Log:
valutazioni - 5, GPA: 4.4 ( )

Istruzioni per l'uso Napoleon Fireplaces, Modello UVFRC-4228

Produttore : Napoleon Fireplaces
File Size : 1.06 mb
File Nome :
Lingua di insegnamento:
Vai a scaricare



Facilità d'uso


Example Example Coordinate in ()Example Canopy Combustible Mantel and Trim Clearance Figure 5 Combustible Mantel and Trim Clearance Model UVF-36 WITH Canopy Installed Canopy is required on all installations for this model only. EXAMPLE: If you choose to install a mantel that projects 5", you will need to install it so that the bottom of the mantel and trim is approximately 13" or more above Firebox opening (see coordinate in shaded area above). EXAMPLE: If you choose to install a mantel that projects 4", you will need to install it so that the bottom of the mantel and trim is approximately 13" or more above Firebox opening (see coordinate in shaded area above). Models UVFRC-3628 and UVFRC-4228 WITH Canopy Installed Canopy is optional on these models 16” 9-1/2” 2”3”4”5”6” 10” 11” 12” 13” 14” 15” Top of Firebox Opening Screen Top of Appliance Combustible Mantel and Trim Header Top Spaceron Appliance Safe Zone Canopy Non-Combustible Material 3” Min. Example Example Coordinate in ()Example Combustible Material (wall) Figure 4 16” 17” 18” 9” 3”4”5”6”7“8” 10” 11” 12” 13” 14” 15” Top of Firebox Opening Screen Top of Appliance Combustible Material (wall) Combustible Mantel and Trim Header Top Spacer on Appliance Safe Zone Non-Combustible Material 3” Min. Example Example Coordinate in ()Example Canopy Combustible Mantel and Trim Clearance 23” 24” 16” 6”7”8”10” 9” 17” 18” 19” 20” 21” 22” Top of Firebox Opening Screen Top of Appliance Combustible Mantel and Trim Header Top Spacer on Appliance Safe Zone Non-Combustible Material 3” Min. Example Example Combustible Material (wall) Coordinate in ()Example Models UVFRC-3628 and UVFRC-4228 WITHOUT Canopy Installed Canopy is optional on these models Combustible Mantel and Trim Clearance EXAMPLE: If you choose to install a mantel that projects 7", you will need to install it so that the bottom of the mantel and trim is approximately 19" or more above Firebox opening (see coordinate in shaded area above). Figure 6 Noncombustible material (minimum requirements) with wood mantel or other combustible projections: To install the firebox with a wood mantel, shelf or other combustible projection above firebox opening. Refer to Figures 4, 5 & 6. WARNING The canopy must be in place to be in compliance with the clearances specifi ed in Figures 4 & 5. Do not remove or replace canopy, only use canopy supplied or offered for these fi reboxes (see Pages 16 & 17). Do not use any canopy which may be provided with the decorative type Vent-Free room heater. If your mantel profile is unsafe, you may either: • Raise the mantel to an acceptable height, or • Remove the mantel. Floor clearance: These fireplaces may sit directly on a combustible surface. The appliance should be mounted on a fully supported base extending the ful...

Questo manuale è adatto anche per i modelli :
Fans - UVFRC-3628 (1.06 mb)
Fans - UVFRC-3628 (1.06 mb)
Camini - UVFRC-3628-H (1.06 mb)
Camini - UVF-36 (1.06 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie