Log:
valutazioni - 2, GPA: 4.5 ( )

Istruzioni per l'uso Dimplex, Modello CAL150

Produttore : Dimplex
File Size : 239.59 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


However, aged or infirm persons or young children should not be left unsupervised in the vicinity of the heater unless a suitable guard is fitted • IMPORTANT – If this heater is installed in a room containing a bath or shower, it should be so installed that switches and other controls cannot be touched by a person using a bath or shower – to comply with this requirement see ‘Lock the Control Cover’ section on page 2. • If you use this heater in conjunction with an external thermal control, a programme controller, a timer or any other device which switches the heat on automatically, observe all safety warnings AT ALL TIMES since a fire risk exists when the heater is accidentally covered or displaced • The installation of this product should be carried out by an electrician or competent person and be in strict accordance with the current IEE Wiring Regulations and relevant Building Regulations • This heater must not be mounted within 150mm of curtains and other combustible materials or 100mm from a shelf or overhang • NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots at the base of the heater • DO NOT cover the heater – Do not place material or garments on the heater or obstruct the air circulation around the heater • Before connecting the heater check that the supply voltage is the same as that stated on the heater • The heater must be installed in accordance with these instructions • The heater must be mounted using the wall bracket supplied. The heater should only be operated in the upright position • The heater should be positioned in accordance to the clearances stated in these instructions • DO NOT locate this heater immediately beneath a fixed socket outlet General The Calidou radiator is designed to provide exceptional levels of comfort with a combination of radiant and convected heat in both domestic and commercial applications. Wall Mounting / Installation The heater should be positioned observing the minimum clearances stated around the heater. (see also ‘Electrical’ section) The wall bracket supplied with the heater must be used 1. Using a screwdriver, turn the latch in a clockwise direction to unlatch the bracket, then remove it from the appliance (see Fig.1) 2. Mount the bracket on the wall using a minimum of 4 screws (max diameter 6mm) making sure that it is the correct way up and at the correct height. (see Fig.2) 3. Position the appliance on the bracket. 4. Re-latch the bracket turning the latch anti-clockwise. Fig. 2 Fig.1 Model A (mm B (mm) CAL075 140 228 CAL100 300 234 CAL150 400 242 CAL200 700 27 Electrical The wires in the mains lead are colo...

Questo manuale è adatto anche per i modelli :
Elettrico - CAL200 (239.59 kb)
Elettrico - CAL075 (239.59 kb)
Elettrico - CAL100 (239.59 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie