Log:
valutazioni - 5, GPA: 4 ( )

Istruzioni per l'uso New Buck Corporation, Modello 34

Produttore : New Buck Corporation
File Size : 1.69 mb
File Nome : f218d192-9bd6-4663-9e91-c5c2b8a7af78.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. 7 CR3329 CERAMIC LOG SET PLACEMENT, FOR MODEL 34 (1-L) (2) (4) (3) (1-R) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. (1) Front Log(s) #1-R and 1-L (Slim Log(s) wrapped in cardboard box) . Place the 1-R between the front portion of the burner and log grates on the right hand side of the log base. Next place 1-L between the front portion of the burner and log grates. Note: logs 1-R and 1-L should over lap in the center of the burner base to create the front log. (2) Middle Glow Log #2 . Place rear of log on top of middle log supports located in open center portion of burner base. Front of log should rest slightly behind the rear line of burner holes on the front portion of the burner. Align the notch on the left front bottom side of the log over the existing hold down nut of the burner. This should align the log at the right position from left or right on the burner. (3) Rear Log #3. Place log in rear log supports center from left to right. (4) Left Top Log #4. Log has two (2) holes in the bottom front side. Align the holes with the two (2) pins located on the left top of log #2. Rear of log #4 should rest on the left top end of the rear log #3. WARNING: POSITIONING OF LOGS IS VERY CRITICAL (SEE DIAGRAM ABOVE). 8 EMBER STOVE LOG SET PLACEMENT FOR MODEL 34 1 2 3 4 5 6 7 “MILLIVOLT ONLY” 1 2 3 4 5 6 7 “MILLIVOLT ONLY” WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. WARNING: POSITIONING OF LOGS IS VERY CRITICAL (SEE DIAGRAM ABOVE). MODEL E.S.B: 1)Rear Log, 2)Middle Log, 3)Left Top Middle Log, 4)Right Top Middle Log 5)Left Front Log 6)Right Front Log 7)Glowing Embers in front of 5 & 6 logs. WARNING: POSITIONING OF LOGS IS VERY CRITICAL (See Figure 2). 1) Place rear log #1 on rear log supports. The log has alignment notches on each rear corner. 2) Place Middle log #2 in front of the rear burner tube and then move the log forward. The log should seat just behind the brass knob(s), located in the middle section of the base between the rear burner tube and the front burner pan. 3) Place Left Top Middle log #3 on the pins located on the left top section of Middle log #2. 4) Place Right Top Middle log #4 on the pin located on the right top section of Middle log #2 and a line the notch on the right side #4 with the side shield on the right. 5) Place Left Front log #5 on the locator pins located on the left middle section of the front burner pan. 6) Place Right Front log #6 on the locator pins located on the right middle section of the front burner pan. 7) Provided with your log set is a package of Glowing Embers (rock wool). Open the package and tare off small pieces of the wool material and place it over the small holes (ports) located on the front burner pan in front of logs #5 and #6. Cover the entire section of holes (ports). *Replacement of loose (Glowing Embers) must be purchased from the original manufacturer and application of excess loose material may adversely affect performance of the heater. NOTE: “Wash your hands immediately after coming in contact with the wool material. The wool can cause slight itching or burning in some cases, avoid any contact with eyes.” “WARNING: All previously applied loose material must be removed prior to replacement.” 9 GAS PRESSURE CHECK Check the inlet pressure to the burner to ensure that it is as shown in the table below. NOTE: The pressure check point is located on the right side of the valve facing burner, for SIT Millivolt, and the left side for SIT Modulating. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa). The appliance must be isolated from the gas supply piping system by closing its equipment shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa). VALVE (MILLIVOLT) (SIT MANUAL-MODULATING) MODEL: FP34 FP34 FP34 FP34 GAS Natural Propane Natural Propane Maximum Heat Input 33,000 33,000 33,000 33,000 Minimum Heat Input 23,000 23,000 12,000 13,000 Gas Inlet Pressure Maximum 10.5ins.W.C. 13ins.W.C. 10.5ins.W.C. 9.0ins.W.C. Minimum * 5.0ins.W.C. *11ins.W.C. *5.0ins.W.C. *11ins.W.C. Manifold Pressure Maximum 3.5ins.W.C. 9.0ins.W.C. 3.5ins.W.C. 9.0ins.W.C. Minimum 3.0ins.W.C. 8.2ins.W.C. 2.8ins.W.C. 7.2ins.W.C. NOTE: On initial installation it may be necessary to...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie