• Do NOT overlap combustible materials onto appliance front. • Install combustible materials only up to specified clearances on top, front and side. • Seal joints between the fi nished wall and appliance top and sides using only a 300. F minimum sealant. Fire Risk. Do NOT obstruct air inlet or outlet grilles. Do NOT modify grilles. • Modifying or covering grilles could cause temperature rise and fi re hazard. Finishing materials must not interfere with: • Air fl ow through grilles or louvers. • Operation of louvers or doors. • Access for service. Risk of Fire • Non-combustible clearances MUST be maintained. • Sheetrock, wood or other combustibles must NOT be used as sheathing or facing in the non-combustible zone. • See Section 11 for proper clearances. • See Section 1 for combustible/noncombustible defi nitions. WARNING WARNING WARNING Figure 11.4 A B C Cerona-36 in. 49 16-3/4 43-5/8 mm 1245 425 1108 Cerona-42 in. 45-1/4 16-3/4 50-5/8 mm 1149 425 1286 Note: If using the Apollo Mantel System, the appliance must be raised 1-1/4 in. from fl oor. A B 1 in. (25) C CEILING COMBUSTIBLE SHEATHING NON-COMBUSTIBLE FACING MATERIAL IN SHADED AREAS FIREPLACE ARCH OPENING CLEARANCE TO CEILING MINIMUM BOTTOM OF FIREPLACE TO BOTTOM OF NON-COMBUSTIBLE FACING MATERIAL Figure 11.3 Non-combustible Facing Material A B Cerona-36 in. 43-5/8 50-3/16 mm 1108 1275 Cerona-42 in. 50-5/8 54-3/8 mm 1286 1381 A B NON-COMBUSTIBLE FACING MATERIAL 1 in. (25 mm) Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. H • 11/08 37 C. Finishing Material Options Finishing Material Thickness from 3/4 in. to 1-1/4 in. Finishing material within this thickness range can be brought to 1/2 inch behind the door top and sides. These non-combustible fi nishing materials must never overlap or obstruct the air outlet/inlet grille areas. Figure 11.5 Finishing Material Thickness greater than 1-1/4 inch A steel template (Cerona-36 Template or Cerona-42 Template) is available for purchase to use instead of constructing a template. Non-combustible facing material is supplied with this appliance. This material extends from the header to one inch above the appliance bottom and from framing stud to framing stud. Figure 11.6 Facing Template Dimensions IMPORTANT INSTALLATION Note: Please note that there are four holes or dots on the template to assist in positioning the template. These holes or dots should line up with the door mounting holes on the unit to ensure proper placement of the door after fi nishing materials are installed. A B Cerona-36 in. 43-5/8 50-3/16 mm 1108 1275 Cerona-42 in. 50-5/8 54-3/8 mm 1286 1381 F D C B A R I OH E G A B C D E Cerona-36 in. 34-1/2 23-9/16 5-3/16 1-1/4 38 mm 876 598 132 32 965 Cerona-42 in. 38-7/8 25-1/4 3-5/8 2-5/8 46-1/4 mm 987 641 92 67 1175 F G H I Cerona-36 in. 1-1/4 28-13/16 3/8 34-5/8 mm 32 732 10 879 Cerona-42 in. 2-5/8 31-7/16 3/8 39-5/8 mm 67 799 10 1006 A B HEADER NON-COMBUSTIBLE FINISHING MATERIAL (INSTALLED OVER NON-COMBUSTIBLE FACING MATERIAL) 1 IN. (25 mm) Note: When mounting ATRIMSTONE-36 OR ATRIMSTONE- 42 you must install template or front to insure proper positioning. Failure to do so will result in the front not fi tting (see Figure 11.5). Mounting stone eye brow: ATRIMSTONE-36, ATRIMSTONE-42 38 Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. H • 11/08 Fire Risk. Hearth extension required to protect combustible fl oors in front of appliance. • An 8 inch minimum hearth extension must be constructed of non-combustible material. D. Hearth Extension WARNING Figure 11.9 Hearth Extension Dimensions A B Cerona-36 in. 41-1/8 8 mm 1045 203 Cerona-42 in. 48-1/8 8 mm 1222 203 A B NAILING TABS (BOTH SIDES) NON-COMBUSTIBLE HEARTH EXTENSION 1 in. max. (25 mm) 8 in. min. (203 mm) COMBUSTIBLE SURFACE MARBLE, GRANITE, TILE OR OTHER NON-COMBUSTIBLE HEARTH EXTENSION BOTTOM OF FIREPLACE BOTTOM OF FIREPLACE SURFACE MAY BE COMBUSTIBLE COMBUSTIBLES UP TO 1 INCH THICK ALLOWED UNDER THE OPENING 6 INCHES MINIMUM 1 INCH MAX. TO ALLOW FOR DOOR CLEARANCE Figure 11.7 Position of board and template NON-COMBUSTIBLE BOARD FACING TEMPLATE Figure 11.10 Fireplace sitting on combustible surface. Figure 11.8 Fireplace raised a minimum of 6 inches away from combustible surface. The base of the fi replace may sit on a combustible surface. The area in front of the fi replace must be protected by a noncombustible hearth extension, unless the fi replace is raised a minimum of 6 inches above the combustible fl oor or hearth. See fi gures 11.8 and 11.10. Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. H • 11/08 39 12 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity. C. Accessories Install approved accessories per instructions included with accessories. See Service Parts List for appropriate accessories. Refer to Section 16. Shock or fi re risk. Use ONLY optional ac...
Questo manuale è adatto anche per i modelli :Camini - CERONA-42 (3.9 mb)