|
Facilità d'uso
Air Inlet 2.5 ft. Top 6 ft. Air outlet 12 ft. • Floors and ceilings must be made of fireproof materials in the room where the heater is operated. • The air inlet and outlet must never be blocked for any reason. • Install the heater on a flat, level floor in a steady postion. • It is forbidden to connect direct-fired heaters to air ducts. warning • DO NOT USE GASOLINE, NAPHTHA OR VOLATILE FUELS. • STOP HEATER BEFORE ADDING FUELS. • ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME • DO NOT USE EXTERNAL FUEL SOURCE. • DO NOT OPERATE HEATER WHERE FLAMMABLE LIQUIDS oR VAPoRS MAY Be PReSeNT. • DO NOT START HEATER WHEN CHAMBER IS HOT • DO NOT START HEATER WHEN EXCESS FUEL HAS ACCUMUlATeD IN THe CHAMBeR. • DO NOT PLACE COOKING UTENSILS ON TOP OF THE HeATeR. • PLUG ELECTRICAL CORD INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. The heater can only work automatically when a control device, such as for example a thermostat or a timer, is connected to the heater. Connection to the heater is made by removing the socket cover(4) and inserting the thermostat plug. To start the machine you must: •If connected to the thermostat, turn the switch to (ON + ); •If not connected to the thermostat, turn the switch to (ON). When unit is started for the first time or is started after the oil tank has been totally emptied, the flow of oil to the burner may be impaired by air in the circuit. In this case the control box will cut out the heater and it might be necessary to renew the starting procedure once or twice by depressing the reset button (1). Should the heater not start, check that oil tank is full and depress reset button (1). Should the heater still not work, please refer to chapter “oBSeRVeD FAUlTS, CAUSeS AND ReMeDIeS”. stOpping tHe Heater Set main switch (3) on “0” position or turn thermostat or other control device on lowest setting. The flame goes out and the fan continues to work for approx. 90sec. cooling the combustion chamber. saFetY deVices The unit is fitted with an electronic flame control box. In case of malfunction this box will cut in and stop the heater, at the same time the pilot lamp in the control box reset button (1) will light up. Heaters are also equipped with an overheat thermostat safety cutout which will stop the heater in case of overheating. This thermostat will reset automatically but you will have to depress button (1) on control box before being able to restart the heater. transpOrt warning • Before making any attempt to restart heater find and eliminate reason of overheating. Before heater is moved it must be stopped and unplugged. Before moving the heater wait till it has totally cooled off and make sure oil tank cap is securely fixed. eNeRCo GRoUP, INC. |Indirect Fired Portable Heater 4 operating Instructions and owner’s Manual The hot air heaters with wheels must be wheeled. The suspended version which has no wheels must be transported with adequate machinery. Maintenance Preventive and regular maintenance will ensure a long trouble free life to your heater. warning • Never service heater while it is plugged in, operating or hot. Severe burns or electrical shock can occur. every 50 hours of operation: disassemble filter and wash with clean oil, remove upper body parts and clean inside and ventilator with compressed air, check correct attachment of H.T. connectors to the electrodes and check H.T. cables, remove burner assembly, clean and check electrode settings, adjust according to scheme “GAP oF eleCTRoDeS”. Flue connections diagram VentilatiOn 6 “ description a) Minimal 39” B) Minimal 39” c) The shortest d) The same or bigger than the smokes outlet diameter of heater e) Minimal 1m 1) Anti-wind device provided with the heater 2) Horizontal crossing with minimal upside angle pitch of 5° 3) Chimney 8” x 8” of minimal inside measure 4) Chimney anti-explosion flap door 5) external seating wall 6) Chimney ending H shape n.B. above recommendation indicative only. Have your installation checked by local authority. 54A32DC1BA62DC1B5E eNeRCo GRoUP, INC. |Indirect Fired Portable Heater 5 operating Instructions and owner’s Manual trOuBlesHOOting trOuBle Motor does not start, no ignition cause No electrical current Wrong setting of room thermostat or other control Thermostat or other control defective electrical motor defective electrical motor bearings defective Burned out condenser sOlutiOn Check mains (should be 120 V – 1~ – 60 Hz) Check proper positioning and functioning of switch Check fuse Check correct setting of heater control. If thermostat, make sure selected temperature is higher than room temperature Replace control device Replace electrical motor Replace electrical motor bearings Replace condenser Motor starts, no ignition or cuts out electric ignitor defective Flame control box defective Photocell defective Not enough or no fuel at all at burner Solenoid defective Check connection of H.V. Ieads to electrodes and transformer Check electrodes setting (see scheme “GAP oF eleCTRoDeS”) Check electro...
Questo manuale è adatto anche per i modelli :Elettrico - HEATSTAR 1000ID (2.68 mb)
Elettrico - HEATSTAR 3000ID (2.68 mb)
Elettrico - HEATSTAR 4000ID (2.68 mb)