Produttore : Rinnai
File Size : 1.51 mb
File Nome : ES38_1004RFA_Manual.pdf
|
Facilità d'uso
Attach flue adapter to the flue manifold with pipe stopper S. 2. Attach the air inlet hose to the flue manifold. Secure with plastic tie. The unused inlet is plugged with the rubber cap supplied on the manifold. Pipe stopper S Flue Manifold Flue Adapter Inlet elbow Plastic tie Inlet hose 3. Connect the vent sliding tube with pipe stopper S and E. The sliding tube should not be extended beyond the red line. The red line should not be visible after sliding the tube into the vent outlet. Screw Sliding Tube PIPE STOPPER S PIPE STOPPER A Flue Manifold PIPE STOPPER E 4. Slide the insulation sleeve up to the flue manifold and slip the securing clip over the sleeve as shown. 5. Attach the appliance to the wall brackets, using 2 screws at each bracket. SCREW(M5) 6. Attach the back spacer with 3 screws to the top of the appliance. 7. If necessary, the appliance can be leveled using the adjustable legs under the front right and left legs. Rinnai Corporation ES38 Manual Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion WARNING may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. OPERATING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance using the ON/OFF button. 4. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 5. Locate the manual gas valve on the side of the heater. Turn the manual valve clockwise to the full OFF position. Manual Valve CLOSE OPEN 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step. 7. Turn the manual gas valve counterclockwise to the full ON position. 8. Turn on all electric power to the appliance using the ON/OFF button. 9. Set the thermostat to desired setting. 10. Combustion indicator glows red when the burner is lit and flashes when the burner fails to ignite. If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier. See manual for additional information. TO TURN OFF GAS TO APPLIANCE 1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance using the ON/OFF button. 3. Locate the manual gas valve on the side of the heater. Turn the manual valve clockwise to the full OFF position. NOTE: The fan will continue to operate until the appliance is cool. Do not turn the appliance off by unplugging it from the wall. Keep burner and control compartment clean. See installation and operating instructions. Rinnai Corporation ES38 Manual Cut-Away Diagram Rinnai Corporation ES38 Manual Wiring Diagram Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. CAUTION If any of the original wire as supplied with the appliance must be replaced, it must be replaced with type 18 AWG wire or its equivalent. MARK PARTS NAME MARK PARTS NAME MS MAIN SWITCH OH.TH OVER HEATTHERMISTOR R.TH THERMISTOR OHS OVER HEAT SWITCH TF1~3 THERMAL FUSE FM CONVECTION FAN MOTOR F FUSE SP SPARKER ER ELECTRODE SV1~3 MAIN SOLENOID VALVE 1~3 POV MODULATING SOLENOID VALVE BL COMBUSTION FAN MOTOR TR TRANSFORMER PS PRESSURE SENSOR FR1~3 FLAME ROD 1~3 Rinnai Corporation ES38 Manual Ladder Diagram Rinnai Corporation ES38 Manual Parts List For replacement parts call Rinnai at 1-800-621-9419. Rinnai Corporation ES38 Manual Parts List For replacement parts call Rinnai at 1-800-621-9419. Rinnai Corporation ES38 Manual Parts List For replacement parts call Rinnai at 1-800-621-9419. Rinnai Corporation ES38 Manual Parts List For replacement parts call Rinnai at 1-800-62...