended wire gauge sizes for this wiring depends on the length of the wire, as recommended below: MAXIMUM WIRE LENGTH RECOMMENDED WIRE SIZE 460 feet (140m) No. 18 AWG. 461 to 730 feet (223m) No. 16 AWG. 731 to 1,160 feet (354m) No. 14 AWG. 1,161 to 1,850 feet (565m) No. 12 AWG. • 2.9.2 GTS-TYPE ATS If the generator is to be installed with an automatic transfer switch, such as an engineered

Scaricare : 1   File Size : 5 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica
@name

If, however, adjustments are necessary, or a new engine control board is installed in the generator, the following procedure should be followed (Figure 3.2): 1. Set all three potentiometers (pots) fully counterclockwise. 2. Under no load condition, increase the GAIN pot as much as possible without causeing instability. 3. Apply 1/4, 1/2, 3/4 and full load to the unit. Decrease the GAIN pot if there is instability at any load point. 4. Under full load condition, increase the stability pot until t

Scaricare : 0   File Size : 5 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica
@name

After the generator starts, the transfer switch transfers load circuits so the generator can power them. When utility source voltage has been restored, the switch re-transfers back to the utility source voltage and the generator then shuts down. Please reference the transfer switch manual for specific information. 1.4 GENERATOR AC CONNECTION SYSTEMS The generator was shipped from the factory with its stator AC output leads connected in a single-phase, 3-wire generator AC connection system (Figur

Scaricare : 3   File Size : 5 mb   Produttore : Generac Power Systems  
Categoria : Energia elettrica
@name

005040-0, 005040-1 (25kW) 005053-0, 005053-1 (20kW) 005054-0, 005054-1 (15kW) This manual should remain with the unit. ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION!! INTRODUCTION Thank you for purchasing this model of the Guardian Elite standby generator series by Generac Power Systems, Inc.. Every effort was expended to make sure that the information and instructions in this manual are both accurate and current at the time the manual was written. However, the manufactu





categorie