|
Facilità d'uso
Min inlet pressure : 5 11 in w.c. Max inlet pressure : 7 14 in w.c. Vent size : 4” Diam. listed gas liner Valve : Natural gas Propane White Rogers Robertshaw Model 36C03U TYPE 139 Model 7000 MVRLC Millivolt operated Millivolt operated SIT SIT Nova model Nova model Millivolt operated Millivolt operated Blower : Variable speed, 140 CFM Thermo-switch : 120° F “ON” 110° F “OFF” bi-metal type Efficiency : 74% heating Clearances to combustibles : mantel : 10” from top of face place side wall : 0” from side of face plate TOP, SIDE AND FRONT VIEWS : INSTALLATION : 1. When the masonry fireplace that will receive the ULTRA FLAME gas insert is thoroughly cold, remove all ashes and vacuum clean. 2. Remove the glass front from the gas insert following page 11 instructions. 3. Remove the burner and firebox bottom plate from the gas insert following page 12 instructions. 4. Remove the draft hood from the top of the appliance. 5. Move the ULTRA FLAME to the desired position and level the appliance using the two bolts located in the back corners. Mark the location for the gas inlet pipe. ( We suggest using the hole in the back of the ULTRA FLAME for ease of connection. ) 6. Remove the ULTRA FLAME gas insert from the fireplace. 7. Route a 3/8” minimum NPT iron pipe gas line to the desired location. 8. If you wish to make a direct electrical connection to the blower without using the six foot cord supplied, route a 120 volts, 60 Hz electrical power supply line to the same location. 9. Remove or block open the masonry fireplace flue damper. 10. Install a certified 4” gas liner inside the chimney from its very top down to the fireplace. 11. Secure the liner to the 4” connector on the top of the ULTRA FLAME with three metal screws. 12. Push the ULTRA FLAME back in the fireplace while pulling the draft hood in place. To do so, fix two ropes to the draft hood sliders. Make sure the draft hood front lip is squeezed under the steel angle to prevent any motion. The probe tube must go through the top of the appliance tube accessible by opening the top front grill. When the hood is in its location, fix it with 2 screws in the prepunched holes. 13. Install a 1/8” NPT plugged tapping for test gauge connection immediately upstream of the gas supply connection to the appliance. 14. Install a shutoff valve to the gas line. Tighten securely using a pipe joint compound. 15. Install a 3/8” flex connector to connect the shutoff valve to the gas valve on the fireplace. Tighten securely using a pipe joint compound. 16. Check the gas line piping for leaks. Use a soap and water solution. WARNING : DO NOT USE OPEN FLAME TO CHECK LEAKS. 17. If you decided to make a direct connection to the fan step 8, remove the power cord and connect the 120 V line. To do so, unscrew the speed control unit and pull away from the junction box a few inches. Unscrew the two mar connectors attached to the cord (P) and the cord ground. Remove the cord and route the supply line through the same holes. Make the electrical connection with the same wires the cord was attached to. Screw the ground wire to the junction box (G). If you prefer to use the six foot cord supplied, just connect it to a 120 V outlet. 18. If you want to turn the main burner ON and OFF using a wall switch : - Install the wall switch in a convenient location. Route a proper sized wire from the switch or the thermostat to the gas valve. Distance between valve Wire gage and switch 8’ 22 12’ 20 20’ 18 32’ 16 50’ 14 - Connect the wires in serial with the face plate flame switch ( green wires ). NOTE : DO NOT CONNECT THE WALL SWITCH WIRE OR THE VALVE TO 120 VOLTS POWER SUPPLY LINE. THE VALVE IS OPERATED BY ITS OWN MILLIVOLT SYSTEM. 19. If you want to turn the main burner ON and OFF using a wireless remote control, install the remote control module apart from the gas valve and as close to the front as possible. Connect the wires as shown. 20. Install the firebox bottom plate and burner following page 12 instructions. 21. Install the 4 logs on the burner as shown on page 13. 22. If so desired, install the embers kits as shown on page 16. 23. Install the glass front following page 11 instructions. 24. Install the face plate according to page 14 instructions. 25. Install a cap on the liner. 26. Install a flashing on top the chimney to seal around the liner and to prevent water infiltration. GLASS FRONT REMOVAL CLEANING AND INSTALLATION : * To remove the glass front, unscrew the six screws holding it in place as shown. CAUTION : Hold the glass while unscrewing to prevent it from falling. * Clean the glass only with liquid cleaners or soaps and water, do not use abrasive cleaners which could remove the coating on the glass. WARNING : Do not clean when hot, turn off the fireplace at least 30 minutes before removing the glass front. * The glass used on your fireplace is a high temperature ceramic 5 mm thick with a speci...
Questo manuale è adatto anche per i modelli :Camini - 36C03U TYPE 139 (166.93 kb)
Camini - 7000 MVRLC (166.93 kb)
Camini - 7000 MVRLC (166.93 kb)