|
Facilità d'uso
Be sure to release air pressure from the gas line before connection is made totheappliance.Excessivepressurewilldamagethegas control and may cause a gas leak. • GasLeakTest:Makesurethegasconnectionsaretight. Turn on the gas and coat each joint with a non-corrosive gas leak check solution. Air bubbles will form indicating any leaks. DO NOT USE A FLAME OR ANY TYPE OF IGNITION SOURCE TO CHECK FOR LEAKS. All leaks must be corrected before proceeding with installation. 0 Quadra-Fire • Fogata Grande October 2006 C. Gas Connection Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter.) Note: A listed (and Commonwealth of Massachusetts approved) 1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. WARNING Fire Risk Explosion Risk • Gas build-up during line purge may ignite. • Purge should be performed by qualified technician. • Ensure adequate ventilation. • Ensuretherearenoignitionsourcessuch as sparks or open flames. • Incoming gas line should be piped to the 1/2 in. connection. • Theapplianceanditsindividualshutoffvalvemustbe disconnectedfromthegassupplypipingsystemduring any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). • A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from lines. Subsequent lighting of the log set will not require such purging. WARNING CHECK FOR GAS LEAKS Fire Risk Explosion Risk Asphyxiation Risk • Check all fittings and connections. • Do not use open flame. • Afterthegaslineinstallationiscomplete, all connections must be tightened and checked for leaks with a commercially available, non-corrosive leak check solution.Besuretorinseoffallleakcheck solution following testing. Fittingsandconnectionsmayhaveloosened during shipping and handling. D. High Altitude Installations OMNI gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 ft in the USA and Canada. When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility. If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities. Quadra-Fire • Fogata Grande October 2006 6 Operating Instructions A. Before Lighting Appliance • Beforelightingthisappliance,ensure themanualshutoff valve is open. Before operating this appliance, have a qualified technician: • Inspect the burner before each use of the gas log set. If thereisany evidence thattheburner isdamaged,itmust be replaced before operating. • Review proper placement of logs. • Ensure that there are no gas leaks. • Ensure that the flow of combustion and ventilation air is not obstructed. WARNING Improper installation, adjustment, alteration, service or maintenancecancauseinjuryorpropertydamage.Refer to the owner’s information manual provided with this appliance.Forassistanceoradditionalinformationconsult a qualified installer, service agency or the gas supplier. WARNING Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. WARNING • • • • Fire Risk Burn Risk HOT! DO NOT TOUCH. SEVERE BURNS MAY RESULT. CLOTHING IGNITION MAY RESULT Glass and other surfaces are hot during operation and cool down. Keep children away. CAREFULLYSUPERVISEchildreninsameroomas appliance. Alert children and adults to hazards of high temperatures. Keep clothing, furniture, draperies and other combustibles away. On/Off Switch Piezo Valve Control Knob WARNING The lighting instructions and operation of the unit are describedonthefollowinginstructionalpageandMUSTbe followed to ensure the safe operation of this appliance. 2 Quadra-Fire • Fogata Grande October 2006 LIGHTING INSTRUCTIONS MILLIVOLT VALVE 1. STOP! Read the safety information previously listed above. 2. Turn gas control handle clockwise • to the ‘OFF” position. 3. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step. 4. ...
Questo manuale è adatto anche per i modelli :Camini - FOGATAGRANDE FG21SP-LP (2.46 mb)