Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Desa, Modello (V)T32EN SERIES

Produttore : Desa
File Size : 1.73 mb
File Nome : 7595f60b-b2f6-edd4-a9bd-09ba4b84e871.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Do not force. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column 1. If you don’t smell gas, go to the next step. 7. Turn equipment shutoff valve counterclockwise to the ON position. Do not force. 8. Close lower louver panel. 9. Turn on all electric power to the appliance. 10. Turn the wall switch to the ON position. 11. Visually locate the pilot. The ignitor should begin to spark and the main burner should ignite once flame appears at pilot. • If lighting the appliance for the first time each season, it may take several attempts before the supply gas can reach the pilot and main burners. • If the appliance will not stay lit after several attempts, follow the instructions To Turn Off Gas To Appliance, page 29, and call your service technician or gas supplier. Adjustment Screw Equipment Shutoff Valve Figure 48 - Turning Equipment Shutoff Valve to the OFF Position Sensing Rod Pilot Burner Ignitor Figure 49 - Pilot TO TURN OFF GAS TO APPLIANCE 1. Turn off the wall switch. 2. Turn off all electric power to the appliance if service is to be performed. 3. Open lower louver panel. 4. Turn equipment shutoff valve clockwise to OFF. Do not force. 5. Close lower louver panel. OPTIONAL REMOTE OPERATION Note: The WRC receiver and hand-held remote control kit must be purchased separately (see Accessories, page 39). Follow installation instructions on page 28. 1. Turn equipment shutoff valve to ON position. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation. 2. Press the ON/OFF button to turn the burner on and off. operating optional blower accessory Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel. The BK manual blower and the BKT thermostatically- controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate. Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases. The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air. OPERATIng fireplace Continued Inspecting Burners Check pilot flame pattern and burner flame patterns often. PILOT Assembly The pilot assembly is factory preset for the proper flame. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner. The flame must envelope 1/4" of top of the ignitor/ sensor and grounding stem. If your pilot assembly does not meet these requirements: • Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 48, page 28). Do not remove the adjustment screw. • see Troubleshooting, page 31 BURNER FLAME PATTERN Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions. If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installation to ensure proper installation and performance. Figure 51 shows a typical flame pattern. If burner flame pattern differs from that described: • turn fireplace off (see To Turn Off Gas to Appliance) • see Troubleshooting, page 31 Sensing Rod Pilot Burner Ignitor/ Sensor Figure 50 - Correct Pilot Flame Pattern Figure 51 - Typical Flame Pattern Cleaning and Maintenance WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc. GLASS DOOR WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken. WARNING: Do not use abrasive cleaners as this may damage glass. Use a nonabrasive household glass cleaner to clean glass. Do not clean glass when hot. Glass must be cleaned periodically. During start- up it is normal for condensation...

Questo manuale è adatto anche per i modelli :
Camini - (V)T32EP SERIES (1.73 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie