|
Facilità d'uso
WARNING: FIREPLACES EQUIPPED WITH OPTIONAL ACCESSORY DOORS SHOULD BE OPERATED ONLY WITH THE DOORS FULLY OPEN OR FULLY CLOSED (FIGURE 4 ). THIS APPLIANCE MAY ONLY BE FITTED WITH DOORS CERTIFIED FOR USE WITH THE APPLIANCE. AVERTISSEMENT: POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIEES AVEC L'APPAREIL. Fully Open or Fully Closed Figure 4 DAMPER AND COMBUSTION AIR CONTROLS This appliance is fitted with a manually controlled vent damper. The vent damper should be closed when the appliance is not in use to prevent cold air from entering the home through the venting system. The damper is controlled through the use of a control lever located within the appliance opening at the top center in front of the firebox lintel (see Figure 5). The control lever snaps into place at either extreme of its range of motion. When locked in position all the way to the right, the damper is open. When locked in position all the way to the left, the damper is closed. The damper lever actuates a switch, (see wiring diagram) which will prevent the appliance main burner from lighting unless the damper is locked open. The appliance flue damper must always remain open when operating. WARNING: DAMPER MUST BE IN OPEN POSITION WHEN APPLIANCE MAIN BURNER IS OPERATING. AVERTISSEMENT: LE REGISTRE DOIT ETRE EN POSITION OUVERTE LORSQUE LE OU LES BRULEURS PRINCIPAUX DE L'APPEREIL FONCTIONNMENT. Damper Closed Damper Open Lintel Outside Air Actuator Figure 5 Many appliances are equipped when installed with an outside (make-up) air vent system that is designed to provide the appliance with outside make-up air for combustion when in operation. The actuator for the outside air system is standard on all appliances but must not be operated if the complete system is not installed. Refer to Figure 6. When the complete outside air vent system is installed, the installer will remove the actuator locking screw. If your screw is not removed and you have reason to believe that you have a complete outside air system, contact your distributor to have your appliance inspected for the presence of the complete system. DO NOT assume that you have this system in place because you have an actuating lever present on your appliance front face. 5NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 6 Pull the actuator forward to open the combustion air door, and push it back to close. To "lock" the combustion air door closed, ensure the actuator is pushed all the way back, then push the end of the actuators to the right until the step in the actuator moves behind the appliance front face within the slotted opening. MANUALLY-RESET BLOCKED FLUE SAFETY SWITCH This appliance is equipped with a manually- reset blocked flue safety switch. Refer to Figure 7 for its location. If during appliance operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the operation of this safety limit switch. First allow the appliance to cool, then reset the safety switch by pushing the red reset button on the back of the switch. CAUTION: THE ELECTRONIC APPLIANCE SHOULD BE TURNED OFF BEFORE REMOV- ING THE LIMIT SWITCH. To access the safety limit switch reset button, remove the screen rod and screen from the right side of the fireplace. Unscrew two screws and remove the limit switch with low voltage wires attached. Push the reset button, then reinstall the limit switch. Reinstall the screen and rod. At this time turn the electronic appliance back on. The appliance should then relight and remain lit. If this does not occur, turn off the appli- ance and call a qualified service technician. Remove Locking Screw and “Pop” Actuator to theLeft Before Initial Use Combustion Air Actuator Pull Forward to Open, Push Back to Close Figure 7 Limit Switch Screws Manual Reset Limit Switch Screen Rod Lintel Extension Right Side Refractory Panel Screen To provide outside combustion air to your appliance while it is in operation, locate the combustion air actuator along the right side of the appliance opening (Figure 5). To operate, push the end of the actuator to the left as shown in Figure 6, until it "pops" free of its "locked" position. WARNING: DO NOT OPERATE THE COM- BUSTION AIR ACTUATOR UNLESS A COMPLETE OUTSIDE AIR VENT SYS- TEM HAS BEEN INSTALLED WITH YOUR APPLIANCE. Maintenance The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service technician. Proper maintenance and use will require more frequent, less extensive inspections and servicing by the homeowner. Generally, annual inspections should be performed by a qualified service technician. More frequent periodic inspections and cleanings should be performed by the homeowner. Any discrepancies discovered by the homeowner should result in a call to a qualified service technician to effect the repair or correction. Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they should be performed. IM...
Questo manuale è adatto anche per i modelli :Camini - Merit Series LMBV-42REN (2.9 mb)
Camini - Merit Series LMBV-42RMN (2.9 mb)