Log:
valutazioni - 4, GPA: 3.8 ( )

Istruzioni per l'uso Napoleon Fireplaces, Modello Castlemore GDS26P

Produttore : Napoleon Fireplaces
File Size : 3.99 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Slip a minimum of 2" of the 4" flexible vent pipe over the inner sleeve of the air terminal. Secure to the inner sleeve using 3 screws. Seal the joint and screw heads using the high temperature sealant W573-0002 (not supplied). NOTE: If using pipe clamps to connect vent components, 3 screws must also be used to ensure the connection cannot slip off. 2. Slip the first section of 7" rigid vent pipe a minimum of 2" over the outer sleeve of the air terminal. Secure to the outer sleeve using 3 screws. Seal the joint and screw heads using high temperature sealant W573-0002 (not supplied). 3. Insert the vent pipe through the firestop / vent pipe shield. Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall. Make weather tight by sealing with caulking (not supplied). 4. If more than one length of vent pipe needs to be used to reach the stove, couple them together as illustrated in FIGURE 25. Seal the joints using the same procedure as described above. The air terminal mounting plate may be recessed into the exterior wall or siding by 1.", the depth of the return flange. SCREWS #10 x 2" SEALANT HIGH TEMPERATURE 2" OVERLAP VENT PIPE 4"FLEXIBLE CAULKING VENT PIPE 7" RIGID ATTENTIONCHAUDCAUTION - HOT FIGURE 24 SCREWS & WASHERS 4" COUPLER SELF DRILLING#8x1/2" 7" RIGID VENT PIPE 4" FLEXIBLE VENT PIPE 7" RIGID VENT PIPE HIGH TEMPERATURE FIGURE 25 SEALANT W415-0607 / A / 01.18.08 18 W415-0607 / A / 01.18.08 RESTRICTING VERTICAL VENTS Vertical termination installations exiting either from the rear or the top flue collar of the stove may display a very active flame. If this appearance is not desirable, the vent exit must be restricted to reduce the velocity of the exhaust gases, thus slowing down the flame pattern and creating a more traditional gentle appearance. Remove the baffl e plate from the rear wall of the fi rebox, exposing the fl ue gas outlet opening. Superimpose this outlet hole with the smaller hole on the kit restrictor plate. Secure with the two screws provided and replace the baffl e plate. VERTICAL VENTING INSTALLATION 1. Follow the instructions for "Horizontal Air Terminal Installations", items 1 to 3. 2. Continue adding components alternating fl exible and rigid vent pipes. Ensure that all 4" fl exible vent pipes and elbows have suffi cient vent spacers attached and each component is securely fastened to the one prior. Attach the 4" telescopic sleeve to the vent run. Repeat using a 7" telescopic sleeve. Secure and seal as before. To facilitate completion, attach 4" and 7" couplers to the air terminal. 3. Install the air terminal. See item 3 of the Horizontal Air Terminal Installation. Extend the 4" telescopic sleeve; connect to the air terminal assembly. Fasten with self tapping screws and seal. Repeat using the 7" telescopic sleeve. FIGURE 26 EXTENDED HORIZONTAL AND CORNER AIR TERMINAL INSTALLATION 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 2. Stretch the 4" fl exible vent pipe to the required length. Slip the vent pipe a minimum of 2” over the inner pipe of the air terminal connector and secure with 3 #8 screws. Seal using a heavy bead of the high temperature sealant W573-0002 (not supplied). NOTE: If using pipe clamps to connect vent components, 3 screws must also be used to ensure the connection cannot slip off. 3. Slip the 7" rigid vent pipe a minimum of 2" over the air terminal connector and secure with 3 #8 screws. Seal using a heavy bead of the high temperature sealant W573-0002 (not supplied). 4. Thread the air terminal connector / vent pipe assembly down through the roof. The air terminal must be located vertically and plumb. Attach the air terminal connector to the roof support, ensuring that the top of the air terminal is 16” above the highest point that penetrates the roof. If the attic space is tight, we recommend threading the Wolf Steel vent pipe collar or equivalent loosely onto the air terminal connector / vent pipe assembly as it is passed through the attic. The air terminal connector must be located vertically and plumb. 5. Remove nails from the shingles, above and to the sides of the chimney. Place the fl ashing over the air terminal connector leaving a min. 3/4” of the air terminal connector showing above the top of the fl ashing. Slide the fl ashing underneath the sides and upper edge of the shingles. Ensure that the air terminal connector is properly centred within the fl ashing, giving a 3/4” margin all around. Fasten to the roof. Do not nail through the lower portion of the fl ashing. Make weather-tight by sealing with caulking. Where possible, cover the sides and top edges of the fl ashing with roofi ng material. 6. Aligning the seams of the terminal and air terminal connector, place the terminal over the air terminal conn...

Questo manuale è adatto anche per i modelli :
Camini - Castlemore GDS26N (3.99 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie