|
Facilità d'uso
11. DO NOT use outdoors. 12. To prevent a possible fire, DO NOT block air intakes or exhaust in any manner. DO NOT use on soft surfaces, like a bed, where openings may become blocked. 13. To disconnect heater, set controls to OFF, then remove plug from outlet. 14. Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord shall be No. 14 AWG minimum size and rated not less than 1875 watts. 15. Always unplug the heater when not in use. PLEASE SAVE THESE INSTRUCTIONS. CONSUMER SAFETY INFORMATION THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC (Alternating Current) PLUG (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the proper outlet. DO NOT DEFEAT THE SAFETY PURPOSE OF THIS POLARIZED PLUG IN ANY WAY. The length of the cord used on this product was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the heater. Care must be taken to arrange the extension cord where it cannot be pulled on by children or accidentally tripped over. AUTO SHUT-OFF To prevent damage and risks due to overheating this unit is equipped with a built-in overheat protection device. It cuts off the power as soon as the heater’s internal temperature becomes too high. This patented, technologically advanced system requires the user to reset the heater in case of a potential overheat situation. It will only resume operation when the user resets it. To Reset the Heater: 1. Unplug the heater and wait 10 minutes for the unit to cool down. 2. After the 10 minutes, plug the unit in and operate normally. PRE-OPERATING INSTRUCTIONS Carefully unpack your heater from the box (it is recommended to save the box for off-season storage). OPERATING INSTRUCTIONS 1. Place the unit on a firm level surface. Plug in the heater to a 120V power source. 2. To start the unit, press the Power button (BCH3220) or turn the mode knob (BCH3210) located on the control panel. The power light will remain lit while the heater is in operation. For BCH3210, make sure that the mode knob is in the OFF position. THERMOSTAT INSTRUCTIONS On the first use, the heater will operate in fan mode. After initial use, the heater will operate on the last programmed setting. This function allows you to set the heater to your desired comfort level. The heater will maintain your desired room temperature. For BCH3210: 1. Set the THERMOSTAT knob to the highest setting, clockwise as far as it will turn. 2. When the desired room temperature level is reached, lower the thermostat setting, by turning the THERMOSTAT knob counter clockwise as far as it will turn. 3. The thermostat will now automatically maintain the pre-set temperature level by turning the heater on and off. The thermostat is now set. Figure 1 High Current Room Temperature Indicator Set Temperature ff Higher Power Lower Button Set Mode Temperature Night Light Button Indicator Button BCH3220 BCH3210 For BCH3220: 1. To change the heater settings, press the MODE button. Each time you press the MODE button, it will scroll through the settings FAN, LOW, HIGH, AUTO. Note: The fan speed will not change when the mode is changed from low to high. 2. Select the AUTO mode. 3. Set the heater to the desired room temperature by pressing the (+) or (-) buttons. Note that the degree range is from 60°F - 85°F (15°C - 29°C). If you scroll past 85°F (29°C) the display will automatically loop to 60°F (15°C). 4. Now the desired temperature is set. Note: When the temperature in the proximity of the heater reaches the set temperature, the heater will automatically turn on. The fan will continue to run cooling the heater for 30 seconds. The unit will operate again when the temperature falls below the preset temperature. mode thermostat Fan Low Mode HIGH LOW FAN AUTO ROOM TEMP. SET TEMP. Light Sensor . TIP: It is normal for the heater to cycle ON and OFF as it maintains the preset temperature. To prevent the unit from cycling, raise the thermostat setting. 90° SWIVEL INSTRUCTIONS For maximum heat distribution use the revolutionary vertical twin housing configuration to allow heat to travel in two different directions. 1. Carefully adjust each swivel to direct the heat flow. 2. Do not swivel the unit beyond the point of resistance. NIGHTLIGHT (BCH3220 only) 1. The nightlight will automatically light when the room becomes dark. When the room becomes light, the nightlight will automatically turn off. 2. To turn the nightlight off, press the button on the control panel. . TIP: The nightlight will not automatically operate until the button is pressed again. MAINTENANCE INSTRUCTIONS During Seaso...
Questo manuale è adatto anche per i modelli :Elettrico - BCH3210 (6.57 mb)