Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Cadet, Modello SOFTHEAT EBHN750

Produttore : Cadet
File Size : 209.41 kb
File Nome :

Lingua di insegnamento: enes

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Standard units are wired from left end of the heater only. (See Figure 5 for internal heater wiring). When wiring unit through rear, remove knock out and place heater on wall. Mark knockout location on wall. When running conduit or cable to unit through flooring and knock out in bottom of wiring compartment, measure 1-1/2” (38mm) from wall and 2” (51mm) from left end of unit. Cut a 7/8” (22mm) hole in floor centered on the measured location (See Figure 6). Connect the grounding lead to the green ground screw (provided), using a connector. (See Figure 5). Protect electrical supply from kinks, sharp objects, oil, grease, hot surfaces or chemicals. *Distance measured from finished floor surface. Figure 5 Figure 6 Left-end wiring (standard) Ground Screw READ ALL INSTRUCTIONS AND SAFETY INFORMATION. CAUTION - HighTemperature, KeepElectrical Cords, Drapes, And OtherFurnishings AwayFrom Heater WARNING! RISK OF ELECTRICAL SHOCK. TURN OFF ALL POWER AT THE ELECTRICAL PANEL BOARD SUPPLYING POWER TO THE HEATER BEFORE DOING ANY ELECTRICAL WIRING. WARNING! Risk of Fire. Heater must be kept clear of all obstructions: 12” in front and above; 6” on both sides minimum. IMPORTANT! It is extremelyimportant that youverify the electricalsupply wires are thesame voltageas the heater (i.e. 120volt heater to 120 volt power supply and240 volt heater to 240 volt powersupply). If replacingan existing heater, check the labels of the old heater and replace using thesame voltage. Hooking a 240 voltheater to a 120 volt power supply willdrastically reducethe heater’s output. Hooking a 120 voltheater to a 240 volt power supply willdestroy the heater. 8. After confirming heater is level, fasten other end of heater to wall stud with screw to wall. WARNING! Risk of Electrical Shock. Connect grounding lead to grounding wire provided. Keep all foreign objects out of heater. WARNING! Risk of Fire. Heaters must be kept clean of lint, dirt and debris. Failure to follow warnings may cause heater to eject sparks, ignite materials, or cause electrical shock. WARNING! Risk of Electrical Shock. When working with electricity, turn the electrical power off at the electrical panel board and lock or tag the circuit breaker door. Failure to do so could result in serious electrical shock, burns, or possible death! INSTALLATION INSTRUCTIONS STEP 3: Thermostat For best results, use a Cadet electronic wall thermostat or an EBKN end cap DPST thermostat kit. It is recommended that a thermostat be provided for each room. The location of the thermostat should be selected carefully. Thermostats should not be located near drafts from an open doorway or within 18” (45.7cm) of an outside wall, or in direct sunlight or unusual heat sources. A television set or appliance that builds up heat near a thermostat will prevent the thermostat from functioning properly. A wiring diagram illustrating typical wiring of the thermostat is included in the literature provided with the thermostat. Illustrated in Figures 7 thr...

Questo manuale è adatto anche per i modelli :
Elettrico - SOFTHEAT EBHN1000-8 (209.41 kb)
Elettrico - SOFTHEAT EBHN1500-8 (209.41 kb)
Elettrico - SOFTHEAT EBHN500 (209.41 kb)
Elettrico - SOFTHEAT EBHN500-8 (209.41 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie